Chapter 6: Advanced Chassis Setup
6-11
6-8 Installing the Serverboard
I/O Shield
The I/O shield holds the serverboard ports in place. The I/O shield does not require
installation (see Figure 6-10).
Permanent and Optional Standoffs
Standoffs prevent short circuits by creating space between the serverboard and the
chassis surface. The chassis includes permanent standoffs in locations
used by the serverboards. These standoffs accept the rounded Phillips head screws
included in the accessories packaging.
Some serverboards require additional screws for heatsinks, general components
and/or non-standard security. Optional standoffs are used for these serverboards.
To use an optional standoff, you must place a hexagonal screw through the bottom
the chassis and secure the screw with the hexagonal nut (rounded side up).
Depending upon the configuration of the serverboard being used, it is also possible
that some of the optional standoffs which are pre-installed in the chassis, may need
to be removed.
Installing the Serverboard (Figure 6-11 and 6-12)
1. Review the documentation that came with your serverboard. Become
familiar with component placement, requirements, precautions, and cable
connections.
2. Disconnect the AC power cord from any power source.
3. Pull the serverboard node drawer out of the back of the chassis (Figure 6-11).
4. Remove the expansion card brackets:
3a. Remove screw securing the expansion card bracket to the back of the
node drawer.
3b. Lift the bracket out of the node drawer.
5. Lay the serverboard in the node drawer aligning the standoffs with the
serverboard.
6. Secure the serverboard to the node drawer using the rounded, Phillips head
screws included for this purpose.
7. Install the adapter card associated with the serverboard if the chassis is a
hot-swappable version. Refer to the next section for instructions on installing
the adapter card
8. Secure the CPU(s), heatsinks, and other components to the serverboard as
described in the serverboard documentation.
Содержание SUPERSERVER 2028TP-DTFR
Страница 1: ...USER S MANUAL Revision 1 0a SUPERSERVER 2028TP DTR 2028TP DTTR 2028TP DTFR...
Страница 5: ...v Notes Table of Contents...
Страница 10: ...x Notes SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL...
Страница 18: ...1 8 SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL Notes...
Страница 30: ...SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL 3 4 Notes...
Страница 50: ...4 20 SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL Notes...
Страница 81: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing...
Страница 87: ...Chapter 6 Advanced Chassis Setup 6 13 Figure 6 12 Installing the Serverboard in the Serverboard Node Drawer...
Страница 94: ...6 20 SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL Notes...
Страница 136: ...A 2 SUPERSERVER 2028TP DTR DTTR DTFR USER S MANUAL Notes...
Страница 139: ...B 3 Appendix B System Specifications Notes...