background image

S

UPER

S

ERVER

 5015P-8(R)

S

UPER

S

ERVER

 5015P-T(R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER’S MANUAL

1.0b

   

S

UPER

®

Содержание SUPERSERVER 5015P-8

Страница 1: ...SUPERSERVER 5015P 8 R SUPERSERVER 5015P T R USER S MANUAL 1 0b SUPER...

Страница 2: ...r the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to com...

Страница 3: ...roduction The rst chapter provides a checklist of the main components included with the serv er system and describes the main features of the PDSMP 8 PDSMP i serverboard and the SC816S 400 R SC816T 40...

Страница 4: ...hapter when adding or removing processors or main memory and when recon guring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC816S 400 R SC816T 4...

Страница 5: ...v Preface Notes...

Страница 6: ...2 1 Choosing a Setup Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 2 4 Installing the System into a Rack 2 4 2 5 Checking the Serverboard Setup 2 8 2 6 Che...

Страница 7: ...nstalling Memory 5 7 5 6 Adding PCI Cards 5 9 5 7 Serverboard Details 5 10 PDSMP 8 PDSMP i Layout 5 10 PDSMP 8 PDSMP i Quick Reference 5 11 5 8 Connector De nitions 5 12 ATX Power Connector 5 12 Proce...

Страница 8: ...ns 5 22 Floppy Connector 5 22 IDE Connectors 5 23 SCSI Connectors 5 24 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6...

Страница 9: ...Running Setup 7 2 7 3 Main BIOS Setup 7 2 7 4 Advanced Setup 7 7 7 5 Security 7 18 7 6 Boot 7 20 7 7 Exit 7 21 Appendices Appendix A BIOS POST Messages A 1 Appendix B BIOS POST Codes B 1 Appendix C S...

Страница 10: ...Notes x SUPERSERVER 5015P 8 R 5015P T R User s Manual...

Страница 11: ...TEAC S B One 1 slim 8x DVD 24x CD ROM drive DVM PNSC 824 B Three 3 4 cm counter rotating chassis cooling fans FAN 0085 One 1 front control panel cable One 1 rackmount kit CSE PT51 Riser Cards see sec...

Страница 12: ...ts that can support up to 8 GB of unbuffered ECC or non ECC DDR2 667 533 400 SDRAM Memory can be installed in either a single or a dual channel interleaved con guration which requires modules of the s...

Страница 13: ...rnal SCSI port is also included on the PDSMP 8 ATI Graphics Controller Both serverboards feature an integrated ATI video controller based on the Rage XL graphics chip Rage XL fully supports sideband a...

Страница 14: ...See Section 5 6 for details Front Control Panel The SC816S 400 R SC816T 400 R s control panel provides you with system monitoring and control LEDs indicate UID system power HDD activity network activ...

Страница 15: ...FWH LPC I O PRI_IDE VRM 10 1 CTRL ADDR DATA UDMA 100 LPC PCI_32_BUS DDR2_667 533 VRM V10 1 SMBUS ATI VGA DIMM_CHA S ATA 300 4 x SATA CK410 CLK PXH MCH DIMM_CHB PORTS PCIE_x8 2 PCIE_x1 W83627HF FSB 106...

Страница 16: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 17: ...maged in any way If the server itself shows damage you should le a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 5015P 8 R 5015P T R...

Страница 18: ...rs should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend o...

Страница 19: ...mised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 20: ...ns that came with the rack unit you are using Identifying the Sections of the Rack Rails You should have received two rack rail assemblies in the rack mounting kit Each assembly consists of two sectio...

Страница 21: ...cket to the front side of the outer rail with two M4 screws and the long bracket to the rear side of the outer rail with three M4 screws Repeat these steps for the left outer rail Locking Tabs Both ch...

Страница 22: ...to the rack Do this by lining up the rear of the chas sis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to dep...

Страница 23: ...First determine how far the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove i...

Страница 24: ...he server To remove the system from the rack completely depress the locking tabs in the chassis rails push the right side tab down and the left side tab up to continue to pull the system out past the...

Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System...

Страница 26: ...to the system 3 Check the SCSI SATA disk drives Depending upon your system s con guration your system may have one or more drives already installed If you need to install SCSI SATA drives please refer...

Страница 27: ...Control Panel Buttons There are two push buttons located on the front of the chassis These are in order from left to right a UID button and a power on off button UID Depressing the UID unit identi er...

Страница 28: ...this LED off Overheat Fan Fail When this LED ashes it indicates a fan failure When on continuously on and not ashing it indicates an overheat condition which may be caused by cables obstructing the ai...

Страница 29: ...drive car rier indicates drive activity A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed Red The SAF TE compliant backplane act...

Страница 30: ...3 4 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...

Страница 31: ...s and the DVD ROM and oppy drives not necessary for SCSI and SATA drives When disconnecting power you should rst power down the system with the operating system and then unplug the power cords of all...

Страница 32: ...n Remove any jewelry or metal objects from your body which are excellent metal The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets Serverboar...

Страница 33: ...tistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its compon...

Страница 34: ...he chassis cover is in place when the 5015P 8 R 5015P T R is operating to ensure proper cooling Out of warranty damage to the 5015P 8 R 5015P T R system can occur if this practice is not strictly foll...

Страница 35: ...hat the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to...

Страница 36: ...CPU socket with load plate Socket Lever 2 Carefully lift the socket lever up to open the load plate Load Plate 3 Locate Pin 1 on the CPU socket Pin 1 is closest to the notched corner of the housing Pl...

Страница 37: ...s of the CPU to make sure that the CPU is properly installed 7 Use your thumb to gently press the lever down and lock it in the hook 8 If the CPU is properly installed into the socket the black plasti...

Страница 38: ...e screws which may damage the CPU 4 Finish the installation by fully tightening all four screws Heatsink Removal 1 Unscrew and remove the heatsink screws from in the sequence as show in the picture on...

Страница 39: ...nnect to the pin 1 locations If you are con guring the system keep the air ow in mind when routing the cables The following data cables with their serverboard connector locations noted should be conne...

Страница 40: ...red wire plugs into pin 1 as marked on the board The other end connects to the Control Panel printed circuit board located just behind the system status LEDs in the chassis See the Connector De nitio...

Страница 41: ...populate any number of DIMM slots Populating DIMM 1A and DIMM 1B and or DIMM 2A and DIMM 2B with memory modules of the same size and speed will result in dual channel two way interleaved memory which...

Страница 42: ...s To Install Insert module vertically and press down until it snaps into place Pay attention to the bottom notch To Remove Use your thumbs to gently push each release tab outward to free the DIMM from...

Страница 43: ...hen installing cards Begin by removing the top chassis cover Both riser cards are attached to a bracket that runs length wise through the chassis Remove the three screws that secure the riser cards to...

Страница 44: ...only If using a compact ash card in JIDE2 JIDE1 can only support a single device Battery JBT1 Mouse U320 SCSI CHB VGA KB COM1 LAN2 LAN1 USB0 1 BIOS 1UIPMI JWD JWOR Speaker Rage XL JPG1 PCI 1 100 MHz P...

Страница 45: ...onnection J43 ATX 20 Pin Power Connector J48 USB2 3 Headers J50 USB4 5 Headers JA1 JB1 SCSI Channel A SCSI Channel B Connectors JD1 Speaker Header JF1 Front Panel Control Header JFDD1 Floppy Disk Conn...

Страница 46: ...nnected to your power supply to provide adequate power supply to the system ATX Power 20 pin Connector Pin De nitions J43 Pin De nition Pin De nition 11 GND8 1 GND1 12 5V1 2 GND2 13 5V2 3 GND3 14 3 3V...

Страница 47: ...pins 11 and 12 of JF1 Attach the NIC cables to display net work activity Refer to the table on the right for pin de nitions HDD LED The HDD LED for IDE and SATA drives connection is located on pins 1...

Страница 48: ...ds Chassis Intrusion A Chassis Intrusion header is located at JL1 Attach the appropriate cable to inform you of a chassis intrusion UID Button UID LED A Unit Identi er button LED is located next to th...

Страница 49: ...n de nitions Universal Serial Bus Headers Two extra USB headers at J48 USB2 3 and J50 USB4 5 can be used for front side USB access You will need a USB cable to use these connections Refer to the table...

Страница 50: ...ing call to the modem when in suspend state See the table on the right for pin de nitions You must have a Wake On Ring card and cable to use this feature Speaker Connector Pin De nitions JD1 Pin Funct...

Страница 51: ...nt Bus header is located at JS10 Connect the ap propriate cable here to utilize SMB on your system SMB Header Pin De nitions JS10 Pin De nition 1 Data 2 Ground 3 Clock 4 No Connection Serial Ports One...

Страница 52: ...tead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First power down the system and unplug the power cord s 2 With the power disconn...

Страница 53: ...disable the onboard SCSI control ler The normal default position is on pins 1 2 to enable SCSI See the table on the right for jumper settings SCSI Enable Disable Jumper Settings JPA1 Jumper Setting D...

Страница 54: ...or disable the Power Force On function If enabled the power will always stay on automatically If disabled the de fault setting the user must press the power button to power on the system Power Force O...

Страница 55: ...er side of the chassis When you walk around to the other side of the rack the unit will then be easy to spot The LED will remain on until the UID button is pushed again The rear chassis UID at JPB1 is...

Страница 56: ...o connectors to provide for two oppy disk drives The connector with twisted wires always connects to drive A and the connector that does not have twisted wires always connects to drive B Floppy Drive...

Страница 57: ...7 4 Host Data 8 5 Host Data 6 6 Host Data 9 7 Host Data 5 8 Host Data 10 9 Host Data 4 10 Host Data 11 11 Host Data 3 12 Host Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17...

Страница 58: ...12 DB 6 46 DB 6 13 DB 7 47 DB 7 14 DB P 48 DB P 15 Ground 49 Ground 16 DIFFSENS 50 Ground 17 TERMPWR 51 TERMPWR 18 TERMPWR 52 TERMPWR 19 Reserved 53 Reserved 20 Ground 54 Ground 21 ATN 55 ATN 22 Groun...

Страница 59: ...To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally suf cient to protect your equipment from ESD damage Precautions...

Страница 60: ...ire plugs into pin 1 on both connectors Pull all excess cabling out of the air ow path The control panel LEDs inform you of system status See Chapter 3 System Interface for details on the LEDs and the...

Страница 61: ...Remove the top chassis cover while the system is still running to determine which of the two fan units has failed Then power down the system before replacing a fan Removing the power cord s is also r...

Страница 62: ...TA drives Proceed to the next step for instructions Note You must use standard 1 high SCSI SATA drives in the SuperServer 5015P 8 R 5015P T R DVD CD ROM Floppy Disk Drives For installing removing a DV...

Страница 63: ...w drive install it into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier Secure the drive to the carrier with six screws as shown...

Страница 64: ...ive Carrier Important All of the SCSI SATA drive carriers must remain in the drive bays to maintain proper cooling air ow Release Button 2 Installing removing hot swap SCSI SATA drives The SCSI SATA d...

Страница 65: ...ame time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full ac cess to the inside of the server With the chassis cover removed unplug the power a...

Страница 66: ...without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to replace a power supply module The redundant feature will keep the system up and running...

Страница 67: ...fore removing and replacing the power supply for whatever reason Removing Replacing the Power Supply 1 Removing the power supply First turn the power switch on the control panel off then unplug the po...

Страница 68: ...6 10 SUPERSERVER 5015P 8 R 5015P T R User s Manual Figure 6 5 Removing Replacing the Power Supply...

Страница 69: ...hen the computer is turned off a backup battery provides power to the BIOS ash chip enabling it to retain system parameters Each time the computer is powered on the computer is con gured with the valu...

Страница 70: ...e message shown below appears brie y at the bottom of the screen during the POST Power On Self Test press the Delete key to activate the main Setup menu Press the Delete key to enter Setup Note Please...

Страница 71: ...ey in the correct information in the appropriate elds Then press the Enter key to save the data System Date Using the arrow keys highlight the month day and year elds and enter the correct data Press...

Страница 72: ...to detected and placed in the Native IDE Mode Note The Enhanced mode is supported by the Windows 2000 OS or a later version When the SATA Controller Mode is set to Enhanced the following items will di...

Страница 73: ...f IDE hard drive The options are Auto which allows BIOS to automatically determine the hard drive s capacity number of heads etc a number from 1 39 to select a predetermined type of hard drive CDROM a...

Страница 74: ...is feature allows the user to enable or disable the function of 32 bit data transfer The options are Enabled and Disabled Transfer Mode Thisfeatureallowstheuserto selectthetransfermode TheoptionsareSt...

Страница 75: ...ting option using the arrow keys and pressing Enter All Advanced BIOS Setup options are described in this section Boot Features Access the submenu to make changes to the following settings Quick Boot...

Страница 76: ...act when power returns after an unexpected loss of power The options are Last State Stay off and Power On Watch Dog If enabled this option will automatically reset the system if the system is not acti...

Страница 77: ...e will allow the data stored in the base memory area block 512K 640K to be cached written into a buffer a storage area in the Static DRM SDROM or to be written into L1 L2 cache inside the CPU to speed...

Страница 78: ...to change the bus frequency for the devices installed in the slots indicated The options are Auto PCI 33 MHz PCI 66 MHz PCI X 66 MHz PCI X 100 MHz and PCI X 133 MHz Slot 1 PCI X 100 MHz ZCR Slot 2 PCI...

Страница 79: ...o select the type of interrupt to be activated as a result of an ECC error The options are None NMI Non Maskable Interrupt SMI System Management Interrupt and SCI System Control Interrupt Note This it...

Страница 80: ...ons are Default X14 X15 and X16 Hyper threading Available when supported by the CPU This setting allows you to Enable or Disable the function of hyper threading Enabling hyper threading results in inc...

Страница 81: ...information No Execute Mode Memory Protection Enable this feature to enable the functionality of Execute Disable Bit and allow the processor to classify areas in the memory where an application code...

Страница 82: ...for Serial Port A The options are IRQ3 and IRQ4 Serial Port B This setting allows you to decide how Serial Port B is controlled The options are Enabled user de ned Disabled and Auto BIOS or OS control...

Страница 83: ...ity It is not a setting View DMI Event Log Highlight this item and press Enter to view the contents of the event log Event Logging This setting allows you to Enable or Disable event logging ECC Event...

Страница 84: ...nd 115 2K Console Type This item allows you to choose from the available options to select the console type for console redirection The options are VT100 VT100 8bit PC ANSI 7bit PC ANSI VT100 VT UTF8...

Страница 85: ...of the system Fan Speed This item displays the speed of each onboard cooling fan Fan 1 Speed FAN 6 Speed Fan Speed Control Modes This feature allows the user to decide how the system controls the spee...

Страница 86: ...a supervisor password has been entered for the system User Password Is This displays whether a user password has been entered for the system Clear means such a password has not been used and Set means...

Страница 87: ...to Write Protect which protects the boot sector on the hard drive from having a virus written to it The other option is Normal Password on Boot This setting allows you to require a password to be ent...

Страница 88: ...t BIOS settings are described in this section Boot Priority Order Excluded from Boot Order Use the Up and Down Arrow Keys to select a device Use a key or a key to move the device up or down Use the f...

Страница 89: ...Discarding Changes Highlight this item and hit Enter to exit the BIOS Setup utility without saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load the defau...

Страница 90: ...7 22 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...

Страница 91: ...wer On Self Test POST the BIOS will check for problems If a prob lem is found the BIOS will activate an alarm or display a message The following is a list of such BIOS messages 1 repetitive long beep...

Страница 92: ...A 2 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...

Страница 93: ...attempt to initialize video and write the error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes POST Code Description 0...

Страница 94: ...own 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced con guration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot 42h Initiali...

Страница 95: ...t 80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Con gure non MCD IDE controllers 84h Detect and install external para...

Страница 96: ...rminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS B9h Prepare Boot BAh Initialize SMBIOS BBh Initialize PnP Option ROMs BCh Clear parity checkers BDh Display MultiBoot me...

Страница 97: ...e EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F5h Clea...

Страница 98: ...B 6 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...

Страница 99: ...support Windows XP 2000 2003 Operating Systems Serial ATA SATA Serial ATA SATA is a physical storage interface that uses a single cable with a minimum of four wires to create a point to point connecti...

Страница 100: ...ange the HDD partition size without any data Con guring BIOS settings for SATA RAID Functions Native Mode 1 Press the Del key during system bootup to enter the BIOS Setup Utility Note If it is the rst...

Страница 101: ...rs after Power On Self Test b When you see the above screen press the Ctrl and the I keys simultane ously to have the main menu of the SATA RAID Utility appear Note All graphics and screen shots shown...

Страница 102: ...drive and press Space to select it A triangle appears to con rm the selection of the drive f Use the Up Arrow Down Arrow keys to selet the stripe size ranged from 4 KB to 128 KB for the RAID 0 array...

Страница 103: ...t the previous menu c When RAID Level item is highlighted press the Up Arrow Down Arrow keys to select RAID 1 Mirror and hit Enter d When the Capacity item is highlighted enter your RAID volume capaci...

Страница 104: ...rrow Down Arrow keys to select the stripe size from 4 KB to 128 KB for your RAID 10 and hit Enter The default setting is 6 4KB Note For a server please use a lower stripe size and for a multimedia sys...

Страница 105: ...drive and press Space to select it A triangle appears to con rm the selection of the drive f Use the Up Arrow Down Arrow keys to select the stripe size ranged from 4 KB to 128 KB for the RAID 5 array...

Страница 106: ...disk drives when deleting a RAID set a From the main menu select item2 Delete RAID Volume and press Enter b Use the Up Arrow Down Arrow keys to select the RAID set you want to delete and press Del A W...

Страница 107: ...ID set drive A Warning message displays d Press Y to reset the drive or type N to go back to the main menu Exiting the Intel Matrix Storage Manager Utility a From the main menu select item4 Exit and p...

Страница 108: ...RAID Controller from the list indicated in the XP 2000 2003 Setup Screen and press the Enter key f Press the Enter key to continue the installation process If you need to specify any additional devic...

Страница 109: ...st re boot the system before moving on to the next item on the list You should install everything here except for the SUPER Doctor utility and the LAN SCSI driver diskettes which are optional The bott...

Страница 110: ...proceed the installation in the welcoming window 15 Intel ICH5R Serial ATA RAID Introduction The InstallShield Wizard will begin automatically for installation showed as following Click on the Next bu...

Страница 111: ...marked Yes on the screen and the following screen will appear Intel ICH5R Serial ATA RAID Introduction 16 After reading the license agreement in the following window click Y es button to continue Sel...

Страница 112: ...the XP 2000 2003 Operating System is installed please read the Re adme text les for the instructions to use the SATA RAID Utility in the Windows XP 2000 2003 OS environment 17 Intel ICH5R Serial ATA R...

Страница 113: ...to Page C 14 Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme les for each item Click the computer icons to the right of these items to...

Страница 114: ...Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system Supero Doctor III displays crucial system informatio...

Страница 115: ...ed from our Website at ftp ftp supermicro com utility Supero_Doctor_III You can also download SDIII User s Guide at http www supermicro com PRODUCT Manuals SDIII UserGuide pdf For Linux we will still...

Страница 116: ...C 18 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...

Страница 117: ...upporting up to 8 GB of unbuffered ECC non ECC DDR2 667 533 400 SDRAM Note See the memory section in Chapter 5 for details SCSI Controller 5015P 8 R AIC 7902 for dual channel Ultra320 SCSI Serial ATA...

Страница 118: ...one 57 lbs 25 9 kg 5015P 8R TR Gross Bare Bone 60 lbs 27 3 kg System Cooling Three 3 paired sets of 40 mm counter rotating cooling fans fan speed controlled by BIOS setting System Input Requirements A...

Страница 119: ...N 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety EN 60950 IEC 60950 Compliant UL Listed USA CUL Listed Canada TUV Certi ed Germany CE Marking Europe California Best Management Practices Regu...

Страница 120: ...D 4 SUPERSERVER 5015P 8 R 5015P T R User s Manual Notes...