Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful in...
Страница 3: ...drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product s...
Страница 4: ...Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 Installing the Rail...
Страница 5: ...36 Installing Expansion Cards 36 Motherboard Battery 37 3 4 Chassis Components 38 Hard Drives 38 Hard Drive Carrier Indicators 39 DVD ROM Drive Installation 39 System Fans 41 System Fan Failure 41 Re...
Страница 6: ...64 5 4 IPMI 65 Chapter 6 UEFI BIOS 6 1 Introduction 66 Starting the Setup Utility 66 6 2 Main Setup 67 6 3 Advanced Setup Configurations 69 6 4 Event Logs 103 6 5 IPMI 105 6 6 Security 108 6 7 Boot 1...
Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...
Страница 8: ...n any way If any equipment appears damaged please file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated...
Страница 9: ...to 2TB ECC 3DS LRDIMM 512GB ECC RDIMM DDR4 up to 2666MHz Chipset Intel C621 chipset Expansion Slots Two PCI E 3 0 x16 slots Two PCI E 3 0 x16 slots or 4 PCI E 3 0 x8 by MUX Four PCI E 3 0 x8 slots One...
Страница 10: ...being supplied to the system s power supply units This LED should normally be illuminated when the system is operating 7 Reset Button The reset button is used to reboot the system 8 Power Button The m...
Страница 11: ...3 SATA3 Drive Bays 9 FDD Tray One FDD tray 10 11 Drive Bay Two 5 25 drive bays 12 DVD Tray One slim DVD ROM Drive 13 Control Panel For details see the previous section Figure 1 2 Chassis Front View Fr...
Страница 12: ...iency 94 AC DC power supplies with PMBus 2 I O Ports I LAN USB LAN VGA described in Chapter 4 3 PCI E 3 0 Slot PCI E 3 0 x4 in x8 slot 4 PCI E 3 0 Slots PCI E 3 0 x8 and x16 slots described in Chapter...
Страница 13: ...S LICENSE SAN MAC MAC CODE BAR CODE PCH IPMI CODE BMC FAN1 FANA FANB JL1 JPI2C1 FAN6 COM1 SP1 BT1 USB 0 1 IPMI_LAN JUIDB1 JSDCARD1 LEDBMC LED2 VGA P1 DIMMA1 P1 DIMMA2 P1 DIMMC1 P1 DIMMB1 P1 DIMME1 P1...
Страница 14: ...for CPU2 JIPMB1 4 pin BMC External IC Header for an IPMI card JL1 Chassis Intrusion Header JNCSI1 NC SI Header for IPMI Support JNVI2C1 NVMe SMBus I2 C headers used for PCI E hot plug SMBus clock dat...
Страница 15: ...wer pin Built in w support of SuperDOM Disk On Module S SGPIO Serial Link General Purpose I O Header SP1 Internal Speaker Buzzer USB 0 1 Back Panel USB 2 0 Ports USB 2 3 Front Access USB 2 0 Headers U...
Страница 16: ...0 x8 CPU1 Slot 4 PCIE 3 0 x16 SPI FLASH 32MB BIOS BMC SPI MUX PCH SPI SPI FLASH 32MB BMC DDR4 VGA NC SI RMII EXT CONN JNCSI1 UL1 PHY RTL8211E COM1 IPMI LAN RJ45 TPM Header S SATA0 S SATA1 I SATA 0 3 I...
Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...
Страница 18: ...er from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always ke...
Страница 19: ...ion should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in...
Страница 20: ...g hardware provided You should also refer to the installation instructions that came with the specific rack you are using Identifying the Rails The rack rails and the related hardware should have been...
Страница 21: ...using Installing the Inner Rack Rails Installing the Inner Rails 1 Place the inner rack extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes 2 Slide t...
Страница 22: ...d a long bracket to the rear side of the right outer rail 3 Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack 4 Secure the short bracket to t...
Страница 23: ...ls 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely into the rac...
Страница 24: ...hut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord...
Страница 25: ...25 Chapter 3 Maintenance and Component Installation Figure 3 1 Removing the Chassis Cover Release Tab 1 1 1 2 1 1...
Страница 26: ...bel area of the CPU or socket The processor and heatsink should be assembled together first to form the Processor Heatsink Module PHM and then install the entire PHM into the CPU socket When receiving...
Страница 27: ...w 3 Align pin 1 of the CPU with pin 1 of the narrow processor clip Once they are aligned carefully insert the CPU into the processor clip by sliding notch B of the CPU into notch B of the processor cl...
Страница 28: ...socket Dual Socket P LGA 3647 and a back plate Figure 3 4 CPU Socket with Dust Cover On Removing the Dust Cover from the CPU Socket Remove the dust cover from the CPU socket exposing the socket pins...
Страница 29: ...at diagonal corners of the PHM onto the two guide posts on the socket bracket and carefully lower the PHM onto the socket 4 Use a T30 Torx bit screwdriver to install four screws into the mounting hol...
Страница 30: ...oosen and remove the screws on the PHM from the socket starting with the screw marked 4 in the sequence of 4 3 2 1 2 Pull up the PHM while releasing the small snap tabs on two corners of the socket Pr...
Страница 31: ...el Two DIMMs per Channel 4 Gb 8 Gb 1 2 Volts 1 2 Volts RDIMM SRx4 8 GB 16 GB 2666 2666 SRx8 4 GB 8 GB 2666 2666 DRx8 8 GB 16 GB 2666 2666 DRx4 16 GB 32 GB 2666 2666 RDIMM 3Ds QRX4 N A 2H 64GB 2666 266...
Страница 32: ...xed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in the sa...
Страница 33: ...PUs 2 DIMMs CPU1 P1 DIMMA1 CPU2 P2 DIMMA1 2 CPUs 4 DIMMs CPU1 P1 DIMMA1 P1 DIMMD1 CPU2 P2 DIMMA1 P2 DIMMD1 2 CPUs 6 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8...
Страница 34: ...Server 6039P TXRT User s Manual 34 CPU1 P2 DIMMA1 P2 DIMMA2 P2 DIMMD2 P2 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIMMB1 P2 DIMMC1 P1 DIMMD2 CPU2 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 P1 DIMMA2 P1 DIMMA1 P1 DIMMB1 P1 DI...
Страница 35: ...utwards on both ends of the DIMM slot to unlock it 3 Align the key of the DIMM module with the receptive point on the memory slot 4 Align the notches on both ends of the module against the receptive p...
Страница 36: ...Push the tab toward the drive and push the drive unit out the front of the chassis 4 Re use the side rails or install the side rails onto the peripheral drive 5 Insert the new drive unit in the slot u...
Страница 37: ...the holder with the positive side facing up Then push the other side down until the clamp snaps over it 5 Secure the expansion card shield onto the rear of the chassis with a screw PCIe Slot Processor...
Страница 38: ...Secure the drive to the carrier with the screws provided then push the carrier completely into the drive bay You should hear a click when the drive is fully inserted This indicates that the carrier h...
Страница 39: ...tus indicator lights to indicate the status of the drive In non RAID configurations the status indicator remains off DVD ROM Drive Installation The 6039P TXRT accommodates only slim DVD drives Side mo...
Страница 40: ...of the chassis 4 Add a new drive by following this procedure in reverse order You may hear the faint click of the locking tab when the drive is fully inserted 5 Reconnect the data and power cables to...
Страница 41: ...which of the fans has failed Replacing System Fans Removing a Fan System power does not need to be removed since the fans are hot pluggable Replace the failed fan with an identical 8 cm 12 volt fan av...
Страница 42: ...SuperServer 6039P TXRT User s Manual 42 Figure 3 12 Replacing a Rear Fan...
Страница 43: ...ay the chassis on a flat stable surface and remove the chassis cover 2 If necessary move any cables that interfere with the air shroud placement 3 Place the air shroud in the chassis The air shroud fi...
Страница 44: ...t without powering down the system Replacing the Power Supply You do not need to shut down the system to replace a power supply unit The backup power supply module will keep the system up and running...
Страница 45: ...d in Chapter 1 Please review the Safety Precautions in Appendix B before installing or removing components 4 1 Power Connections Four power connections on the X11DPX T must be connected to the power s...
Страница 46: ...ns Internal Buzzer Pin Definitions Pin Definition 1 Pos Beep In 2 Neg Alarm Speaker Warning To provide adequate power to your system and to avoid damaging the power sup ply or the motherboard be sure...
Страница 47: ...I carrier card to function properly please purchase the appropriate IFP cable from Supermicro Please refer to Supermicro s website at www supermicro com for the part number of the IFP cable specified...
Страница 48: ...MOSI 8 N A 9 JTPM1_P3V3A 10 IRQ_TPM_SPIN_N TPM Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from a third party vendor A TPM Port 80 connector is...
Страница 49: ...r pin definitions Power SMB Header Pin Definitions Pin Definition 1 Clock 2 Data 3 Power Fail 4 Ground 5 3 3V I SATA 3 0 and S SATA 3 0 Ports The X11DPX T has eight I SATA 3 0 ports I SATA0 3 I SATA4...
Страница 50: ...and cable installed Also JNVI2 C1 and JNVI2 C2 are VPP headers for NVMe add on cards See the table below for pin definitions NVMe SMBus Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4...
Страница 51: ...icro at www supermicro com to purchase the cable for this header Refer to the table below for pin definitions NC SI Header for IPMI Support Pin Definitions Pin Definition Pin Definition 1 CLK_50MHz 2...
Страница 52: ...0 Ground Figure 4 1 JF1 Control Panel Pins Control Panel JF1 contains header pins for various control panel connections See the figure below for the pin locations and definitions of the control panel...
Страница 53: ...is located on pins 19 and 20 of JF1 Refer to the table below for pin definitions NMI Button Pin Definitions JF1 Pin Definition 19 NMI 20 Ground Power LED Pin Definitions JF1 Pin Definition 15 Vcc 16...
Страница 54: ...nition 5 3 3V 6 PWR Supply Fail Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configu...
Страница 55: ...0 Port 4 8 LAN Port 2 4 USB 3 0 Port 5 9 VGA Port 5 USB 2 0 Port 0 1 5 4 3 2 6 7 8 9 VGA Port One VGA port is located next to LAN Port 2 on the I O back panel Use this connection for VGA display Seria...
Страница 56: ...nition Pin Definition 1 VBUS 10 Power 2 D 11 USB 2 0 Differential Pair 3 D 12 4 Ground 13 Ground of PWR Return 5 StdA_SSRX 14 SuperSpeed Receiver 6 StdA_SSRX 15 Differential Pair 7 GND_DRAIN 16 Ground...
Страница 57: ...ication of a system unit that may be in need of service Note UID can also be triggered via IPMI on the motherboard For more information on IPMI please refer to the IPMI User s Guide posted on our webs...
Страница 58: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...
Страница 59: ...o bypass SPI flash security and force the system to use the Manufacturing Mode which will allow you to flash the system firmware from a host server to modify system settings See the table below for ju...
Страница 60: ...1 Gbps Dedicated IPMI LAN Activity LED LED State Right Color Status Definition Amber Flashing Active LAN 1 LAN 2 IPMI LAN X8ST3 F Link LED Activity LED LAN 1 2 LEDs Two LAN ports LAN 1 LAN 2 are loca...
Страница 61: ...Color State Definition Green Blinking BMC Normal Onboard PWR LED Indicator LED States Color State Definition Off System Off PWR cable not connected Green On System Power On Onboard Power LED An Onboa...
Страница 62: ...USB port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper...
Страница 63: ...1 should appear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and uti...
Страница 64: ...nagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...
Страница 65: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...
Страница 66: ...used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options...
Страница 67: ...Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS f...
Страница 68: ...SuperServer 6039P TXRT User s Manual 68 Memory Information Total Memory This item displays the total size of memory available in the system...
Страница 69: ...feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal P...
Страница 70: ...d EFI Boot Install Windows 7 USB support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA optical...
Страница 71: ...voltage control during processor idle states Select Enabled to decrease the system power by throttling CPU frequency when one power supply is failed The options are Disabled and Enabled CPU Configura...
Страница 72: ...website for detailed information PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Disable and Unlock Enable Hardware Prefetc...
Страница 73: ...Mode Available when Power Performance Tuning is set to BIOS Controls EPB The Energy Performance BIAS EPB feature allows the user to configure CPU power and performance settings Select Maximum Performa...
Страница 74: ...tive Mode with No Legacy Support CPU C State Control Available when Power Technology is set to Custom Autonomous Core C State Use this feature to enable the autonomous core C State control The options...
Страница 75: ...mation will be displayed Number of CPU Number of IIO Current UPI Link Speed Current UPI Link Frequency UPI Global MMIO Low Base Limit UPI Global MMIO High Base Limit UPI Pci e Configuration Base Size...
Страница 76: ...nd the recent memory reads are likely to miss the LLC a speculative read is sent to the local memory controller The options are Disable and Enable KTI Prefetch KTI Prefetch is a feature that enables m...
Страница 77: ...ce Detect and implement into memory RC code to improve system reliability Select Disable for TCCD to follow Intel POR The options are Disable and Auto Enable ADR Select Enable for ADR Automatic Diagno...
Страница 78: ...able to support the UEFI based address range mirroring with setup option The options are Disable and Enable Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to impro...
Страница 79: ...ecide how many hours the system should wait before the next complete patrol scrub is performed Use the keyboard to enter a value from 0 24 The Default setting is 24 IIO Configuration IIO Configuration...
Страница 80: ...cally set the maximum payload value for a PCI E device to enhance system performance The options are 128B 256B and Auto CPU1 SLOT4 PCI E 3 0 x16 Link Speed Use this feature to select the link speed fo...
Страница 81: ...he system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance The options are 128B 256B and Auto CPU2 Configuration IOU0 IIO PCIe Br1 This item configu...
Страница 82: ...nce The options are 128B 256B and Auto CPU2 SLOT8 PCI E 3 0 x16 Link Speed Use this feature to select the link speed for the PCIe port The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s...
Страница 83: ...are operating with a common clock source PCI E Port Max Payload Size Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance Th...
Страница 84: ...Enable and Disable PassThrough DMA Select Enable to use the Non Isoch VT_D engine pass through DMA support The options are Enable and Disable ATS Select Enable to use the Non Isoch VT_D engine ATS su...
Страница 85: ...x16 VMD Available when the device is detected by the system Select Enable to use the Intel Volume Management Device Technology for this device The options are Disable and Enable Hot Plug Capable Avail...
Страница 86: ...root ports 1A 1D The op tions are Disable and Enable VMD Config for PStack1 Intel VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack Th...
Страница 87: ...formation will be displayed USB Module Version USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select Auto to disable legacy support if there are no legacy USB devi...
Страница 88: ...ty of the Azalia controller The op tions are Disabled and Enabled Server ME Configuration This feature displays the following system ME configuration settings Operational Firmware Version Backup Firmw...
Страница 89: ...enable a SATA port specified by the user The options are Disable and Enable Spin Up Device SATA Port 0 Port 7 On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The...
Страница 90: ...e and Enable Spin Up Device SATA Port 0 Port 7 On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable and Enable SATA Device Type SATA Port 0 Por...
Страница 91: ...edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are Disable and Enable sSATA Device Type sSATA Port 0 Port 1 Use this item to specify if the SATA port speci...
Страница 92: ...le sSATA Device Type sSATA Port 0 Port 1 Use this item to specify if the SATA port specified by the user should be connected to a Solid State drive or a Hard Disk Drive The options are Hard Disk Drive...
Страница 93: ...other option AMI Native Support is offered by the BIOS with a generic method VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot The optio...
Страница 94: ...v4 HTTP Support Select Enabled to enable Ipv4 HTTP boot support The options are Disabled and Enabled Ipv6 PXE Support Select Enabled to enable Ipv6 PXE boot support The options are Disabled and Enable...
Страница 95: ...8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Serial Port 2 Configuration This submenu allows the user the configure settings of Serial Port 2 Serial Port 2 Select Enabled to enable the sele...
Страница 96: ...acters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that t...
Страница 97: ...d Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows...
Страница 98: ...ssion speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirecti...
Страница 99: ...pad used for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable leg...
Страница 100: ...use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits Per second This item sets the transmission speed for a serial port used in Console...
Страница 101: ...d button is activated The options are Suspend Disabled and S3 Suspend to RAM Trusted Computing Available when a TPM device is installed and detected by the BIOS Security Device Support If a Trusted Pl...
Страница 102: ...ision Support Enabling this feature will lock your TPM Once locked the NV indexes will not be able to be deleted The options are Disabled and Enabled TXT Support Intel TXT Trusted Execution Technology...
Страница 103: ...Enabled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Ye...
Страница 104: ...s that a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass...
Страница 105: ...irmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings...
Страница 106: ...system boot The options are No and Yes If the item above is set to Yes the following items will become available for user s configuration Configuration Address Source This feature allows the user to...
Страница 107: ...This item displays the IPMI LAN setting The default setting is Enabled If the item above is set to Enabled the following items will become available for user s configuration Configuration Address Sou...
Страница 108: ...20 characters long User Password Press Enter to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Pas...
Страница 109: ...re Disabled and Enabled Key Management This submenu allows the user to configure the following Key Management settings Provision Factory Defaults Select Enabled to install the default Secure Boot keys...
Страница 110: ...e from the manufacturer s defaults to the existing DB The default setting is Set New Forbidden Signatures Forbidden Signature Database DBX contains forbidden certificates and digital signa tures Selec...
Страница 111: ...e the EFI boot support The options are Disabled and Enabled FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry fro...
Страница 112: ...to the boot priority features for your system Add Boot Option Use this item to specify the name for the new boot option Path for Boot Option Use this item to enter the path for the new boot option in...
Страница 113: ...abled Hard Disk Drive BBS Priorities This feature allows the user to specify the boot device priority from the available hard disk drives Boot Option 1 The options are the available hard disk drive an...
Страница 114: ...and Reset After completing the system configuration changes select this option to save the changes you have made This will reset reboot the system Save Changes When you have completed the system conf...
Страница 115: ...lect Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User D...
Страница 116: ...ntinue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps...
Страница 117: ...com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnost...
Страница 118: ...the Advanced tab Use the arrow keys and press Enter to select Chipset Configuration North Bridge IIO Configuration Intel VMD technology Intel VMD for Volume Management Device on CPU to access the menu...
Страница 119: ...ure has become available Note 1 The license and header on the motherboard for Intel VROC hardware key are required Also be sure the version of Intel Rapid Storage Technology enterprise Intel RSTe VROC...
Страница 120: ...x16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device NVMe Device Processor Intel VMD x16 PCIe Intel VMD x16 PCIe Intel VMD x16 PCIe NVMe Device NVMe Device NVMe Device N...
Страница 121: ...Refer to the instructions stated in E 1 section on how to access All Intel VMD Controllers menu items Follow the steps below to create RAID volume s Step 1 To create RAID volume s use the arrow keys t...
Страница 122: ...enter the unique name of the RAID volume Step 3 RAID Level This item allows the user to select the RAID level The options are RAID0 Stripe RAID1 Mirror RAID5 Parity and RAID10 RAID0 1 Note The RAID le...
Страница 123: ...ts Step 4 Enable RAID spanned over VMD Controller The options are not selected and X selected Set this item to X if the RAID level you selected earlier from Step 3 will cross VMD domains Note For a bo...
Страница 124: ...by one to X to select the desired RAID disks Step 6 Strip Size Use this item to select the RAID strip size The options are 4KB 8KB 16KB 32KB 64KB and 128KB Note For RAID0 RAID1 RAID5 RAID10 the minimu...
Страница 125: ...25 Appendix B Standardized Warning Statements Step 7 Capacity MB This item allows the user to enter the desired RAID capacity in MB See the right panel of the screen for the maximum volume size allowe...
Страница 126: ...XRT User s Manual Step 8 Create Volume Use the arrow keys to select Create Volume Press Enter to create a RAID level with settings shown on the screen Refer to the following for the RAID volume s bein...
Страница 127: ...Standardized Warning Statements RAID Volumes For detailed RAID volume information use the arrow keys to select the desired RAID volume as shown below RAID VOLUME INFO Press Enter and the following scr...
Страница 128: ...te On the RAID VOLUME INFO screen use the arrow keys to select Delete and press Enter to delete the RAID volume you have selected earlier see the previous page for the RAID volume selection The follow...
Страница 129: ...screen select the desired NVMe device from the list of RAID Member Disks Press Enter and the following screen will appear The item Reset to non RAID allows the user to remove RAID data from the selec...
Страница 130: ...efer to the instructions stated in E 1 section on how to access All Intel VMD Controllers menu items When the following screen appears select the desired NVMe device from the list of Non RAID Physical...
Страница 131: ...Use the arrow keys to select Mark as Spare and press Enter The following screen will appear Options are Yes and No Note A spare disk is used for automatic RAID volume rebuilds when status of failed m...
Страница 132: ...sk Refer to the instructions stated in E 1 section on how to access All Intel VMD Controllers menu items When the following screen appears select the desired NVMe device from the list of Non RAID Phys...
Страница 133: ...th a power drive failure crash while writing RAID5 strips The use of journal disk that contains partial parity logging PPL can reduce the potential data loss Refer to the following illustration for th...
Страница 134: ...D Press Enter and the following screen will appear Step 2 Use the arrow keys to select RWH Policy RWH is a scenario related to a power drive failure crash Step 1 Refer to the instructions stated in E...
Страница 135: ...isable Note 1 Partial parity logging PPL can be defined as the result of XOR calculation of old data and old parity PPL is a feature available for RAID5 volumes While a power drive failure crash occur...
Страница 136: ...e item RWH Policy to Journaling Drive Press Enter and the RWH JD feature will become available as shown below RWH JD Use the arrow keys to select RWH JD Press Enter and the following screen will appea...
Страница 137: ...take effect use the arrow keys to select Change RWH settings and press Enter The user will be returned to the main screen of All Intel VMD Controllers as shown below Step 4 Use the arrow keys and pres...
Страница 138: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 139: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 140: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 141: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 142: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 143: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 144: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 145: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 146: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 147: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 148: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 149: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 150: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 151: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 152: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 153: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 154: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 155: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 156: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 157: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 158: ...ds off management to a computer during system boot D 2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The recovery bloc...
Страница 159: ...oo large due to the huge volumes of folders and files stored in the device To perform UEFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the...
Страница 160: ...f you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key...
Страница 161: ...om the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the set...
Страница 162: ...nterrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power s...
Страница 163: ...s 3 0 x16 slots Two PCI Express 3 0 x16 slots or four PCI E 3 0 x 8 by MUX Four PCI Express 3 0 x8 slots One PCI Express 3 0 x4 in x8 slot Motherboard X11DPX T Proprietary form factor 15 12 x 13 2 in...
Страница 164: ...11 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlo...