background image

 http://www.supermicro.com

MNL-1368-QRG

Board Layout

SuperServer 5017P-TLN4F/TF Quick Reference Guide

Power Button

Reset Button

Power LED

Device Activity LED

LAN1 LED & LAN2 LED

Information LED

Description

No.

Rear View

Beep Codes

Front view & Interface

MEMORY

Caution

1

2

3

4

5

6

1

2

3

4

5

6

          SAFETY INFORMATION

IMPORTANT: See installation instructions and safety warning 

before  connecting system to power supply.

http://www.supermicro.com/about/policies/safety_information.cfm

          WARNING:

 

To reduce risk of electric shock/damage to equipment, 

disconnect power from server by disconnecting all power 

cords from electrical outlets.

If any CPU socket empty, install protective plastic CPU cap

          CAUTION:

 

Always be sure all power supplies for this system have

the same power output. If mixed power supplies are 

installed, the system will not operate.

For more information go to : 

http://www.supermicro.com/support

!

!

!

Description

No.

PCI-E x16 Gen 3 Slot

CPU

DIMMA1

DIMMB1

I-SATA5, I-SATA4, I-SATA3, I-SATA2 (Black connector: SATA2)

JSD1 = DOM (Disk on Module) Power Connector

I-SATA0, I-SATA1 (White connector: SATA3)

JF1 = Front panel control header

JBT1 = CMOS Clear

1

2

3

4

5

6

7

8

9

1

Description

No.

1

10

2

5

7

6

8

9

1

JWD1

UID

VGA

JWP1:WRITE PROTECT

PWR I2C

U6

0

I-SATA0

I-SATA1

JIP

MB1

T-SGPIO2

T-SGPIO1

JSD1

I-SATA5

I-SATA2

I-SATA4

I-SATA3

J1

F6

JCOM2

J20USB

1

SP1

LED2

LED1

LED3

U21

U7

U10

U22

U6

JDIMM1

JDIMM2

FA

N2

FA

N3

FA

N1

FA

N4

U26

JPW1

JPI2C1

JPK1

U3

JT

PM

1

JLAN1

JLAN2

MH7

MH6

MH2

MH4

JD1

JF1

JP1

JPUSB1

JPB1

JWP1

JL

1
JOH1

MH4

U57

X9SPV

-F

JTPM1:TPM/PORT80

DOM POWER

P1-DIMMB1

USB8/9

IP

MI

JSD1:SATA

COM2

USB6/7

LAN2/4

LAN1/3

P1-DIMMA1

COM1

USB4/5

KB/MOUSE

CPU1

JVGA1

JCOM1

J3

2

4 3

9

5

7

6

Informational LED

Status

Description

Blinking red (1Hz)

Fan failure, check for an inoperative fan.

Solid blue

Local UID has been activated. 

Use this function to locate 

Continuously 

on and red

An overheat condition has occured. 

(This may be caused by cable congestion.) 

Blinking red 

(0.25Hz)

Power failure, check for a non-operational 

power supply.

Blinking blue 

(300 m/s)

Remote UID is on. Use this function to identify 

the server from a remote location. 

BIOS Beep Codes

Video configuration error

Memory

No  memory  detected 

Error Message

Beep Code/LED

Description

1 long  + two short beeps

Video

1 repetitive long beep 

1 continuouse beep

w/Overheat LED

Overheat

System overheat detected

1 continuouse beep 

w/Fan Fail LED blinking

Fan

Fan failure detected

8 short beeps

Display

Display memory

read/write error

ÌMNL-1368-QRG4Î

8

4 3

Expansion Slot

VGA Port

Gb LAN 3/4 (5017P-TLN4F only)

Gb LAN 1/2 

USB Port 8/9

USB Port 4/5

COM Port 1

PS/2 Keyboard/Mouse

Dedicated IPMI LAN Port

Power Supply

1

2

3

4

5

6

7

8

9

10

Insert the SO DIMM module 

straight down. 

To Remove:

 

Use your thumbs to gently 

push the side clips near both 

ends away from the module. 

This should release it from 

the slot. Pull the SO DIMM 

module upwards.

The SO DIMM Socket

Position the SO DIMM 

module's bottom key so it 

aligns with the receptive 

point on the slot.  Take 

note of the module's side 

notches and the locking 

clips on the socket.

Press down until the module 

locks into place. The side 

clips will automatically secure 

the SO DIMM module, locking 

it into place.

Align

Hard Drive Configuration Options

Two 2.5" HDDs 

In a Double Bracket, Four HDD's Total, 

No Expansion Card

Two 2.5" Hard Drives 

and One Full-Height, 

Half-Length Expansion Card

One 3.5” Hard Drive 

and Low Profile

Expansion Card

Two 3.5" Hard Drives 

and No Expansion Card 

Note: Compatibility of add-on cards dependent on component height, etc.