81
Chapter 6: Optional Components
6.4 Power Supply Modules
Power Supply Module Options
Watts
Part Number
80Plus Level
1200
PWS-1K24A-1R (default)
Titanium
1600
PWS-1K63A-1R
Titanium
2600
PWS-2K63A-1R
Titanium
Figure 6-1. Cable Management Arm
6.5 Cable Management Arm
The system supports a cable management arm (CMA), which keeps the rear cables organized
and clear of the rail mechanisms when the system is extended out the front of the rack for
maintenance.
The CMA attaches to the rack mounting rails using four connectors. They are labeled on the
connectors 1, 2, 3, and 4.
Installing the Cable Management Arm
1. Slide CMA connector #1 forward onto the two posts on the rear of the right
inner
rail
(right side when viewed from the front). It snaps into place.
2. Slide CMA connector #2 forward onto the two posts on the rear of the right
middle
rail. It
snaps into place.
Cable Arm Details
Optional Part Part Number
Description
Cable Arm
MCP-290-00168-0N
7.5" deep cable arm
Rail Set
MCP-290-11901-0N
41.2" rails (optimized
for 1200 mm deep
racks)