Chapter 6: Advanced Chassis Setup
6-3
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the
remaining fans will ramp up to full speed. Replace any failed fan at your earliest
convenience with the same type and model (the system can continue to run with
a failed fan).
Replacing a System Fan (Figure 6-2)
If the BIOS is not being utilized to determine which fan has failed, open the
1.
top cover of the chassis while the system is running to locate the position of
the failed fan. Never run the server for an extended period of time with the
top cover open.
Turn off the power to the system and unplug the AC power cord.
2.
Remove the failed fan's wiring from the backplane.
3.
Remove the four pins securing the fan to the fan tray.
4.
Lift the failed fan from the fan tray and out of the chassis.
5.
Place the new fan into the vacant space in the fan tray, while making sure
6.
the arrows on the top of the fan (indicating air direction) point in the same
direction as the arrows on the other fans in the same fan tray.
Reconnect the fan wires to the exact same chassis fan headers as the
7.
previous fan.
Reconnect the AC power cord, power up the system and check that the fan is
8.
working properly before replacing the chassis cover.
Figure 6-2. Removing a Fan from the Fan Tray
Содержание Supero A+ SERVER 1042G-TF
Страница 1: ...SUPER USER S MANUAL Revision 1 0d A SERVER 1042G TF...
Страница 5: ...v Preface Notes...
Страница 14: ...1 6 A SERVER 1042G TF User s Manual Notes...
Страница 30: ...3 4 A SERVER 1042G TF User s Manual Notes...
Страница 67: ...Chapter 6 Advanced Chassis Setup 6 5 Figure 6 3 Removing a Hard Drive Carrier 1 1 1 2...
Страница 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Installing the Air Shroud 4 1 4 1 5...
Страница 88: ...A 2 A SERVER 1042G TF User s Manual Notes...