5-2
S
UPERSERVER 6013P-T User’s Manual
IMPORTANT:
Always connect the power cord last and always remove it
before adding, removing or changing any hardware components. Make
sure that you install the processor into the CPU socket
before
you install
the heatsink. The X5DPR-TG2+ can support either one or two Xeon 604 or
603-pin processors of up to 3.06 GHz. If installing one processor only,
install it into CPU socket #1.
!
5-2
PGA Processor and Heatsink Installation
When handling the processor package, avoid placing direct
pressure on the label area of the fan. Also, do not place the
serverboard on a conductive surface, which can damage the
BIOS battery and prevent the system from booting up.
1. Lift the lever on the CPU socket.
Lift the lever completely or you will
d a m a g e t h e C P U s o c k e t w h e n
power is applied. (Install a proces-
sor into CPU #1 socket first.)
2. Install the CPU in the socket.
Make sure that pin 1 of the CPU is
seated on pin 1 of the socket (both
corners are marked with a triangle).
When using only one CPU, install it
into CPU socket #1 (CPU socket #2
is automatically disabled if only one
CPU is used).
3. Press the lever down until you
hear it *click* into the locked posi-
tion. See Figure 5-1 for pictures of
the 604-pin CPU socket before and
after the processor is installed.
Socket lever
Pin 1
Socket lever in
locked position
Содержание SuperServer 6013P-T
Страница 1: ...SUPERSERVER 6013P T USER SMANUAL 1 0a SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6013P T User s Manual x Notes...
Страница 18: ...SUPERSERVER 6013P T Manual 1 8 Notes...
Страница 28: ...2 10 SUPERSERVER 6013P T Manual Notes...
Страница 32: ...3 4 SUPERSERVER 6013P T User s Manual Notes...
Страница 40: ...5 4 SUPERSERVER 6013P T User s Manual Figure 5 2 Heatsink Installation...
Страница 68: ...6 10 SUPERSERVER 6013P T Manual Figure 6 6 Removing Replacing the Power Supply with optional front bezel shown...
Страница 92: ...7 24 SUPERSERVER 6013P T Manual Notes...
Страница 98: ...A 6 SUPERSERVER 6013P T Manual Notes...
Страница 104: ...B 6 SUPERSERVER 6013P T Manual Notes...
Страница 120: ...C 16 SUPERSERVER 6013P T Manual...
Страница 127: ...Appendix C Software Installation C 23 Notes...
Страница 131: ...D 4 SUPERSERVER 6013P T Manual Notes...