Chapter 2: Installation
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Supply Fail
UID/Overheat (OH)/Fan Fail
Connect an LED cable to UID/OH/Fan Fail connections on pins 7 and 8 of JF1 to provide
front UID LED indication and warnings of overheating or fan failure. Refer to the tables below
for pin definitions.
UID/OH/Fan Fail LED
Pin Definitions (JF1)
Pin#
Definition
7
Front UID LED
8
OH/Fan Fail LED
OH/Fan Fail Indicator
Status (JF1)
State
Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
Power Button
UID LED
NIC1 Active LED
Reset Button
HDD LED
PWR LED
Reset
PWR
UID SW
3.3V LAN
Ground
19
X
Ground
X
3.3V LAN
20
1
2
Ground
Power Fail LED
NIC2 Active LED
NMI
3.3V
OH/Fan Fail LED
3.3V
1. Power Fail LED
2. OH/Fan Fail LED
3. Front UID LED
1
2
3