background image

USER'S MANUAL

Revision 1.0a

SUPERSERVER

®

6028TP-HC0R

6028TP-HC0TR

6028TP-HC0FR

Содержание SUPERSERVER 6028TP-HC0FR

Страница 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 6028TP HC0R 6028TP HC0TR 6028TP HC0FR...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...steps necessary to install the SuperServer 6028TP HC0R HC0TR HC0FR into a rack and check out the server configuration prior to powering up the system If your server was ordered without processor and...

Страница 4: ...edures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes...

Страница 5: ...v SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...

Страница 6: ...Ports 1 4 Cooling System 1 4 Air Shrouds 1 4 Mounting Rails 1 4 1 5 Contacting Supermicro 1 6 1 6 2U Twin2 System Notes 1 7 Nodes 1 7 System Power 1 7 SAS SATA Backplane 1 7 Chapter 2 Server Installa...

Страница 7: ...nstructions 4 4 Circuit Breaker 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply wit...

Страница 8: ...uds 6 4 6 5 Checking the Airflow 6 5 6 6 System Fans 6 5 Optional Fan Configurations 6 5 6 7 Removing and Installing the Backplane 6 8 Removing the Backplane 6 8 Installing the Backplane 6 10 6 8 Inst...

Страница 9: ...ns 7 4 7 4 Event Logs 7 32 7 5 IPMI 7 34 7 6 Security Settings 7 36 7 7 Boot Settings 7 37 7 8 Save Exit 7 39 Appendix A BIOS Error Beep Codes Appendix B System Specifications Appendix C Chinese Safet...

Страница 10: ...x Notes SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL...

Страница 11: ...s for rear CPU SNK P0047PSM Four 1U passive CPU heatsinks w narrow ILM SNK P0057PS Four mylar air shrouds MCP 310 21702 0B Four 80x80x38mm cooling fans FAN 0136L4 SATA SAS Backplane Four HD backplanes...

Страница 12: ...o 1024 GB of LRDIMM Load Reduced DIMM or 512 GB of RDIMM Registered DIMM DDR4 2133 1866 1600 MHz registered ECC memory See Chapter 5 for details Note Check the Supermicro website for the latest memory...

Страница 13: ...atures an integrated ASpeed 2400 BMC with an integrated VGA 2D graphics controller InfiniBand The 6028TP HC0FR server include a FDR fourteen data rate speed InfiniBand QSFP connector InfiniBand is a s...

Страница 14: ...t button are also included I O Ports The SC827HQ is an proprietary form factor chassis designed to be used in a 2U rackmount configuration The SC827HQ chassis provides a low profile add on card slot a...

Страница 15: ...RL FAN SPEED PCI E X1 G2 USB 2 0 PCH C612 6 0 Gb S LPC 1 0 SATA 5 4 RTL8211E VB CG 3 2 RJ45 Temp Sensor EMC1402 1 2 at diff SMBUS TPM HEADER USB 3 0 USB AST2400 BMC RMII NCSI VGA CONN BMC Boot Flash D...

Страница 16: ...icro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information suppo...

Страница 17: ...op when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a node in until you hear the click of the locking tab seating itself...

Страница 18: ...1 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...

Страница 19: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer 6028TP...

Страница 20: ...le rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component fro...

Страница 21: ...ible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable...

Страница 22: ...age includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the server chassis and an outer fixed rack rail th...

Страница 23: ...Rails Figure 2 2 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre at...

Страница 24: ...uter Rails to the Rack Figure 2 3 1 Secure the back end of the outer rail to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rai...

Страница 25: ...e outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked...

Страница 26: ...2 8 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...

Страница 27: ...he drive carriers to keep you constantly informed of the overall status of the system SC827HQ models include four front panels on the handles of the chassis which control each of the systems This chap...

Страница 28: ...he system This section explains what each LED indicates when illuminated and any corrective action you may need to take Overheat This LED is illuminated when an overheat condition occurs A solid red L...

Страница 29: ...this blue LED on the front of the drive carrier indicates drive activity A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LE...

Страница 30: ...SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL 3 4 Notes...

Страница 31: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 32: ...quipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encon...

Страница 33: ...letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard...

Страница 34: ...Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de...

Страница 35: ...alliert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorriente...

Страница 36: ...reift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing...

Страница 37: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 38: ...ent Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplaz...

Страница 39: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 40: ...the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden me...

Страница 41: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 42: ...nexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour...

Страница 43: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 44: ...onal electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacional...

Страница 45: ...re install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Warnung Di...

Страница 46: ...Hazardous moving parts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the ope...

Страница 47: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Страница 48: ...roducts designated by Supermicro only Power Cable and AC Adapter Warnung Nutzen Sie beim Installieren des Produkts ausschlie lich die von uns zur Verf gung gestellten Verbindungskabeln Stromkabeln und...

Страница 49: ...ros dispositivos el ctricos que los productos designados nicamente por Supermicro Attention Attention Lors de l installation du produit utilisez les cables de connection fournis ou d sign ou achetez d...

Страница 50: ...ffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een st...

Страница 51: ...ending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use...

Страница 52: ...ipheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back If you need to disconnect any...

Страница 53: ...O ports and the UID switch Figure 5 1 Rear I O Ports Rear I O Port Locations and Definitions 1 Dedicated IPMI LAN 2 Back Panel USB 3 0 Port 1 3 Back Panel USB 3 0 Port 0 4 Gigabit LAN 2 5 Gigabit LAN...

Страница 54: ...y a CPU separately use only an Intel certified multi directional heatsink Avoid placing direct pressure to the top of the processor package Install the processor into the CPU socket before installing...

Страница 55: ...edges will fit the socket OPEN1st IMPORTANT Caution You can only install the CPU into the socket in one direction Make sure that the CPU is properly inserted into the socket before closing the load pl...

Страница 56: ...Close and lock the Close 1st lever Push down and lock the lever labeled Open 1st OPEN1st OPEN1st Push down and lock the lever labeled Close 1st 9 Close and lock the Open 1st lever Engage the lip of th...

Страница 57: ...heatsink on top of the CPU so that the four mounting holes are aligned with those on the serverboard and the heatsink bracket underneath 3 Screw in two diagonal screws i e the 1 and the 2 screws until...

Страница 58: ...from the serverboard in the sequence as shown in the illustration below 2 Gently wriggle the heatsink to loosen it from the CPU Do not use excessive force when wriggling the heatsink 3 Once the heats...

Страница 59: ...pulating the DIMM slots Note It is highly recommended that you remove the power cord from the system before installing or changing memory modules Please refer to our web site for memory that has been...

Страница 60: ...P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 Any memory pairs in P1 P2 DIMM slots 2 CPUs 16 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIM MG1 P2 DIMMH1 P1 DIMMA2 P1 DI...

Страница 61: ...I Express x16 card to fit inside the chassis for each node Installing an Expansion Card 1 After powering down the system remove the PCI slot shield 2 Fully seat the card into the slot pushing down wit...

Страница 62: ...UID_LED1 BMC_HB_LED1 JPG1 JPB1 JVRM2 JVRM1 JWD1 JPL1 CPU2 PCI E 3 0 X16 CPU2 SLOT1 PCI E 3 0 X16 PCI E 3 0 X8 CPU2 SLOT2 UID SW BATTERY BIOS BMC VGA QSFP LAN1 LAN2 IB 10G 1G 3 0 USB0 1 IPMI_LAN SATA D...

Страница 63: ...odule Port 80 LAN1 2 Gb Ethernet Ports 1 2 IPMI LAN Dedicated IPMI LAN Port QSFP Quad channel Small Form factor Pluggable QSFP Transceiver Connector used as Connect X3 InfiniBand Port X10DRT PIBF S SA...

Страница 64: ...ports accept RJ45 type cables Note Refer to the LED Indicator Section for LAN LED information Main Power Main power to the serverboard is supplied through the system backplane BPN SAS3 827HQ which re...

Страница 65: ...CRT display IPMB I2 C SMB A System Management Bus header for the IPMI slot is located at JIPMB1 Connect an appropriate cable here to use the IPMB I2 C connection on your system Unit Identifier Switch...

Страница 66: ...an appropriate cable here to provide power for your SATA DOM devices DOM PWR Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground SATA DOM Power Conection A SATA DOM with power pin is located at S SA...

Страница 67: ...able Disable JPL1 enables or disables the LAN1 2 Ethernet ports on the serverboard See the table on the right for jumper settings The default setting is Enabled LAN Enable Jumper Settings Jumper Setti...

Страница 68: ...Pins 1 2 Reset Pins 2 3 NMI Open Disabled VGA Enable Jumper JPG1 allows the user to enable the onboard VGA connectors The default setting is pins 1 2 to enable the connection See the table on the righ...

Страница 69: ...ions associated with the connection speed LED LAN Port LED Connection Speed Indicator LED Color Definition Off 10 Mbps Green 100 Mbps Amber 1 Gbps IPMI LAN Link LED Left Activity LED Right Color State...

Страница 70: ...SATA Connected Off No connection HDD SATA LED LE3 An HDD SATA LED Indicator is located at LE3 on the serverboard This LED indicates the status of hard drive activities or SATA activities supported by...

Страница 71: ...ions S SATA 0 2 CPU2_PCI Express 3 0 x16 Slot SXB1 A CPU2_PCI Express 3 0 x16 slot and S SATA 0 2 connections are located on the serverboard I SATA 0 5 CPU1_PCI Express 3 0 x8 Slot SXB2 A CPU1_PCI Exp...

Страница 72: ...es directory and locate the ISO file for your serverboard Download this file to create a CD DVD of the drivers and utilities it contains You may also use a utility to extract the ISO file if preferred...

Страница 73: ...nt versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for m...

Страница 74: ...battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulations set up b...

Страница 75: ...m very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded...

Страница 76: ...located on the front of the chassis The LEDs inform you of system status See Chapter 3 for details on the LEDs and the control panel buttons SAS orSATA Drives 12 Control Panel Control Panel Control Pa...

Страница 77: ...over onto the chassis as shown above 2 Lift the top cover up and off the chassis 3 Peel off the protective film covering the top cover and the top of the chassis 4 Check that all ventilation openings...

Страница 78: ...rouds one in each serverboard drawer p n MCP 310 21702 0B See the illustration below Installing an Air Shroud 1 Confirm that all four fans are in place and are working properly 2 Place the first air s...

Страница 79: ...ering the chassis internal temperature The SC827HQ system fans are hot swappable There is no need to power down the system when replacing fans and new tools are required for installation Optional Fan...

Страница 80: ...an housing up and out of the chassis 4 Push the fan up from the bottom and out of the top of the housing 5 Place the replacement fan into the vacant space in the housing while making sure the arrows o...

Страница 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...

Страница 82: ...the Backplane Removing the Backplane from the Chassis 1 Power down and unplug the system from any power source 2 Remove the chassis cover 3 Disconnect the cabling to the backplane 4 Remove all of the...

Страница 83: ...side screw from the side of the chassis Figure 6 7 8 Gently ease the backplane up and out of the chassis Figure 6 8 Figure 6 7 Loosening the Spring Bar Screws in the Floor of the Chassis Figure 6 8 Re...

Страница 84: ...s provided 3 Slide the backplane into the chassis at a slight angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the chassis This will aid in the ali...

Страница 85: ...rounded side up Depending upon the configuration of the serverboard being used it is also possible that some of the optional standoffs which are pre installed in the chassis may need to be removed In...

Страница 86: ...e serverboard backplane chassis front panel and power supply as needed Also fans may be temporarily removed to allow access to the backplane ports 9 Replace the add on card bracket and secure the brac...

Страница 87: ...erverboard drawer by removing the screws securing it to the drawer Set the screws aside for later use 4 Remove the five screws securing the adapter card to the drawer and set them aside for later use...

Страница 88: ...clip in the rear of the chassis 3 Slide the temporary PCI slot shield toward the slot clip and remove the temporary shield from the chassis 4 Connect the add on card to the riser card 5 Secure the ri...

Страница 89: ...anuals The SC827HQ chassis contains four individual serverboards in separate node drawers Figure 6 13 Each serverboard node controls a set of three hard drives Note that if a serverboard node drawer i...

Страница 90: ...USER S MANUAL Removing Hard Drive Trays from the Chassis Figure 6 14 1 Press the release button on the drive tray This extends the drive bay handle 2 Use the handle to pull the drive out of the chassi...

Страница 91: ...r the drive bays Figure 6 15 Chassis Drive Tray Figure 6 16 Removing Dummy Drive from Tray Drive Tray Dummy Drive 1 1 1 1 Caution Except for short periods of time while swapping hard drives do not ope...

Страница 92: ...d drive by tightening all six 6 screws 3 Use the open handle to replace the drive tray into the chassis Make sure the close the drive tray handle Figure 6 17 Installing the Hard Drive Drive Tray SATA...

Страница 93: ...r supply unit needs to be replaced one power supply can be removed without powering down the system Replacement units can be ordered directly from Supermicro See the contact information in the Preface...

Страница 94: ...6 20 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Release Tab Figure 6 18 Changing the Power Supply...

Страница 95: ...be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left...

Страница 96: ...Warning Do not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirec...

Страница 97: ...YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10DRT P Series BIOS Version This item displays the versio...

Страница 98: ...uiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of t...

Страница 99: ...allow the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Sele...

Страница 100: ...sabled and Enabled Execute Disable Bit Available if supported by the OS the CPU Select Enable for Execute Disable Bit Technology support which will allow the processor to designate areas in the system...

Страница 101: ...d up data accessing and processing to enhance CPU performance The options are Disable and Enable DCU IP Prefetcher If set to Enable the IP prefetcher in the DCU Data Cache Unit will prefetch IP addres...

Страница 102: ...y security and availability in networking and data sharing The options are Enable and Disable Advanced Power Management Configuration Advanced Power Management Configuration Power Technology Select En...

Страница 103: ...C3 Report Select Enable to allow the BIOS to report the CPU C3 State ACPI C2 to the operating system During the CPU C3 State the CPU clock generator is turned off The options are Enable and Disable C...

Страница 104: ...port Bifuraction setting for a PCI E port specified by the user The options are x4x4 x8 and Auto IOU0 II0 PCIe Port 2 This item configures the PCI E port Bifuraction setting for a PCI E port specifie...

Страница 105: ...x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto PORT 3A Link Speed This item configures the link speed of a PCI E port specified by the user The options are Gen 1 Generation 1 2 5 GT s Gen 2 Generation 2 5 G...

Страница 106: ...Disable Interrupt Remapping Select Enable for Interrupt Remapping support to enhance system performance The options are Enable and Disable Coherency Support Non Isoch Select Enable for the Non Iscoh V...

Страница 107: ...noop Available when the OS and the CPU support this feature Select Enable for Early Snoop support to enhance system performance The options are Enable Disable and Auto Isoc Mode Select Enable for Isoc...

Страница 108: ...o sockets The options are Enable and Disable Channel Interleaving Use this item to set DIMM channel interleaving mood The options are Auto 1 Way Interleave 2 Way Interleave 3 Way Interleave and 4 Way...

Страница 109: ...no delay caused by internal processing By using this method roughly 64 GB of memory behind the IO hub will be scrubbed every day The options are Enable and Disable Patrol Scrub Interval This feature a...

Страница 110: ...This item is for operating systems that do not support Enhanced Host Controller Interface EHCI hand off When this item is enabled EHCI ownership change will be claimed by the EHCI driver The settings...

Страница 111: ...ed to enable XHCI Extensible Host Controller Interface support on a pre boot drive specified by the user The options are Enabled and Disabled XHCI Idle L1 Select Enabled for XHCI Extensible Host Contr...

Страница 112: ...s item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time...

Страница 113: ...e Configure SATA as is set to RAID the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SA...

Страница 114: ...ays the following items sSATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH sSATA controller The options are Enabled and Disabled Configure sSATA as S...

Страница 115: ...Disk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to IDE the following items will display sSATA Port 0 Port 3 This item indicates that an sSA...

Страница 116: ...gging Set this item to Enabled for hot plugging support which will allow the user to replace an sSATA drive without shutting down the system The options are Enabled and Disabled sSATA Port 0 Port 3 Sp...

Страница 117: ...card pal ette and mimic it for proper color display The options are Disabled and Enabled PCI AER Advanced Error Reporting Support Select Enabled to support Advanced Error Reporting for onboard PCI dev...

Страница 118: ...this item to select the high I O memory size according to memory address mapping for the PCH chip The options are 256G 128G 512G and 1024G PCI PCIX PCIe Slot 1 OPROM PCI PCIX PCIe Slot 2 OPROM PCI PC...

Страница 119: ...Serial Port 1 or Serial Port 2 Select Auto for the BIOS to automatically assign the base I O and IRQ address to a serial port specified The options for Serial Port 1 are Auto IO 3F8h IRQ 4 IO 3F8h IRQ...

Страница 120: ...ata transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parit...

Страница 121: ...x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT...

Страница 122: ...eature to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent along with regular data bits to detect data transmission errors Selec...

Страница 123: ...emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redirection after BIOS POS...

Страница 124: ...more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in b...

Страница 125: ...motherboard ACPI Settings WHEA Support Select Enabled to support the Windows Hardware Error Architecture WHEA plat form and provide a common infrastructure for the system to handle hardware errors wit...

Страница 126: ...support Runtime Error Logging The options are Enable and Dis able If this item is set to Enable the following item will be available for configuration Memory Corrected Error Enabling Available when th...

Страница 127: ...led to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The defa...

Страница 128: ...e IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disa...

Страница 129: ...ct the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS wil...

Страница 130: ...prompt for a password at bootup and upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required b...

Страница 131: ...starts to boot The default setting is 1 Boot Mode Select Use this item to select the type of device to be used for system boot The options are Legacy UEFI and Dual Fixed Boot Order Priorities This op...

Страница 132: ...2 Dual Boot Order 13 Dual Boot Order 14 Dual Boot Order 15 Delete Boot Option Use this item to select a boot device to delete from the boot priority list Delete Boot Option Select the target boot devi...

Страница 133: ...s and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters to take eff...

Страница 134: ...s Select this item and press Enter to save the current BIOS settings as user s default settings for future use Restore User Defaults Select this item and press Enter to retrieve user defined settings...

Страница 135: ...th your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to t...

Страница 136: ...A 2 SUPERSERVER 6028TP HC0R HC0TR HC0FR USER S MANUAL Notes...

Страница 137: ...1024 GB of LRDIMM Load Reduced DIMM or 512 GB of RDIMM Registered DIMM DDR4 2133 1866 1600 MHz registered ECC memory Note refer to Section 5 6 for details on installation Note check the Supermicro we...

Страница 138: ...C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN...

Страница 139: ...B 3 Appendix B System Specifications Notes...

Страница 140: ...e to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell...

Страница 141: ...C 1 Appendix C Chinese Safety Warnings Appendix C Chinese Safety Warnings...

Страница 142: ...on of the Presence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indi...