USER’S MANUAL
Revision 1.0a
SuperServer
®
6029BT-DNC0R
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 6029BT DNC0R...
Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...
Страница 3: ...and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp Product safety info http www superm...
Страница 4: ...ard Layout 14 Quick Reference 15 Chapter 2 Server Installation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considera...
Страница 5: ...Heatsink Module 30 Preparing the CPU Socket for Installation 31 Installing the Processor Heatsink Module 32 Memory Installation 33 Memory Support 33 Memory Population Guidelines 34 Memory Population...
Страница 6: ...62 5 3 SuperDoctor 5 63 5 4 IPMI 64 Chapter 6 BIOS 6 1 Introduction 65 Starting BIOS Setup Utility 65 6 2 Main Setup 65 6 3 Advanced Setup Configurations 67 6 4 Event Logs 93 6 5 IPMI 95 6 6 Security...
Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...
Страница 8: ...below Main Parts List Description Part Number Quantity Power supply PWS 2K22A 1R 2 Fans FAN 0162L4 4 Heatsink SNK P0068PS SNK P0069PS 2 each Air shroud MCP 310 21717 0B 2 PCIe Riser Card RSC P2 88 2 R...
Страница 9: ...e DIMM NV DIMM and Intel Optane DC Persistent Memory DCPMM up to four slots Chipset Intel C621 Expansion Slots per node Two PCIe 3 0 x8 Full height 6 6 long One PCIe 3 0 x16 low profile Storage Drives...
Страница 10: ...re used to locate the server in large racks and server banks Information LED Status Description Continuously on and red An overheat condition has occurred This may be caused by cable congestion Blinki...
Страница 11: ...node A with a motherboard 3 Power Supplies Redundant power modules 4 PCI Slots Two full height PCIe x8 slots in each node 5 PCI Slots One low profile PCIe x16 slot in each node 6 SIOM port Network po...
Страница 12: ...IB FDR Two QSFP two RJ45 AOC MHIBF m2Q2GM One QSFP two RJ45 AOC MHIBF m1Q2GM Updates https www supermicro com support resources AOC AOC_Compatibility_SIOM cfm Input Output Ports Figure 1 4 Rear I O P...
Страница 13: ...13 Chapter 1 Introduction Figure 1 5 Node Drawer Node Trays The chassis contains two separate computing nodes each with its own motherboard...
Страница 14: ...JSDCARD1 I SATA6 JTAG1 JCPLD1 JRK1 BT1 JBT1 JF1 JF2 JNVI2C1 JTPM1 JSD1 CPU1 PCI E 3 0 X4 CPU2 PCI E 3 0 X24 I SATA0 5 P2 DIMMF2 P2 DIMMF1 P2 DIMMD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P...
Страница 15: ...ufacturer use only JTPM1 Trusted Platform Module TPM Port 80 connector JVRM1 VRM header SIOM CPU1 PCIe 3 0 x16 slot for proprietary add on module use SXB1 PCIe 3 0 x4 x4 slot supported by CPU1 and SAT...
Страница 16: ...el C621 Chipset Block Diagram Single Node To PCI E Expansion Slots 2 PCI E x8 To PCI E Expansion Slot To NVMe SATA M 2 slots SYS 6029BT DNC0R System Block Diagram Single Node BCM 3008 To SAS3 drive ba...
Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...
Страница 18: ...ver from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always k...
Страница 19: ...onnections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precaut...
Страница 20: ...g Note This rail will fit a rack between 28 and 33 5 deep Overview of the Rack Rails The package includes two rail assemblies Each is specifically designed for the left or right side of the chassis an...
Страница 21: ...ecure the rail to the rack with screws 3 Pull out the rear section of the outer rail adjusting the length until it fits within the posts of the rack and align the small hooks with the appropriate hole...
Страница 22: ...e the unit out for servicing Failure to stabilize the rack can cause the rack to tip over Chassis Installation Slide the chassis into the rack so that the bottom of the chassis slides onto the bottom...
Страница 23: ...ase follow the procedures given in each section 3 1 Removing Power Before performing some setup or maintenance tasks use the following procedure to ensure that power has been removed from the system R...
Страница 24: ...2 Accessing the System Removing a Computing Node Drawer 1 Use the operating system to power down the node 2 Remove any cables attached to the node 3 Push the release latch to the right then pull the...
Страница 25: ...as fans by removing the cover Removing the Chassis Cover The chassis top cover can be lifted off after removing two screws Caution Except for short periods of time do not operate the server without th...
Страница 26: ...t and none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation or s...
Страница 27: ...tenance and Component Installation SNK P0068PS SNK P0069PS Heatsinks There are two different heatsink models SNK P0068PS and SNK P0069PS not as tall Use the SNK P0069PS for CPU2 in each node Figure 3...
Страница 28: ...ule The Processor Heatsink Module PHM contains a heatsink a processor carrier and the processor Note that there are two different heatsink models SNK P0068PS and SNK P0069PS not as tall Heatsink with...
Страница 29: ...ing the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3 Exami...
Страница 30: ...carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the...
Страница 31: ...tion This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remo...
Страница 32: ...he heatsink on top 3 With a T30 Torx bit screwdriver gradually tighten screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the pro...
Страница 33: ...M 3Ds QRX4 N A 2H 64GB 8RX4 N A 4H 128GB LRDIMM QRx4 32 GB 64 GB LRDIMM 3Ds QRx4 N A 2H 64GB 8Rx4 N A 4H 128 GB DDR4 Memory Support for 82xx 62xx 52xx 42xx 32xx Processors Type Ranks Per DIMM and Data...
Страница 34: ...ixed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in the s...
Страница 35: ...1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMM...
Страница 36: ...E 3 0 X4 CPU2 PCI E 3 0 X24 I SATA0 5 P2 DIMMF2 P2 DIMMF1 P2 DIMMD1 P2 DIMME1 P2 DIMME2 P2 DIMMD2 P2 DIMMC2 P2 DIMMC1 P2 DIMMA1 P2 DIMMA2 P2 DIMMB1 P2 DIMMB2 P1 DIMMF2 P1 DIMMF1 P1 DIMMC1 P1 DIMMC2 CP...
Страница 37: ...M3 DCP M3 DCP DCP M3 DCP M3 M3 2 2 1 4 DCP 8 DIMM AD DCP M1 M1 M1 M1 DCP 1 1 1 MM DCP M1 M1 M1 M1 DCP 1 1 1 AD MM DCP M3 M3 M3 M3 DCP 1 1 1 4 DCP 16DIMM AD DCP M1 M1 M1 M1 M1 M1 M1 M1 DCP 2 2 1 AD Ap...
Страница 38: ...population use the same DDR4 DIMM in all slots For each individual population sockets are normally symmetric with exceptions for one DCPMM per socket and one DCPMM per node case Currently DCPMM module...
Страница 39: ...power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release T...
Страница 40: ...acing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the h...
Страница 41: ...r Indicators Each drive carrier has two LED indicators an activity indicator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive In non RAID c...
Страница 42: ...board Each node controls a set of six drives If a node drawer is pulled out of the chassis the drives associated with that node will power down Node Drawer Locations Node A controls drives A1 A6 Node...
Страница 43: ...ton on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the carrier out of the chassis Figure 3 7 3 Remove the dummy drive from the carrier Figure 3 8 Caution Except fo...
Страница 44: ...he mounting holes in the drive align with those in the carrier 2 Secure the hard drive into the carrier with the screws Figure 3 10 Installing the Hard Drive 3 Insert the drive and carrier into its ba...
Страница 45: ...rted 42mm 60mm 80mm or 110mm For each length there is an hole in the storage adapter card for a plastic standoff SSD Sockets Hole for Standoffs choose one Installing an M 2 SSD Look at the storage ada...
Страница 46: ...he adapter card into the JF1 SXB1 SXB2 JF2 slots on the motherboard and replace the mounting screws 7 Replace the node into the chassis and power up If the plastic standoff is not in the correct hole...
Страница 47: ...CI shields and slide the cage to the right looking at the chassis rear 3 Remove the blank PCI shield from the chassis 4 Slide the expansion card shield into the open shield slot while plugging the exp...
Страница 48: ...motherboard This installation is usually performed by a system integrator or manufacturer Installing the SIOM Card Before Installing the Motherboard 1 Insert the SIOM card into the motherboard as show...
Страница 49: ...Card After the Motherboard Is Installed 1 With the node pulled out remove the eight screws as below Figure 3 17 Removing the Rear Node Section for SIOM Figure 3 16 Rear Node Section Screws 2 Remove th...
Страница 50: ...your earliest convenience with the same type and model Figure 3 18 Fan Housing Placement Changing a System Fan 1 Determine which fan is failing If possible use IPMI If not remove the chassis cover wh...
Страница 51: ...fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans 7 Put the fan housing b...
Страница 52: ...drive bays Make sure no wires or foreign objects obstruct airflow through the chassis Pull all excess cabling out of the airflow path or use shorter cables Installing the Air Shrouds The system requir...
Страница 53: ...20v or 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Replacing the Power Supply 1 Unplug...
Страница 54: ...pin fans The onboard fan speeds are controlled by Thermal Management through the BIOS Hardware Monitoring When using the Thermal Management setting please use all 3 pin fans or all 4 pin fans Fan Head...
Страница 55: ...y for use with a Supermicro chassis PCI Express 3 0 Slots There are two PCIe slots on the motherboard for expansion cards Several other PCIe slots are used for proprietary cards Slot 1 SXB3 is a stand...
Страница 56: ...witch toggles the UID LED indicator on or off This indicator can be used to identify the node for troubleshooting or service Network Ports The primary LAN ports are provided by means of the SIOM card...
Страница 57: ...ns Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the conten...
Страница 58: ...inition Pins 1 2 Enabled Pins 2 3 Disabled Management Engine ME Recovery Use jumper JPME1 to select ME Firmware Recovery mode which will limit resource allocation for essential system operation only i...
Страница 59: ...ED Link LED left LED Color Definition Amber Solid 1 Gb s Green Solid 100 Mb s IPMI LAN Link LED Activity LED BMC Heartbeat LED BMC_HB_LED1 is the BMC heartbeat LED When the LED is blinking green BMC i...
Страница 60: ...e at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB fla...
Страница 61: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...
Страница 62: ...preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flas...
Страница 63: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...
Страница 64: ...gent Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and informati...
Страница 65: ...ected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of settings...
Страница 66: ...Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in...
Страница 67: ...to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST mess...
Страница 68: ...ring the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA optical drive as a USB drive and USB CD DVD drives are not supported Disable this feature after the XHCI...
Страница 69: ...ocket Processor ID Processor Frequency Processor Max Ratio Processor Min Ratio Microcode Revision L1 Cache RAM L2 Cache RAM L3 Cache RAM Processor 0 Version Processor 1 Version Hyper Threading ALL Ava...
Страница 70: ...CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enable DCU Streamer Prefetcher Available when supported by the CPU Select Enabled to enable the DCU Data Cache Uni...
Страница 71: ...wer Manager is responsible for coordinating the P state and may initiate the transition on any Logical Processors Options available HW_ALL SW_ALL SW_ANY Default setting is HW_ALL Turbo Mode This featu...
Страница 72: ...6 Retention state No Limit and Auto CPU T State Control Software Controlled T States Enabling this feature allows the OS to choose a T State The options are Enable and Disable Chipset Configuration Wa...
Страница 73: ...Remote InvItoM and Remote WViLF Isoc Mode Select Enabled for Isochronous support to meet QoS Quality of Service requirements This feature is especially important for Virtualization Technology The opti...
Страница 74: ...s providing 100 re dundancy The options are Disable Mirror Mode 1LM and Mirror Mode 2LM UEFI ARM Mirror This options allows the system to imitate the behavior of the UEFI based Address Range Mirror wi...
Страница 75: ...and Enable Patrol Scrub Interval This feature allows you to decide how many hours the system should wait before the next complete patrol scrub is performed Use the keyboard to enter a value from 0 24...
Страница 76: ...128B or 256B will designate maximum packet size of 128 or 256 Options are Auto 128 and 256 Auto is enabled by default CPU2 Configuration IOU0 II0 PCIe Br1 This item configures the PCI E port Bifuracti...
Страница 77: ...pages Enabling this feature will increase performance The options are No and Yes Prioritize TPH Use this feature to enable Prioritize TPH support The options are Enable and Disable Relaxed Ordering Se...
Страница 78: ...her devices Select Enable for the Non Iscoh VT d engine to pass through DMA to enhance system performance The options are Enable and Disable Intel VMD Technology Intel VMD for Volume Management Device...
Страница 79: ...Config for PStack2 Intel VMD for Volume Management Device Select Enable to use the Intel Volume Management Device Technology for this stack The options are Disable and Enable If the item Intel VMD for...
Страница 80: ...ement Device above is set to Enable the following items will be dislayed VMD port 2A VMD port 2D Available when the device is detected by the system Select Enable to use the Intel Volume Management De...
Страница 81: ...the motherboard will not support USB 3 0 Options are Enabled and Disabled Default setting is Disabled Port 60 64 Emulation This feature allows legacy I O support for USB devices like mice and keyboard...
Страница 82: ...d periods of I O inactivity and will return the link to an active state when I O activity resumes The options are Disabled and Enabled If the item above Configure SATA as is set to RAID the following...
Страница 83: ...put the link in a low power mode during extended periods of I O inactivity and will return the link to an active state when I O activity resumes The options are Disabled and Enabled If the item above...
Страница 84: ...ct Enabled to allow a PCI device to generate a PERR SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled Maximum Read Request Select Auto for the system BIOS to automatica...
Страница 85: ...elect Enabled to enable PXE Preboot Execution Environment or UEFI Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled If Network Stack is set to Enable...
Страница 86: ...Port 2 are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Serial...
Страница 87: ...use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits per second Use this feature to set the transmission speed for a serial port used i...
Страница 88: ...sabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled Legacy OS Redirection Resolution Use this feature to select the number...
Страница 89: ...per second Flow Control Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer i...
Страница 90: ...s an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The options are Enabled and Disabled Trusted Computing Configura...
Страница 91: ...be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Every Reset data in the event log will be erased upon every system reboot The options are No Ye...
Страница 92: ...vents before MECI is incremented This is in minutes from 0 to 99 The default value is 60 Note After making changes on a setting be sure to reboot the system for the changes to take effect View SMBIOS...
Страница 93: ...Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Every Reset da...
Страница 94: ...before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass between duplicate log events before...
Страница 95: ...ontroller This item indicates the status of the IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup...
Страница 96: ...LAN Configuration Select Yes for the BIOS to implement all IP MAC address changes at the next system boot The options are No and Yes If the item above set to Yes the following item will become availa...
Страница 97: ...The options are Enabled and Disabled Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need to know the...
Страница 98: ...d Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup f...
Страница 99: ...are Yes and No Enroll EFI Image Select this item and press Enter to select an EFI Extensible Firmware Interface image for the system to operate in Secure Boot mode Save All Secure Boot Variables This...
Страница 100: ...ature allows the user to enter and configure a set of values to be used as Forbidden Signatures for the system This set of values also indicate the size the keys numbers and the key source of the Forb...
Страница 101: ...y boot order has failed The options are Disabled and Enabled Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on each ent...
Страница 102: ...Option Use this feature to select a boot device to delete from the boot priority list Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list UEFI Application Boot...
Страница 103: ...and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer...
Страница 104: ...e As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults...
Страница 105: ...corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No m...
Страница 106: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...
Страница 107: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 108: ...ken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...
Страница 109: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 110: ...tes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l inst...
Страница 111: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 112: ...abels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Wa...
Страница 113: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 114: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 115: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 116: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All c...
Страница 117: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 118: ...dvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques c...
Страница 119: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 120: ...ale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accord...
Страница 121: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 122: ...estornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient t...
Страница 123: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 124: ...r le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto u...
Страница 125: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 126: ...e controls three NVMe SAS drives and three SAS drives Two M 2 SSD cards PCI Expansion Slots per node Two PCIe 3 0 x8 slots One PCIe 3 0 x16 One SIOM card support must bundle with network card Motherbo...
Страница 127: ...4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Directive EU 2015...
Страница 128: ...ge The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...
Страница 129: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...
Страница 130: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed...
Страница 131: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...
Страница 132: ...nterrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power s...
Страница 133: ...urpose you can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2...
Страница 134: ...stem remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellanous tab then the Trou...
Страница 135: ...pid Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise I...
Страница 136: ...JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd par...
Страница 137: ...h to Advanced Chipset Configuration North Bridge IIO Configuration Intel VMD Technology Intel VMD for Volume Management on CPU2 5 Enable the VMD Figure F 2 BIOS VMD Settings 6 Press F4 to save the con...
Страница 138: ...ller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure F 4 12 Select specific disks for RAID with an X RAID0 Select at least two 2 24 disks RAID1 Select only two disks...
Страница 139: ...e device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215...