USER’S MANUAL
Revision 1.0b
SuperServer
®
4029GP-TVRT
Страница 1: ...USER S MANUAL Revision 1 0b SuperServer 4029GP TVRT...
Страница 2: ...industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful int...
Страница 3: ...nd utilities https www supermicro com wftp Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support superm...
Страница 4: ...n 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerations 19 Ambient Operating Temperature 19 Airflow 19 Mechanic...
Страница 5: ...34 Memory Population Sequence 34 DCPMM Population Table 24 Slots based on the 82xx 62xx 52xx 42xx 37 Installing Memory 39 Motherboard Battery 40 3 4 Graphic Processor Units 41 GPU Mapping 41 Installi...
Страница 6: ...Setup Utility 70 6 2 Main Setup 70 6 3 Advanced Setup Configurations 72 6 4 Event Logs 98 6 5 IPMI 100 6 6 Security 103 6 7 Boot 106 6 8 Save Exit 109 Appendix A BIOS Error Codes Appendix B Standardi...
Страница 7: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...
Страница 8: ...n a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fi...
Страница 9: ...DC Persistent memory modules DCPMM Chipset Intel C621 Expansion Slots Six x16 PCI E low profile slots depicted on page 11 Storage Drives Sixteen hot swap 2 5 drive bays for up to eight SAS3 SATA3 HDDs...
Страница 10: ...e main power switch applies or removes primary power to the server standby power is maintained It is green when the system is operating It is amber when the system is off but the power supplies are st...
Страница 11: ...I E x16 from CPUs in motherboard tray 5 Asset Tag BMC Password sticker A slide out tab for an asset tag also the sticker showing the default IPMI BMC ADMIN password is on the underside of the tab Figu...
Страница 12: ...ules with included system fans PWS 1 PWS 4 A D System Fan FAN_MOD 1 to FAN_MOD 4 respectively A D Figure 1 5 Chassis Rear View Rear Features The illustration below shows the features included on the r...
Страница 13: ...USB1 PWR_SW1 SW2 SW1 JP2 BIOS X11DGO T Rev 1 01 BAR CODE MAC CODE SAN MAC IPMI CODE BIOS LICENSE LEDBMC CPU2 SLOT2 PCI E 3 0 X16 M 2 P2 RAID KEY 1 CPU1 SLOT1 PCI E 3 0 X16 PWR_BUTTON RESET_BUTTON JBT1...
Страница 14: ...Master Port for NVMe side band connections CN15 OCuLink connector supported by CPU2 PCI E Port 3 15 8 CN16 OCuLink connector supported by Slot2 PCI E 7 0 CN17 OCuLink connector supported by Slot2 PCI...
Страница 15: ...ible VGA port LED Description State Status HDD_LED1 HDD Activity LED Blinking Green HDD active LED1 M 2 Slot1 M 2 P1 Activity LED On M 2 Slot 1 active LED2 M 2 Slot2 M 2 P2 Activity LED On M 2 Slot 2...
Страница 16: ...tFlash DDR4 LAN 10G UPI CPU2 CPU1 P2 P2 UPI PCI E X16 Slot E 1 F 2 B 1 C 2 DDR4 B 2 PCI E X16 G3 D 1 C 1 F 1 E 2 D 2 RJ45 2x in Front IO 1x Internal Type A M 2 L 1 H 2 J 2 H 1 G 2 G 1 PCI E X16 G3 J 1...
Страница 17: ...itch is root to two SXM2 modules and one PCI E3 0 x16 slot A fast network expansion card installed on the riser card affords very high speeds Data can go from GPU to the PLX to the NIC without going t...
Страница 18: ...k Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...
Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...
Страница 20: ...ch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The follow...
Страница 21: ...w of the Rack Rails The package includes two rail assemblies Each is specifically designed for the left or right side of the chassis and so marked Each rail consists of two sections a front section wh...
Страница 22: ...oaded pegs snap into the rack holes Secure the rail to the rack with screws 3 Pull out the rear section of the outer rail adjusting the length until it fits within the posts of the rack and align the...
Страница 23: ...nto the bottom lip of the rail Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you slide the unit out for servicing Failure to stabilize...
Страница 24: ...follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non...
Страница 25: ...are accessible by removing the appropriate tray Removing a Component Tray 1 Begin by removing power from the system as described in Section 3 1 2 On the outside edges of the tray pull down on both re...
Страница 26: ...ay and the GPU tray each have a cover that can be removed to access internal components Removing the Tray Cover Slide the release buttons on both sides of the cover toward the middle of the tray and l...
Страница 27: ...ction Unplug the AC power cord from all power supplies after shutting down the system Check that the plastic protective cover is on the CPU socket and none of the socket pins are bent If they are cont...
Страница 28: ...al 28 Overview of the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier and the processor Heatsink with Thermal Grease Processor Carrier Processor Pro...
Страница 29: ...w 2 Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3...
Страница 30: ...carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of the a...
Страница 31: ...tion This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remo...
Страница 32: ...essure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tightening the screws 4 Examine all...
Страница 33: ...RX4 N A 4H 128GB LRDIMM QRx4 32 GB 64 GB LRDIMM 3Ds QRx4 N A 2H 64GB 8Rx4 N A 4H 128 GB DDR4 Memory Support for 82xx 62xx 52xx 42xx 32xx Processors Type Ranks Per DIMM and Data Width DIMM Capacity GB...
Страница 34: ...xed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in the sa...
Страница 35: ...1 CPU2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMM...
Страница 36: ...DIMMA1 P1 DIMMA2 P1 DIMMD2 P1 DIMME2 P1 DIMMD1 P1 DIMME1 P1 DIMMF2 P1 DIMMF1 P1 DIMMB1 P1 DIMMC1 P1 DIMMB2 P1 DIMMC2 CPU2 P2 DIMMA1 P2 DIMMA2 P2 DIMMD2 P2 DIMME2 P2 DIMMD1 P2 DIMME1 P2 DIMMF2 P2 DIMM...
Страница 37: ...DCP 1 1 1 4 DCP 16 DIMM AD DCP M1 M1 M1 M1 M1 M1 M1 M1 DCP 2 2 1 AD App Direct MM Memory Mode M1 M2 M3 DRAM see Legend below Asymmetric Population for Each CPU DCP DIMMs Modes P1 P2 DIMMF1 P1 P2 DIMM...
Страница 38: ...x 42xx platform For each individual population use the same DDR4 DIMM in all slots For each individual population sockets are normally symmetric with exceptions for one DCPMM per socket and one DCPMM...
Страница 39: ...wer from the system as described in Section 3 1 Follow the memory population sequence in the preceding table 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release...
Страница 40: ...nder the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a dama...
Страница 41: ...GPU Mapping Table IPMI Label GPU1 GPU2 GPU3 GPU4 GPU5 GPU6 GPU7 GPU8 OS GPU0 GPU1 GPU2 GPU3 GPU4 GPU5 GPU6 GPU7 Bus No 1A 00 0 1B 00 0 3D 00 0 3E 00 0 88 00 0 89 00 0 B2 00 0 B3 00 0 The GPU connecti...
Страница 42: ...that line up with holes in the add on board They allow only the correct orientation of the GPU 4 Secure the GPU with eight screws Screw the four inside screws first in a diagonal pattern then the four...
Страница 43: ...43 Chapter 3 Maintenance and Component Installation Figure 3 6 GPU Heatsinks Installed...
Страница 44: ...ng the GPU Air Shroud 1 Power down the system pull the GPU chassis tray from the main chassis and remove the cover 2 Noting the front and rear sides of the air shroud insert the sides of the air shrou...
Страница 45: ...nding on the number of NVMe drives one or two PCI E connectors are used and therefore not available for expansion cards Note Enterprise level hard disk drives are recommended for use in Supermicro ser...
Страница 46: ...ivity LED Blue Solid On SAS NVMe drive installed Blue Blinking I O activity Status LED Red Solid On Failure of drive with RSTe support Red Blinking at 1 Hz Rebuild drive with RSTe support Red Blinking...
Страница 47: ...oward the rear of the carrier Align the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to t...
Страница 48: ...d Expansion Cards The two PCI E slots on the motherboard also provide support for NVMe thus limiting slots for expansion cards in the following combinations One or two NVMe drives Condition 2 leave on...
Страница 49: ...ckplane as shown in the diagram above One OCuLink cable is required for each pair of NVMe drives 2 BIOS setup a Setup IIO bifurcation Set IIO2 to x8x4x4 or x4x4x4x4 depending on the number of NVMe dri...
Страница 50: ...tion Enable VMD mode and corresponding port 3A 3B and Save and Exit Advanced Chipset Config North Bridge IIO Config VMD techology c VMD Management Re enter to setup menu and you may get the two disks...
Страница 51: ...nd Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture The 4029GP TVRT server h...
Страница 52: ...of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD Shows the temperatures of all NVMe drives as in Figure 3 4 IPMI Server Health Sensor Reading NVME_S...
Страница 53: ...to power down the system when switching fans Changing a System Fan 1 Determine which fan has failed using IPMI or observation 2 If the fan unit includes an AC power plug remove the power cord 3 Lift...
Страница 54: ...ithout powering down the system Replace with the same model Replacement modules can be ordered directly from Supermicro An amber light on the power supply is illuminated when the power is switched off...
Страница 55: ...e x16 low profile Installing Expansion Cards 1 Power down the system as described in Section 3 1 2 Slide out the chassis motherboard tray or GPU tray and remove the cover Section 3 2 3 Remove the scre...
Страница 56: ...SuperServer 4029GP TVRT User s Manual 56 Expansion Card Expansion Cards 2 Figure 3 14 Expansion Cards on GPU Board supported by PLX Expansion Card...
Страница 57: ...ving components 4 1 Power Connections Two proprietary power connectors JPWR1 JPWR2 located on the midplane provide main power for system use In addition three 8 pin power connectors JPW11 JPW12 JPW13...
Страница 58: ...is used to connect a Trusted Platform Module TPM Port 80 a security device that supports encryption and authentication in storage drives It allows the motherboard to deny access if the TPM associated...
Страница 59: ...3 7 0 and used as CPU1 Master Port for NVMe side band connections CN11 OCuLink connector supported by CPU1 PCI E Port 3 15 8 CN12 OCuLink connector supported by Slot1 PCI E 7 0 CN13 OCuLink connector...
Страница 60: ...perServer 4029GP TVRT User s Manual Figure 4 1 Front Input Output Ports Input Output Ports No Description No Description 1 VGA 4 USB 1 USB 3 0 2 LAN1 5 USB 2 USB 3 0 3 LAN2 6 IPMI LAN 4 3 Ports 3 1 5...
Страница 61: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...
Страница 62: ...e or disable LAN Port1 and LAN Port2 The default setting is Enabled LAN1 LAN2 Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Management Engine ME Recovery...
Страница 63: ...The default setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Pins...
Страница 64: ...ts each have two LEDs One LED indicates activity when flashing while the other LED may be green amber or off to indicate the speed of the connection LAN LED Connection Speed Indicator LED Color Defini...
Страница 65: ...upermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive o...
Страница 66: ...oad the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID ch...
Страница 67: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...
Страница 68: ...nagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...
Страница 69: ...settings that are related to IPMI For general documentation and information on IPMI visit our website at http www supermicro com products nfo IPMI cfm BMC ADMIN User Password For security each system...
Страница 70: ...tion is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list...
Страница 71: ...r the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 3...
Страница 72: ...figuration Quiet Boot Use this feature to select the screen between displaying POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM lo...
Страница 73: ...boot device after an initial boot failure Select Legacy Boot to allow the BIOS to automatically reboot the system from a Legacy boot device after an initial boot failure The options are Disabled Legac...
Страница 74: ...cified by the user Enter 0 to enable all cores available in the processor Enter bit0 to disable CPU Core 0 Enter bit1 to disable CPU Core 1 Please note that the maximum of 24 CPU cores are currently a...
Страница 75: ...e the DCU Data Cache Unit streamer prefetcher will prefetch data streams from the cache memory to the DCU Data Cache Unit to speed up data accessing and processing for CPU performance enhancement The...
Страница 76: ...he performance is the higher the power consumption will be Select Max Power Efficient to maximize power saving however system performance may be substantially impacted because limited power use decrea...
Страница 77: ...ow the processor core to control its C State setting automatically and independently The options are Enable and Disable CPU C6 Report Select Enable to allow the BIOS to report the CPU C6 state ACPI C3...
Страница 78: ...L1 Level 1 link The options are Disable Enable and Auto IO Directory Cache IODC Select Enable for the IODC I O Directory Cache to generate snoops instead of generating memory lockups for remote IIO I...
Страница 79: ...Data Scrambling for NVDIMM Select Enable to enable data scrambling for onboard NVDIMM memory to enhance system performance and security The options are Auto Disable and Enable Data Scrambling for DDR4...
Страница 80: ...ks and corrects single bit or multiple bit 4 bit max memory faults that affect an entire single x4 DRAM device SDDC Plus One is the enhanced feature to SDDC SDDC 1 will spare the faulty DRAM device ou...
Страница 81: ...ring electric tuning The options are Disable and Enable CPU1 Configuration CPU2 Configuration IOU0 IIO PCIe Br1 This feature configures the PCI E Bifuraction setting for a PCI E port specified by the...
Страница 82: ...mum payload value for a PCI E device specified by to user to enhance system performance The options are Auto 128B and 256B Socket 1 PCI E Br0D00F0 Port 0 Socket 1 PCI E Br5D00F0 MCP1 Available for CPU...
Страница 83: ...Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to the VMM Virtual Machine Monitor through the DMAR ACPI tables This feature offers fully protected I O r...
Страница 84: ...options are Disable and Enable Hot Plug Capable Available when the device is detected by the system Use this feature to enable hot plug support for PCI E root ports 3A CN1 P1 to 3A CN2 P2 The options...
Страница 85: ...tions only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI...
Страница 86: ...led Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID Note This ite...
Страница 87: ...er Version PCI Devices Common Settings Above 4G Decoding Available if the system supports 64 bit PCI decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address T...
Страница 88: ...the PCI E slot specified by the user Select Legacy to allow the user to boot the computer using a legacy device installed on the PCI E slot specified by the user The options are Disabled Legacy and EF...
Страница 89: ...wait time in seconds for the BIOS ROM to detect the LAN media Internet connection or LAN port The default is 1 Super IO Configuration Super IO Chip AST2500 Serial Port 1 Configuration Serial Port Sele...
Страница 90: ...d IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Attribute Select SOL to use COM Port 2 as a Serial_Over_LAN SOL port for console redirection The options are COM and SOL Serial Port Console Redirectio...
Страница 91: ...our data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if...
Страница 92: ...Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Sele...
Страница 93: ...e Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 S...
Страница 94: ...ction and SOL Console Redirection Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to add co...
Страница 95: ...ding smooth playback and reducing the dependency on other timestamp calculation devices such as an x86 RDTSC Instruction embedded in the CPU The High Performance Event Timer is used to replace the 825...
Страница 96: ...e the cryptographic algorithm to define a constant key or a fixed set of keys to be used for initial system boot This early boot code is shipped with the platform and is included in the list of public...
Страница 97: ...ermitting the platform software to use the TPM The options are Enabled and Disabled PH Platform Hierarchy Randomization for TPM Version 2 0 and above Select Enabled for Platform Hierarchy Randomizatio...
Страница 98: ...bled and Disabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are No...
Страница 99: ...0 to 99 The default setting is 60 Note Please reboot the system for the changes to take effect Custom Options Log OEM Codes This feature Enables or Disables the logging of EFI Status Codes as OEM Cod...
Страница 100: ...us This feature indicates IPMI status of your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabl...
Страница 101: ...on This feature displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is Dedicated LAN Current Conf...
Страница 102: ...rce Use this feature to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If D...
Страница 103: ...this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup for th...
Страница 104: ...ettings The options are Enabled and Disabled Enroll All Factor Default Keys Select Yes to install all manufacturer defaults to configure the following system security settings The options are Yes and...
Страница 105: ...Erase Forbidden Signatures This feature allows the user to enter and configure a set of values to be used as Forbidden Signatures for the system These values also indicate the size the keys numbers an...
Страница 106: ...EFI OS when the Legacy OS fails The options are Enabled and Disabled Fixed Boot Order Priorities This feature prioritizes the order of a bootable device from which the system will boot Press Enter on...
Страница 107: ...s Enter to create the new boot option in the boot priority list Delete Boot Option Use this feature to select a boot device to delete from the boot priority list Delete Boot Option Use this feature to...
Страница 108: ...n Use this item to select a boot driver to delete from the boot priority list Delete Drive Option Select the target boot driver to delete from the boot priority list UEFI Application Boot Priorities B...
Страница 109: ...and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer...
Страница 110: ...e As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults...
Страница 111: ...corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No m...
Страница 112: ...or assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Thes...
Страница 113: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...
Страница 114: ...ken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...
Страница 115: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 116: ...tes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l inst...
Страница 117: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 118: ...abels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Wa...
Страница 119: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 120: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 121: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 122: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 123: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 124: ...dvertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques c...
Страница 125: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 126: ...ale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accord...
Страница 127: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 128: ...estornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient t...
Страница 129: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 130: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 131: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 132: ...IMM DDR4 288 pin ECC up to 2933 MHz modules also supports Non Volatile DIMM NVDMMM Intel Optane DC Persistent memory modules DCPMM SATA Controller On chip Intel C621 controller Storage Drives Sixteen...
Страница 133: ...operating Temperature 40 to 60 C 40 to 140 F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions...
Страница 134: ...e The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...
Страница 135: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...
Страница 136: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed w...
Страница 137: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...
Страница 138: ...terrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power su...
Страница 139: ...urpose you can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2...
Страница 140: ...tem remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellanous tab then the Troub...
Страница 141: ...id Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise In...
Страница 142: ...JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd part...
Страница 143: ...uration North Bridge IIO Configuration Intel VMD Technology CPU1 CPU2 5 Enable the VMD according to the following rules For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used...
Страница 144: ...AID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure F 4 12 Se...
Страница 145: ...e device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215...
Страница 146: ...146 SuperServer 2029BT Hxxx User s Manual Appendix G BSMI Chinese Safety Warnings 150 3...
Страница 147: ...ence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the...