SuperServer 6029U-T Series User's Manual
54
Figure 3-16. Ultra Riser and Expansion Cards
Figure 3-17. Ultra Riser and Expansion Cards with Optional Storage Drives
Optional Cage for Two Storage Drives
Страница 1: ...USER S MANUAL Revision 1 0 SuperServer 6029U T Series...
Страница 2: ...perated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may caus...
Страница 3: ...ties and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities ftp ftp supermicro com Product safety info http www supermic...
Страница 4: ...for Service 17 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerations 19 Ambient...
Страница 5: ...the CPU Socket for Installation 34 Installing the Processor Heatsink Module 35 Memory 36 Memory Support 36 DIMM Population Requirements 36 Memory Installation 40 Motherboard Battery 41 3 4 Chassis Co...
Страница 6: ...ndows to a Non RAID System 69 5 2 Driver Installation 70 5 3 SuperDoctor 5 71 5 4 IPMI 72 Chapter 6 BIOS 6 1 Introduction 73 Starting BIOS Setup Utility 73 6 2 Main Setup 73 6 3 Advanced Setup Configu...
Страница 7: ...permicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information s...
Страница 8: ...Description Part Number Quantity Power supply modules PWS 1K02A 1R 2 Backplane BPN SAS3 826A N4 1 Fans FAN 0118L4 4 Air Shrouds MCP 310 82921 0N MCP 310 82922 0N 1 each Heatsinks SNK P0068PS 2 Riser c...
Страница 9: ...size up to 128 GB at 1 2 V Chipset Intel C621 Expansion Slots Two full height double width PCIe slots one x8 one x16 four full height full width x8 PCIe slots one low profile x8 PCIe slot one interna...
Страница 10: ...server but maintains standby power 2 Reset button Reboots the system 3 Power LED Indicates power is being supplied to the system power supply units This LED is illuminated when the system is operating...
Страница 11: ...t environment Blinking blue Remote UID is on This indicator can be activated using IMPI from a remote location Chassis Front The illustration below shows the features included on the front of the chas...
Страница 12: ...n the left PWS2 on the right 2 LAN Two or four LAN ports depending on your Ultra riser card see Section 1 1 Overview for details also see LAN numbering description below 3 USB Two USB 3 0 ports 4 IPMI...
Страница 13: ...JNVI2C2 T SGPIO3 BP PWR2 BP PWR4 BP PWR3 BP PWR1 PSU1 PSU2 P1_NVMe1 P1_NVMe0 JNVI2C1 GPU PWR1 SXB3A SXB3B SXB3C SP1 BT1 JBT1 JRK1 JWD1 JVRM1 SXB1C SXB1B SXB1A SXB2 GPU PWR2 GPU PWR4 GPU PWR3 JSD1 JSD...
Страница 14: ...cable are required available only for Supermicro complete systems JRK1 RAID_Key for onboard NVMe devices JSD1 JSD2 SATA DOM power connectors 1 2 JSDCARD1 Micro SD card slot JTPM1 Trusted Platform Modu...
Страница 15: ...y Module P1_D2 Solid Red Memory Error LED_P1_E1 LED_P1_E2 Memory Fault LEDs for Memory Module P1_ E1 Memory Module P1_E2 Solid Red Memory Error LED_P1_F1 LED_P1_F2 Memory Fault LEDs for Memory Module...
Страница 16: ...nternal M 2 NVMe Slot optional part 2 PCIe x8 Slots PCIe x8 Slot NVMe Drive bays 8 9 optional part NVMe Drive bay 11 opt part PCIe x8 Slot PCIe x16 Slot NVMe Drive bay 10 opt part SATA Drive bays 0 11...
Страница 17: ...be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is compl...
Страница 18: ...ck Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas wher...
Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 20: ...ply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special pr...
Страница 21: ...installation instructions that came with the specific rack you are using Identifying the Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail t...
Страница 22: ...completely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer...
Страница 23: ...r rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the qu...
Страница 24: ...ter rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the pr...
Страница 25: ...Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely...
Страница 26: ...us for a single person to remove it from the rack Have sufficient personnel or use a lift to support the chassis 1 Pull the chassis forward out the front of the rack until it stops 2 Press the release...
Страница 27: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...
Страница 28: ...hese two screws are optional and will not impact functionality if they are not installed 2 Press the two release buttons and slide the cover toward the rear and lift off Check that all ventilation ope...
Страница 29: ...handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or CPU socket whi...
Страница 30: ...nual 30 Overview of the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the processor Heatsink with Thermal Grease Processor Carrier Processor P...
Страница 31: ...w 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3...
Страница 32: ...carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the a...
Страница 33: ...tion This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remo...
Страница 34: ...ws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tightening...
Страница 35: ...1 2 V 1 2 V RDIMM SRx4 8 GB 16 GB 2666 2666 RDIMM SRx8 4 GB 8 GB 2666 2666 RDIMM DRx8 8 GB 16 GB 2666 2666 RDIMM DRx4 16 GB 32 GB 2666 2666 RDIMM 3Ds QRX4 N A 2H 64GB 2666 2666 8RX4 N A 4H 128GB 2666...
Страница 36: ...DIMM1 Config Set A DIMM0 DIMM1 Config Set B DIMM0 DIMM1 Config Set C Possible Mixes DIMM0 DIMM1 Within IMC DIMM Population DDR0 x8 None x8 x8 x4 None x4 x4 x8 x4 or x4 x8 Single Rank None Single Rank...
Страница 37: ...x8 DIMMs DDR Channel 0 1 2 DIMM0 is populated with identical DIMMs DDR Channel 0 1 DIMM1 is populated with identical DIMMs 1 SVLS 6 x8 DIMMs Populate 2 DIMMs per DDR channel x SVLS DIMM Population wit...
Страница 38: ...IMM Population within an IMC Note Non equal in rank pair of x4 DIMMs 1 pair of DIMMs DDR0 Populate with 1 DIMM DDR1 Populate the second DIMM for best performance 1 Y 2 pairs of DIMMs DDR0 Populate wit...
Страница 39: ...IMMA1 push the release tabs outwards on both ends of the DIMM slot to unlock it Press both notches straight down into the memory slot Notches Release Tabs 2 Align the key of the DIMM with the receptiv...
Страница 40: ...lacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the...
Страница 41: ...storage SBB HDDCompList pdf Figure 3 4 Optional NVMe SAS Drive Bays Drive Carrier Indicators Each drive carrier has two LED indicators an activity indicator and a status indicator In RAID configurati...
Страница 42: ...ving a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the ch...
Страница 43: ...gn the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to the carrier with four M3 screws as...
Страница 44: ...are supported 42mm 60mm 80mm or 110mm For each length there is an hole in the storage adapter card for a plastic standoff The following combinations are supported Two 42 or 60 mm One 42 and one 80 mm...
Страница 45: ...ard Then push it flat against the adapter card and the plastic standoff 6 Secure the SSD by firmly inserting the standoff plug 7 Replace the RSC UMR 8 storage adapter card and the WIO riser card Stand...
Страница 46: ...led fans can be identified through the IPMI Changing a System Fan 1 Determine which fan has failed using IPMI or if necessary open the chassis while the system is running Never run the server for long...
Страница 47: ...flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating...
Страница 48: ...lling the Air Shroud Air shrouds concentrate airflow to maximize fan efficiency The serverboard air shroud does not require screws to install Installing the Air Shroud Position the air shroud as illus...
Страница 49: ...ar of the power supply module an LED displays the status Solid Green When illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in a...
Страница 50: ...Manual 50 3 Pull the module out using the handle 4 Push the new power supply module into the power bay until it clicks Replace with the same model 5 Plug the AC power cord back into the module Figure...
Страница 51: ...ngth x16 CPU1 x8 CPU1 TR4 T All other models 3 Internal low profile half length x8 CPU1 All models but TR4 T 4 Low profile half length x8 CPU2 All models 5 Full height full length x8 CPU2 All models 6...
Страница 52: ...ard bracket pictured above On the rear of the chassis each bracket is secured by a small black plastic flip switch with an arrow on it Flip open the appropriate switch to release the bracket then pull...
Страница 53: ...nd Riser Cards Front View 4 Replace the riser card into the motherboard expansion slot while aligning the bracket into the chassis Flip the black plastic switch back in place making sure it snaps clos...
Страница 54: ...SuperServer 6029U T Series User s Manual 54 Figure 3 16 Ultra Riser and Expansion Cards Figure 3 17 Ultra Riser and Expansion Cards with Optional Storage Drives Optional Cage for Two Storage Drives...
Страница 55: ...ponent Installation Internal Expansion Card For most models the Ultra riser card that holds the LAN ports also offers another internal low profile card slot 4 for Supermicro SAS only Installation is p...
Страница 56: ...d at PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate power to the motherboard connect the both main pow...
Страница 57: ...HFI1 JHFI2 on the motherboard The JHFI headers are used when the F model processor is installed Use an HFI sideband cable to connect the carrier card to the JHFI headers and use an appropriate IFP Int...
Страница 58: ...wer to a solid state DOM storage devices connected to one of the SATA ports DOM Power Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground Trusted Platform Module Port 80 Header Pin Definitions Pin D...
Страница 59: ...ement Bus header for IPMI 2 0 is located at JIPMB1 Connect a cable to this header to use the IPMB I2 C connection on your system External I2 C Header Pin Definitions Pin Definition 1 Data 2 Ground 3 C...
Страница 60: ...o SD memory card into the expansion slot at JSDCARD1 for additional memory or OS image RAID Key Header Pin Definitions Pin Definition 1 Ground 2 RAID_KEY_PU 3 Ground 4 PCH_RAID_KEY NVMe SMBus Headers...
Страница 61: ...nd Key Power On LED Control signal HDD LED Activity signal NIC1 LED Ground NIC2 LED Ground OH Fan Fail LED Ground Power Fail LED Ground Ground Ground 2 1 20 19 Power Button Pin Definitions JF1 Pin Def...
Страница 62: ...Blue LED 8 OH Fan Fail LED LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Con...
Страница 63: ...nection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 NM...
Страница 64: ...on the chassis rear provided by the Ultra add on card depending on the model There is also a dedicated IPMI LAN port on the I O back panel For more information on IPMI refer to the IPMI User s Guide...
Страница 65: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...
Страница 66: ...Watch Dog is a monitor that can reboot the system when a software application hangs Jumping pins 1 2 will cause Watch Dog to reset the system if an application hangs Jumping pins 2 3 will generate a...
Страница 67: ...on and off Be sure to turn off the system and unplug the power cord s before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Off power cable not connected...
Страница 68: ...iption Status LED_P1_A1 A2 Memory Fault LEDs for Memory Module P1_A1 A2 Red on memory errors LED_P1_B1 B2 Memory Fault LEDs for Memory Module P1_B1 B2 Red on memory errors LED_P1_C1 C2 Memory Fault LE...
Страница 69: ...er cables Supermicro SuperDOMs are backward compatible with regular SATA HDDs or SATA DOMs that need external power cables NVM Express Connections Four NVM Express ports are located on the motherboard...
Страница 70: ...SB port on the system Note for older legacy OS s please use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper dr...
Страница 71: ...er option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities to your hard dr...
Страница 72: ...Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Serve...
Страница 73: ...rm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...
Страница 74: ...ption is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list...
Страница 75: ...b key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears...
Страница 76: ...this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the nor...
Страница 77: ...cal drive as a USB drive USB CD DVD drives are not supported Disable this feature after the XHCI driver has been installed in Windows The options are Disabled and Enabled Port 61h Bit 4 Emulation Sele...
Страница 78: ...cessor Max Ration Processor Min Ration Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor 0 Version Processor 1 Version Hyper Threading All Available when supported by the CPU Select...
Страница 79: ...rformance The options are Enable and Disable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes if this feature is set to Disable The CPU prefet...
Страница 80: ...in the system The options are HW_ALL SW_ALL and SW_ANY Turbo Mode Available when Intel EIST Technology is enabled Select Enable to use the Turbo Mode to boost system performance The options are Disabl...
Страница 81: ...Bridge This feature allows the user to configure the following North Bridge settings UPI Configuration UPI Configuration The following information will be displayed Number of CPU Number of IIO Curren...
Страница 82: ...ation Integrated Memory Controller iMC Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage programming The options are POR and Disable Memory Frequency Use this feature...
Страница 83: ...tions are Disable and Enable Memory Rank Sparing Select Enable to enable memory sparing support for memory ranks to improve memory performance The options are Disable and Enable If the item above Memo...
Страница 84: ...lt setting is 24 IIO Configuration IIO Configuration EV DFX Features When this feature is set to Enable the EV_DFX Lock Bits that are located on a proces sor will always remain clear during electric t...
Страница 85: ...hance system performance The options are 128B 256B and Auto P1_NVMe1 Link Speed Use this feature to select the link speed for the PCIe port The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8...
Страница 86: ...Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Max Payload Size Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance syst...
Страница 87: ...XT NVME5 Available when the device is detected by the system Link Speed This feature allows the user to select PCI E support for the device installed in the system The options are Auto Gen 1 2 5 GT s...
Страница 88: ...ction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU2 IIO PCIe Br3 This item configures the PCI E port Bifuraction setting for a PCI E port...
Страница 89: ...tus PCI E Port Link Max PCI E Port Link Speed PCI E Port Max Payload Size Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performanc...
Страница 90: ...the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI Tables This feature offers fully protected I O resource sharing across Intel platforms providing greater reliabilit...
Страница 91: ...the Intel Volume Management Device Technology for this de vice The options are Disable and Enable Hot Plug Capable Available when the device is detected by the system Use this feature to enable the h...
Страница 92: ...the device is detected by the system Select Enable to use the Intel Volume Management Device Technology for this device The options are Disable and Enable AOC URN6 i2XT NVME5 VMD Available when the de...
Страница 93: ...for PCIe root ports 1A 1D The op tions are Disable and Enable VMD Config for PStack1 Intel VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this...
Страница 94: ...e options are Enabled Disabled and Auto XHCI Hand off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI ownership cha...
Страница 95: ...ill return to normal when the I O becomes active The options are Disable and Enable If the item above Configure SATA as is set to AHCI the following items will be displayed SATA Port 0 Port 7 This ite...
Страница 96: ...e installed SATA drive on the particular SATA port Model number of drive and capacity Software Preserve Support Hot Plug SATA Port 0 Port 7 Select Enabled to enable a SATA port specified by the user T...
Страница 97: ...ble a SATA port specified by the user The options are Disable and Enable Spin Up Device sSATA Port 0 Port 5 On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The op...
Страница 98: ...CI Bus Driver Version PCI Devices Common Settings Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4...
Страница 99: ...ptions are Onboard and Offboard RSC UMR 8 SLOT1 PCI E x8 OPROM RSC UMR 8 M 2_PCIe OPROM Select Disabled to deactivate the selected slot Legacy to activate the slot in legacy mode and EFI to activate t...
Страница 100: ...s will be displayed Ipv4 PXE Support Select Enabled to enable Ipv4 PXE boot support The options are Disabled and Enabled Ipv4 HTTP Support Select Enabled to enable Ipv4 HTTP boot support The options a...
Страница 101: ...IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Serial Port 2 Configuration This submenu allows the user the configure settings of Serial Port 2 Serial Port 2 Select Enabled to enable the select...
Страница 102: ...haracters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits Per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure tha...
Страница 103: ...nded terminal resolution support The options are Disabled and Enabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy...
Страница 104: ...nd Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission...
Страница 105: ...ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy console redirection after BIOS POST When this feature is set to BootLoader legacy console redirection is disabl...
Страница 106: ...Make sure that the same speed is used in both host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits...
Страница 107: ...etting to take effect The options are Disable and Enable If the item above is set to Enable the following items will become available for user s configuration The following Platform Configuration Regi...
Страница 108: ...s and ensures protection confidentiality and integrity of data stored or created on the system Use this feature to enable or disable TXT Support The options are Disabled and Enabled iSCSi Configuratio...
Страница 109: ...bled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Ev...
Страница 110: ...ces that a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pas...
Страница 111: ...mware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Er...
Страница 112: ...to Yes the following items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static i...
Страница 113: ...d If the item above is set to Enabled the following items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP addres...
Страница 114: ...sword Press Enter to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup fo...
Страница 115: ...abled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Enroll all Factory Default Keys Select Yes to install all default secure keys set by the manu...
Страница 116: ...idden Signatures Forbidden Signature Database DBX contains forbidden certificates and digital signa tures Select Set New to load the DBX from the manufacturer s defaults Select Append to add the DBX f...
Страница 117: ...to enable the EFI boot support The options are Disabled and Enabled FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each e...
Страница 118: ...on Use this feature to remove a pre defined boot device from which the system will boot during startup The options are Select one to Delete and UEFI Built in EFI Shell UEFI Application Boot Priorities...
Страница 119: ...nd Exit from the Exit menu and press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will reset reboot the syst...
Страница 120: ...em stability but not for maximum performance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the...
Страница 121: ...s you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the followi...
Страница 122: ...rmicro com support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a di...
Страница 123: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...
Страница 124: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 125: ...rken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...
Страница 126: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 127: ...ntes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l ins...
Страница 128: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 129: ...kabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment W...
Страница 130: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 131: ...o a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...
Страница 132: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 133: ...t aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...
Страница 134: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 135: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...
Страница 136: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 137: ...nale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accor...
Страница 138: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 139: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...
Страница 140: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 141: ...ur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...
Страница 142: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 143: ...te Model TR4T is different see pg 50 Input Output per node Network Two to four LAN ports varies by model IPMI Dedicated LAN port USB 3 0 Two ports on the rear I O panel USB 0 1 One serial port one VGA...
Страница 144: ...4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlorate Warning California Best Management Practice...
Страница 145: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...
Страница 146: ...a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our websi...
Страница 147: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...
Страница 148: ...boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Buil...
Страница 149: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...
Страница 150: ...is purpose you can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interfa...
Страница 151: ...m remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellanous tab then the Trouble...