background image

Appendix D: System Specifications

119

Appendix C  

 

System Specifications

Processors

Single Intel Xeon E-2200/2100, 9th/8th Generation Core i3, Pentium, or Celeron in a H4 - LGA 1151 socket 

with a thermal 

design power (TDP) of up to 95W and six cores

Note: Refer to the motherboard specifications pages on our website for updates to supported processors.

Chipset

Intel C242

BIOS

256Mb AMI BIOS

®

 SPI Flash BIOS

Memory

Up to 128 GB of unbuffered (UDIMM) DDR4 (288-pin) ECC memory with speeds of up to 2666MHz in four memory slots

Storage Drives

Internal SATA drives: up to two 3.5" or up to three 2.5"
One M.2 slot for

 

PCI-E

 3.0 x4 (Supports M-Key 2280 / 22110 and Intel Optane Memory)

PCI Expansion Slots

One PCI-Express 3.0 x16

Input/Output

Network: Four 1GbE BASE-T ports (Intel i210) 
IPMI: Dedicated LAN port
USB: Two USB 2.0 ports, two USB 3.1 Gen 1 ports on the rear I/O panel 
Video : One VGA port
Serial: One serial port header (COM1) (internal)

Motherboard

X11SCL-LN4F; 9.6" (W) x 9.6" (L) (243.8mm x 243.8mm)

Chassis

SC512F-350B1; 1U rackmount; (WxHxD) 17.2 x 1.7 x 14.5 in. (437 x 43 x 369 mm)

System Cooling

Two 4-cm counter-rotating fans, CPU heatsink, air shroud to direct air flow

Power Supply

Model: PWS-350-1H, 350 W module, 80Plus Platinum level
AC Input 
   100-127 Vac, 50-60 Hz
   200-240 Vac, 50-60 Hz
+12 V: 29 A
+12 V standby: Max: 3 A, Min: 0 A
+ 5 V: 15 A
+3.3 V: 12 A

Operating Environment

Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)

Содержание SuperServer 5019C-M4L

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 5019C M4L...

Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful int...

Страница 3: ...nd the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp Product safety info http www supermi...

Страница 4: ...ng Merchandise for Service 16 Chapter 2 Server Installation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Consideratio...

Страница 5: ...VD Drive 36 PCI Expansion Cards 37 System Fans 38 Installing the Air Shroud 40 Checking the Server Air Flow 41 Overheating 41 Power Supply 42 Chapter 4 Motherboard Connections 4 1 Power Connections 43...

Страница 6: ...p Utility 59 6 2 Main Setup 59 6 3 Advanced Setup Configurations 61 6 4 Event Logs 83 6 5 IPMI 85 6 6 Security 88 6 7 Boot 92 6 8 Save Exit 96 Appendix A BIOS Error Codes Appendix B Standardized Warni...

Страница 7: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 8: ...1H 1 Fans FAN 0087L4 2 Air Shroud MCP 310 50504 0B 1 Heatsink SNK P0049P 1 Riser Card RSC RR1U E16 1 1 2 Unpacking the System Inspect the box in which the system was shipped and note if it was damaged...

Страница 9: ...666MHz in four memory slots Chipset Intel C242 Expansion Slots One PCI Express 3 0 x16 Storage Drives Internal SATA drives up to two 3 5 or up to three 2 5 One M 2 slot for PCI Express 3 0 x4 Supports...

Страница 10: ...utton Reboots the system 7 Power Button Applies or removes power from the power supply to the server standby power is maintained Information LED Status Description Continuously on and red An overheat...

Страница 11: ...m Feature Description 1 DVD Optional DVD drive 2 Control Panel Front control panel with LEDs and buttons see preceding page Figure 1 2 Chassis Front View Front Features The illustration below shows th...

Страница 12: ...tures Description 1 Power Supply 350W Platinum Level Power Supply p n PWS 350 1H 2 I O Backpanel Rear I O ports see below and Section 4 3 3 Expansion Card Slot Slot for one expansion card requires pre...

Страница 13: ..._HB_LED LED4 JUIDB1 JWD1 JPME2 JPG1 JBAT1 SP1 USB2 3 JTPM1 I SGPIO1 I SGPIO2 JBT1 I SATA3 I SATA2 I SATA1 I SATA0 I SATA5 I SATA4 JL1 FANB FANA JSD2 JSD1 JSTBY1 USB8 3 0 JLED1 JF1 FAN3 PWR_LED ASpeed...

Страница 14: ...board Buzzer JF1 Front Control Panel Header JL1 Chassis Intrusion Header JLED1 Onboard Power LED Header JLD1 LAN3 LAN4 Activity LED Connector JLD2 LAN5 LAN8 Activity LED Connector not applicable in th...

Страница 15: ...eSPI CPU_PE3 INTEL LGA1151 SVID DDR4 CHA DIMMA2 Blue DIMMA1 DDR4 CHB 65W 71W 80W 95W PCIe x16 SLOT DIMMB1 DIMMB2 Blue RJ45 GLAN1 I210 AT RJ45 GLAN2 I210 AT REAR USB USB Header MUX VGA COM1 RMII NCSI...

Страница 16: ...hould be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is...

Страница 17: ...on Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enou...

Страница 18: ...n not servicing always keep the front door of the rack and all covers panels on the servers closed to maintain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in...

Страница 19: ...ing guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially filled rack load the r...

Страница 20: ...ludes two assemblies that consists of two sections an inner rail that secures to the chassis and an outer rail that secures to the rack Note that the rails are left right side specific Installing the...

Страница 21: ...Attach the other outer rail assembly to the other side of the rack making sure that both are at the exact same height and with the rail guides facing inward Installing the Server into the Rack After t...

Страница 22: ...rServer 5019C M4L User s Manual 22 Note Figures are for illustrative purposes only Always install servers to the bottom of a rack first Figure 2 3 Installing the Server into a Rack with Optional Rail...

Страница 23: ...er into a Telco Rack 2 5 Installing the Server into a Telco Rack If you are installing the 5019C M4L into a two post Telco rack follow the directions on the previous pages The only difference in the i...

Страница 24: ...follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non...

Страница 25: ...cover to the chassis 2 Slide the cover toward the rear of the chassis 3 Lift the cover from the chassis Check that all ventilation openings on the top cover and the top of the chassis are clear and un...

Страница 26: ...cing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or CPU socket which may require manufacturer repairs Refer to...

Страница 27: ...the CPU by the edges with your thumb and index finger align the triangle on the CPU with the triangle on the socket The CPU keys the semi circle cutouts may also be aligned against the socket keys as...

Страница 28: ...operly installed Load lever locked into place Note You can only install the CPU in one direction Make sure it is properly inserted into the socket before closing the load plate If it doesn t close pro...

Страница 29: ...ce the heatsink on top of the CPU so that the four mounting holes are aligned with those on the heatsink retention bracket 2 Screw in two diagonal screws i e the 1 and the 2 screws until they are just...

Страница 30: ...the heatsink back and forth to loosen it from the CPU Do not use excessive force when dislodging the heatsink 3 Once the heatsink is loose remove it from the CPU 4 Clean the surface of the CPU and the...

Страница 31: ...MM Capacity GB Speed MT s Voltage V Slot Per Channel SPC and DIMM Per Channel DPC 2 Slots Per Channel DRAM Density 1DPC 2DPC 4GB 8GB 1 2V 1 2V Unbuffered DDR4 ECC SR 16GB 4x 4GB DIMMs 32GB 4x 8GB DIMM...

Страница 32: ...1 SP1 USB2 3 JTPM1 I SGPIO1 I SGPIO2 JBT1 I SATA3 I SATA2 I SATA1 I SATA0 I SATA5 I SATA4 JL1 FANB FANA JSD2 JSD1 JSTBY1 USB8 3 0 JLED1 JF1 FAN3 PWR_LED ASpeed AST2500 M 2 P_1 M 2 H_2 JD1 USB6 7 3 0 C...

Страница 33: ...ock it Press both edges straight down into the memory slot Notches Release Tabs 2 Align the key of the DIMM with the receptive point on the memory slot and with your thumbs on both ends of the module...

Страница 34: ...ing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the hol...

Страница 35: ...prise level drives are recommended for use in Supermicro servers For information on recommended HDDs visit the Supermicro website product pages at https www supermicro com products nfo Installing Stor...

Страница 36: ...supported Installing a DVD Drive 1 Remove power as described in Section 3 1 and remove the chassis cover 2 Secure the DVD drive with two screws one through the side of the chassis and one internal 3...

Страница 37: ...Note When installing with 2 5 storage drives install the drives first 1 Remove power as described in section 3 1 and remove the chassis cover 2 Remove the PCI slot shield on the chassis by releasing...

Страница 38: ...our earliest convenience with the same type and model the system can continue to run with a failed fan Note The chassis top cover must be installed for proper airflow Replacing System Fans 1 Determine...

Страница 39: ...39 Chapter 3 Maintenance and Component Installation 3 9 Installing Fans...

Страница 40: ...ximize fan efficiency It does not require screws to install Position the air shroud in the chassis as illustrated below in red outline The air shroud fits over the fans and over the CPU If necessary m...

Страница 41: ...f the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating There are several possible responses if the system ove...

Страница 42: ...ternal components 3 Remove the two screws on the back of the power supply and a third from the front of the power supply which secures it to the bottom of the chassis Lift the unit straight out of the...

Страница 43: ...cation An 8 pin JPW2 processor power connector must also be connected to your power supply ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 NC 2 3 3V 15 GND 3...

Страница 44: ...k 2 12V Red 3 Tachometer 4 PWM Control TPM Port 80 Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from Supermicro TPM Port 80 is a security device...

Страница 45: ...Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 GND COM Header There is one COM header COM1 on the motherboard that can provide serial communication support COM Header Pin Definitions Pi...

Страница 46: ...h the enclosure management chip on the back panel SGPIO Header Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 GND 4 DATA Out 5 Load 6 GND 7 Clock 8 NC NC No Connection I SGPIO 1 2 I SGPIO1...

Страница 47: ...are yellow SATADOM connectors with power pins built in and do not require separate external power cables These connectors are backwards compatible with non Supermicro SATADOMS that require an external...

Страница 48: ...rked on the motherboard The other end connects to the control panel PCB board Power Button Pin Definitions JF1 Pins Definition 1 Signal 2 Ground Power Button The Power Button connection is located on...

Страница 49: ...Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pins Definition 13 3 3V Stdby 14 HDD Active Overheat OH Fan Fail LED Connect an LED cable to pins 7 and 8 of the Front Control...

Страница 50: ...fer to the table below for pin definitions Power LED Pin Definitions JF1 Pins Definition 15 3 3V 16 PWR LED NMI Button The non maskable interrupt NMI button header is located on pins 19 and 20 of JF1...

Страница 51: ...panel Unit Identifier Switch UID LED Indicator A Unit Identifier UID Switch UID SW and a rear LED Indicator UID LED are located on the I O back panel When the user presses the UID switch the UID LED...

Страница 52: ...moved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which also clears any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clear...

Страница 53: ...ion Pins 1 2 Normal Pins 2 3 Manufacturing Mode Watchdog Timer Watchdog JWD1 is a system monitor that can reboot the system when a software application hangs Close pins 1 2 to reset the system if an a...

Страница 54: ...D indicator LED4 is located near the UID switch on the I O back panel If activated this LED provides easy identification of a unit that needs service Onboard Power LED The Onboard Power LED is located...

Страница 55: ...lease use a method to slipstream the drivers 3 Select the partition on the drive in which to install Windows 4 Browse the USB folder for the proper driver files 5 Choose the RAID driver indicated in t...

Страница 56: ...ld appear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities...

Страница 57: ...Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can r...

Страница 58: ...telligent Platform Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and info...

Страница 59: ...lected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of setting...

Страница 60: ...s the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M...

Страница 61: ...ture to reduce the time the computer takes to boot up The computer will boot with a minimal set of required devices This feature does not have an effect on BBS boot options in the Boot tab The options...

Страница 62: ...utage Select Stay Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last State to allow the system to resume its...

Страница 63: ...are prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance The options are Disabled and Enabled Adjacent Cache Line Prefetch Availabl...

Страница 64: ...SpeedStep tm Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core frequency to reduce power consumption and heat dissipation The options are Disabled and Ena...

Страница 65: ...Demotion This feature allows the user to enable or disable the un demotion of C States The options are Disabled C1 C3 and C1 and C3 Package C State Demotion Use this feature to enable or disable the P...

Страница 66: ...LUD value which specifies the Top of Low Usable DRAM memory space to be used by internal graphic devices GTT Stolen Memory and TSEG respectively if these devices are enabled The options are Dynamic an...

Страница 67: ...abled Enabled and Auto Max Link Speed Use this feature to configure the link speed of a PCI E port specified by the user The options are Auto Gen1 Gen2 and Gen3 Power Limit Value Use this feature to s...

Страница 68: ...greater reliability security and availability in networking and data sharing The options are Disabled and Enabled GNA Device B0 D8 F0 This feature enables the SA GNA device The options are Enabled an...

Страница 69: ...n The following Super IO information will display Super IO Chip AST2500 Serial Port 1 Configuration This submenu allows the user to configure the settings of Serial Port 1 Serial Port 1 Select Enabled...

Страница 70: ...The options are Disabled and Enabled If the feature above is set to Enabled the following settings will become available for configuration COM1 Console Redirection Settings Use this feature to specif...

Страница 71: ...his feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal...

Страница 72: ...support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100 VT UTF8 and ANSI SOL Bits...

Страница 73: ...SOL Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled SOL Legacy OS Redirection Resolution Use this feature to select the number of rows an...

Страница 74: ...Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user EMS Out of Band Mgmt Port T...

Страница 75: ...will become available for configuration SATA Mode Selection Use this feature to select the mode for the installed SATA drives The options are AHCI and RAID SATA Frozen Use this feature to enable the H...

Страница 76: ...The following firmware information will display Operational Firmware Version Backup Firmware Version Recovery Firmware Version ME Firmware Features ME Firmware Status 1 ME Firmware Status 2 Current St...

Страница 77: ...Available when USB Functions are not Disabled Select Enabled to support legacy USB devices Select Auto to disable legacy support if USB devices are not present Select Disabled to have USB devices avai...

Страница 78: ...n ROM Use this feature to select the onboard video firmware type to be loaded The options are Legacy and EFI NVMe Firmware Source Use this feature to select the NVMe firmware to support booting The op...

Страница 79: ...the feature above is set to Enabled the following settings will become available for configuration Ipv4 PXE Support Select Enabled to enable IPv4 PXE boot support The options are Disabled and Enabled...

Страница 80: ...is feature to disable or enable the SHA 1 Platform Configuration Register PCR bank for the installed TPM device The options are Disabled and Enabled SHA256 PCR Bank Use this feature to disable or enab...

Страница 81: ...The options are TPM 1 2 TPM 2 0 and Auto SMCI BIOS Based TPM Provision Support Use feature to enable the Supermicro TPM Provision support The options are Disabled and Enabled TXT Support Intel Trusted...

Страница 82: ...features Add an Attempt Delete Attempts Change Attempt Order TLS Authentication Configuration This submenu allows the user to configure Transport Layer Security TLS settings Server CA Configuration En...

Страница 83: ...ng Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next reset data in the event log will be erased upon next system reboot Select Yes Every reset...

Страница 84: ...counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines the number of minutes that must pass between duplicate log events before MECI is...

Страница 85: ...mware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Er...

Страница 86: ...PMI LAN setting The default setting is Failover IPMI Network Link Status This feature displays the IPMI Network Link status The default setting is Shared LAN Configuration Address Source This feature...

Страница 87: ...e displays the IPV6 Address status The default setting is Disabled IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled If the feature above is set to Enabled the...

Страница 88: ...check for a password at bootup or upon entering the BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator password...

Страница 89: ...ey databases and force the system to Setup Mode The options are Yes and No Export Secure Boot variables Use this feature to copy the NVRAM contents of the secure boot variables to a file Enroll EFI Im...

Страница 90: ...abase from the manufacturer s defaults to the existing DB Select No to load the DB from a file The options are Yes and No Forbidden Signatures Update Select Yes to load the DBX from the manufacturer s...

Страница 91: ...FI SERT SHA256 bin 2 EFI Time Based Authenticated Variable When prompted select Yes to load Factory Defaults or No to load from a file Update Select Yes to load the DBR from the manufacturer s default...

Страница 92: ...ult setting is 1 Boot Mode Select Use this feature to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual Fixed Boot Order Priorities This feature prio...

Страница 93: ...ion 17 Delete Boot Option This feature allows the user to select an EFI boot option to delete from the boot order Delete Boot Option Use this feature to remove an EFI boot option from the boot priorit...

Страница 94: ...r system Add Driver Option Use this feature to specify the name for the new driver option Path for Boot Option Use this feature to enter the path for the new driver option in the format fsx path filen...

Страница 95: ...5 UEFI Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devices Boot Option 1 Hard Disk Drive BBS Priorities This feature sets the system boot order of detected devic...

Страница 96: ...ve Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you have completed t...

Страница 97: ...Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from...

Страница 98: ...ir corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error N...

Страница 99: ...assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...

Страница 100: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 101: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Страница 102: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 103: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 104: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 105: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 106: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 107: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 108: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 109: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 110: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 111: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 112: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 113: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 114: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 115: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 116: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 117: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...

Страница 118: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 119: ...ansion Slots One PCI Express 3 0 x16 Input Output Network Four 1GbE BASE T ports Intel i210 IPMI Dedicated LAN port USB Two USB 2 0 ports two USB 3 1 Gen 1 ports on the rear I O panel Video One VGA po...

Страница 120: ...11 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Perchlor...

Страница 121: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...

Страница 122: ...different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website...

Страница 123: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...

Страница 124: ...t to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built i...

Страница 125: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...

Отзывы: