![Supermicro SuperServe 1019D-14CN-FHN13TP Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/supermicro/superserve-1019d-14cn-fhn13tp/superserve-1019d-14cn-fhn13tp_user-manual_1404470044.webp)
44
SuperServer 1019D-(4C/14CN/16C-)FHN13TP User's Manual
Power SMB (I
2
C) Header
The Power System Management Bus (I
2
C) connector (JPI2C1) monitors the power supply.
Refer to the table below for pin definitions.
Power SMB Header
Pin Definitions
Pin#
Definition
1
Clock
2
Data
3
PMBUS_Alert
4
Ground
5
NC
4.2 Headers and Connectors
Fan Headers
The X11SDW- 4C -TP13F, X11SDW- 8C -TP13F, X11SDW-14CNT-TP13F, and
X11SDW-16C-TP13F motherboards have six 4-pin fan headers (FAN1 - FAN4, FANA, FANB).
These headers are backwards-compatible with the traditional 3-pin fans. However, fan speed
control is available for 4-pin fans only by Thermal Management via the IPMI 2.0 interface.
Refer to the table below for pin definitions.
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable
from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to
the table below for pin definitions.
Chassis Intrusion
Pin Definitions
Pin#
Definition
1
Intrusion Input
2
Ground
Fan Header
Pin Definitions
Pin#
Definition
1
Ground (Black)
2
2.5A/+12V (Red)
3
Tachometer
4
PWM_Control
Fan Zone
Pin Definitions
Zone
1
2
Fan #
FAN1/2/3/4
FANA/B