Chapter 6: Advanced Chassis Setup
6-7
6-8 Removing and Installing the Backplane
The SC217 chassis backplane is located behind the hard drives and in front of
the front system fans. Although backplane failure rarely occurs, in the event of a
backplane failure, follow the instructions below.
Removing the Backplane
Removing the Backplane from the Chassis
1. Power down and unplug the system from any power source.
2. Remove the chassis cover.
3. Disconnect the cabling to the backplane.
4. Remove all of the hard drive carriers from the front of the chassis.
5. Remove the fi ve upper screws at the top of the backplane and the screw from
the side of the chassis, as indicated by the arrows below (Figure 6-6).
6. Remove screw from the side of the chassis
Figure 6-6. Removing the Screws at the Top of the Backplane
1
5
1
6
Содержание Supero SUPERSERVER 2027PR-DTFR
Страница 1: ...SUPERSERVER 2027PR DTR 2027PR DTFR 2027PR DTTR SUPER USER S MANUAL Revision 1 0...
Страница 5: ...v SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL Notes...
Страница 10: ...x Notes SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL...
Страница 34: ...SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL 3 4 Notes...
Страница 84: ...5 30 SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL Notes...
Страница 102: ...6 18 SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL Notes...
Страница 140: ...A 2 SUPERSERVER 2027PR DTR DTFR DTTR USER S MANUAL Notes...
Страница 143: ...B 3 Appendix B System Specifications Notes...