49
Chapter 3: Maintenance and Component Installation
Figure 3-15. Removing a Dummy Drive from the Carrier
Note:
Enterprise level hard disk drives are recommended for use in Supermicro chassis and
servers. For information on recommended HDDs, visit the Supermicro website at
https://www.
supermicro.com/en/products/system/1U/1029/SYS-1029U-TN12RV.cfm
Hot-Swap for NVMe Drives
An NVMe drive can be inserted and replaced using IPMI.
Note
: If you are using VROC, see the VROC appendix in this manual instead.
Ejecting a Drive
1.
IPMI > Server Health > NVMe SSD
2. Select Device, Group and Slot, and click
Eject
.
After ejecting, the drive Status LED
indicator turns green.
3. Remove the drive.
Note that
Device
and
Group
are categorized by the CPLD design architecture. The
1029U-TN12RV server has one Device and one Group.
Slot
is the slot number on which the NVMe drives are mounted.