![Supermicro X11SCV-L Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/supermicro/x11scv-l/x11scv-l_user-manual_1404093037.webp)
37
Chapter 2: Installation
Overheat (OH)/Fan Fail
Connect an LED cable to OH/Fan Fail connections on pins 7 and 8 of JF1 to provide warnings
for chassis overheat/fan failure. Refer to the table below for pin definitions.
OH/Fan Fail Indicator
Pin Definitions
Pins
Definition
Off
Normal
On
Overheat
Flashing
Fan Fail
OH/Fan Fail LED
Pin Definitions (JF1)
Pins
Definition
7
Vcc/Blue UID LED
8
OH/Fan Fail LED
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins
11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC
LED cables to NIC1 and NIC2 LED indicators to display network activities. Refer to the table
below for pin definitions.
LAN1/LAN2 LED
Pin Definitions (JF1)
Pins
Definition
9/11
+3.3V Stby
10/12 NIC Activity LED
OH/Fan Fail LED
20
NIC1 Activity LED
19
HDD LED
FP PWRLED
3.3V Stby
3.3V
3.3V
X
Ground
NMI
X
NIC2 Activity LED
3.3V Stby
3.3V Stby
Power Button
Reset Button
Reset
PWR
Ground
Ground
1
2
X
3.3V
1. HDD LED
2. NIC1 Activity
3. NIC2 Activity
1
2
3