SuperDoctor

®

 5

The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based 
interface for Windows and Linux operating systems. The program monitors such system health 
information as CPU temperature, system voltages, system power consumption, fan speed, 
and provides alerts via email or Simple Network Management Protocol (SNMP).
SuperDoctor 5 comes in local and remote management versions and can be used with Nagios 
to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM 
Server), you can remotely control power on/off and reset chassis intrusion for multiple systems 
with SuperDoctor 5 or IPMI. SuperDoctor 5 Management Server monitors HTTP, FTP, and 
SMTP services to optimize the efficiency of your operation.

Note:

 The default User Name and Password for SuperDoctor 5 is ADMIN / ADMIN.

Figure 3-3. SuperDoctor 5 Interface Display Screen (Health Information)

Содержание SuperBlade SBI-610P-1C2N

Страница 1: ...USER S MANUAL Revision 1 0 SuperBlade Server SBI 610P 1C2N SBI 610P 1T2N...

Страница 2: ...ss A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s in...

Страница 3: ...ivers and utilities https www supermicro com wdl Product safety info https www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support...

Страница 4: ...g Up or Down 16 2 4 Processor and Heatsink Installation 17 The Processor Carrier Assembly 18 The Processor Heatsink Module PHM 20 Installing the PHM into the CPU Socket 21 Removing the PHM from the CP...

Страница 5: ...ir Flow 48 Overheating 48 3 4 Where to Get Replacement Components 49 3 5 Returning Merchandise for Service 49 Chapter 4 Motherboard Connections 4 1 Power Connections 50 Quick Reference 51 System Block...

Страница 6: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 7: ...atures of the SBI 610P 1 C T 2N blade server It is based on the B12SPE CPU 25G P motherboard Models System Storage Type Add on Module SBI 610P 1C2N SAS NVMe hybrid ports AOM BPNIO SCE2 SBI 610P 1T2N S...

Страница 8: ...set Intel C621A Memory 16 slots for up to 4TB of DDR4 ECC RDIMM LRDIMM LRDIMM 3DS memory with speeds of up to 3200MHz Size Up to 256GB at 1 2V Storage Drives Two hot swap 2 5 hybrid bays for SBI 610P...

Страница 9: ...ber blinks Before the BMC is ready blinks until every node is ready 3 KVM UID LED Steady blue Indicates that KVM has been initialized Flashing blue Unit IDentifier indicator The UID function is activa...

Страница 10: ...rs 2 Storage Drives Two hot swap 2 5 drive bays for NVME SAS or SATA the drive carriers display status lights 3 Latch Levers Levers for two latches that secure the blade in the enclosure 4 Service Ass...

Страница 11: ...11 Chapter 1 Introduction 1 5 Components Figure 1 3 Components Labeled SBI 610P 1C2N model shown 1 6 4 3 2 8 7 5 9 10 9...

Страница 12: ...torage card socket 6 GPU Bay Two PCIe slots supporting up to two GPUs 7 Mezzanine Network mezzanine add on card 8 Bridge Front I O card SAS controller for SBI 610P 1C2N two optional M 2 slots for SBI...

Страница 13: ...ems may be mixed together in the same blade enclosure 2 1 Unpacking the System Inspect the box the system was shipped in and note if it was damaged in any way If any equipment appears damaged please f...

Страница 14: ...cking lever away from the center of the blade until the blade unlocks from the enclosure 3 Use the locking levers to pull the blade from the enclosure Figure 2 1 Blade Locking Levers 2 2 Installing or...

Страница 15: ...tial cover can be removed if necessary To remove the cover remove the screws as illustrated below and lift it off To replace the cover fit the edges of the cover into the slots on the blade and replac...

Страница 16: ...de unit Use IPMIView or the browser based management utility to power down requires Operator or Admin privileges on the CMM Use SMCIPMItool when connected to the CMM to power down requires Operator or...

Страница 17: ...plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the l...

Страница 18: ...g down Locate the gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown below These triangles indicate the location of pin 1 Latch Latc...

Страница 19: ...processor under latch 1 on the carrier and then press the other end down until it snaps into latch 2 and is properly seated on the carrier Processor Carrier Assembly Top View Processor Carrier Assembl...

Страница 20: ...ote the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 On the processor carrier assembly find pin 1 as noted by the triangles Hold the process...

Страница 21: ...llation and Setup Installing the PHM into the CPU Socket 1 Remove the plastic protective cover from the CPU socket Gently squeeze the grip tabs then pull the cover off CPU Socket with Plastic Protecti...

Страница 22: ...asteners a b c d on the CPU socket 3 Locate four PEEK nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown below 4 Check that the rotating wires 1 2 3 4 are in the unlatched position...

Страница 23: ...the CPU socket making sure that each nut is properly aligned with its corresponding threaded fastener Latched State Top View 7 Press all four rotating wires outward to latch the PHM onto the CPU socke...

Страница 24: ...m is shut down and all AC power cords are unplugged 1 Use a t30 bit screwdriver to loosen the four PEEK nuts on the heatsink in the sequence of A B C and D 2 Press the four rotating wires inward to un...

Страница 25: ...r Assembly from the PHM Detach the four plastic clips a b c d on the processor carrier assembly from the four corners of the heatsink A B C D as shown below and lift off the processor carrier assembly...

Страница 26: ...the Carrier Assembly Unlock the lever from its locked position and push it upwards to disengage the processor from the carrier as shown below right Carefully remove the processor from the carrier Proc...

Страница 27: ...2 C1 D1 E1 E2 F1 F2 G1 H1 A1 A2 C1 C2 D1 D2 E1 E2 G1 G2 H1 H2 or A1 A2 B1 C1 C2 D1 E1 E2 F1 G1 G2 H1 16 DIMMs all MAC CODE BIOS LICENSE IPMI CODE BAR CODE 1 PRESS FIT 1 1 1 1 1 1 1 1 1 PRESS FIT PRESS...

Страница 28: ...oves memory performance Use memory modules of the same type and speed as mixing is not allowed Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different chan nels and across dif...

Страница 29: ...om the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Tabs 2 Al...

Страница 30: ...RAID configurations using a controller the meaning of the status indicator is described in the table below For OS RAID or non RAID configurations some LED indications are not supported such as hot sp...

Страница 31: ...g a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the chass...

Страница 32: ...rrier with the connector end toward the rear of the carrier 3 Tilt the drive to insert it onto the two posts on the right inside of the carrier 4 Pull out the two locking clasps seat the drive fully i...

Страница 33: ...IPMI Server Health NVMe SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by th...

Страница 34: ...e Temperature of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD Shows the temperatures of all NVMe drives IPMI Server Health Sensor Reading NVME_SSD...

Страница 35: ...SSD of length 42mm 60mm 80mm or 110mm The SBI 610P 1T2N model supports two additional M 2 NVMe SSDs of length 42mm 80mm or 110mm For each length there is a hole in the mounting platform for a plastic...

Страница 36: ...y standard anti static equipment such as gloves or wrist strap and follow precautions to avoid damage caused by ESD 1 Insert the SSD into the socket on the motherboard or bridge board Then push it fla...

Страница 37: ...ugh a hole in the bracket marked below as hidden 2 Insert the GPU PCIe contacts into the riser card slot while fitting the GPU into the assembly 3 Re install the assembly into the blade chassis 4 Conn...

Страница 38: ...s only non partitioned unformatted hard drives installed and no bootable devices attached to it Once these conditions are met make sure the PXE server is running Then turn on the blade on which you wi...

Страница 39: ...d Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive...

Страница 40: ...it may be installed to insure preservation of cache data in the event of a power outage Note SuperCap card must be installed on the AOM BPNIO SCE2 bridge card before the bridge card and the motherboar...

Страница 41: ...ing SuperCap 1 Mount the SuperCap card onto the bridge board using two screws and standoffs 2 Install the bridge board and motherboard 3 Mount two metal standoffs and one plastic standoff onto the bri...

Страница 42: ...acitor bracket with three screws as shown Ensure the plastic standoff is pushed into the bracket 5 Install SuperCap capacitor on the bracket 6 Connect the cable to the plug on the SuperCap card Use th...

Страница 43: ...ystem and perform management activities IPMI The SBI 610P 1 C T 2N blade supports the Intelligent Platform Management Interface IPMI IPMI provides remote access monitoring and management through the b...

Страница 44: ...SuperBlade Server SBI 610P 1 C T 2N User s Manual 44 Figure 3 2 Service Tag Location on Blade Module Service Tag...

Страница 45: ...gement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server yo...

Страница 46: ...rd Replacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out o...

Страница 47: ...nstalling the Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency Installing the Standard Air Shrouds Position the air shrouds as illustrated in the figure below sliding them over t...

Страница 48: ...gn objects obstruct air flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1...

Страница 49: ...number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when se...

Страница 50: ...MMC2 DIMMG1 DIMMH2 DIMMG2 DIMMH1 DIMME2 DIMME1 DIMMF2 DIMMF1 JRC1 SRW_1 SRW_4 SRW_2 SRW_3 JGPU1 JMEZZ1 J6 JKVM1 JPME1 JWD1 JPG1 J3 MH3 MH1 MH2 MH9 MH6 MH4 MH7 MH8 MH5 JPFR1 JADV1 JDBG1 JPFR3 JPFR2 PWR...

Страница 51: ...nnector J6 Front Storage Module Connector JGPU1 12V GPU Power Connector ATX 8 pin JKVM1 VGA USB Module Connector JMEZZ1 Mezzanine Card Slot JP1 JP2 PLD Header Manufacturing Use Only JRC1 Proprietary R...

Страница 52: ...RGB UART JKVM1 2 x USB 2 0 480 Mbps PCE0 32MB BIOS FLASH SPI 25 MHz DDR4 DDR4 256MB SPI 64MB BMC Flash SPI 25 MHz 480 Mbps 1 x USB 3 0 5 0 Gbps USB TYPE A 25 MHz PCE8 11 SATA5 8 0 GT s PCIe 3 0 x4 M 2...

Страница 53: ...s PCIe 3 0 x4 SSD in the form factors 2242 2260 2280 or 22110 Main Power Connector PWR1 and PWR2 are primary power supply connectors that provide power to the motherboard via the chassis backplane 12V...

Страница 54: ...or J6 is the front storage connector that connects to a SAS HBA RAID NVMe or M 2 device TPM Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from Sup...

Страница 55: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 56: ...ource for essential function use only without putting restrictions on power use In the single operation mode online upgrade will be available in Recovery mode ME Recovery Jumper Settings Jumper Settin...

Страница 57: ...57 Chapter 4 Motherboard Connections 4 4 LED Indicators BMC Heartbeat LED BMC_HB_LED1 is the BMC heartbeat LED When the LED is blinking green BMC is functioning normally...

Страница 58: ...blue When an option is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key...

Страница 59: ...key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as...

Страница 60: ...figuration INTEL SSDPERKX010T8 PHLJ00800K11P0I AVAGO MegaRAID AVAGO3108 MegaRAID Configuration Utility 03 25 05 12 VLAN Configuration MAC 3CECEF71D356 MAC 3CECEF71D356 IPv6 Network Configuration MAC 3...

Страница 61: ...Chapter 5 UEFI BIOS 61 Save Exit Save Options Default Options Boot Override...

Страница 62: ...ffset nnnn of the 64k block at which the error was detected System RAM Failed at offset nnnn System RAM failed at offset nnnn of in the 64k block at which the error was detected Extended RAM Failed at...

Страница 63: ...RAM cache failed and BIOS disabled the cache On older boards check the cache jumpers You may have to replace the cache See your dealer A disabled cache slows system performance considerably CPU ID CP...

Страница 64: ...s and display it on the screen If it cannot locate the address it displays Press F1 to resume F2 to Setup F3 for previous Displayed after any recoverable error message Press F1 to start the boot proce...

Страница 65: ...04h Get CPU type 06h Initialize system hardware 07h Disable shadow and execute code from the ROM 08h Initialize chipset with initial POST values 09h Set IN POST flag 0Ah Initialize CPU registers 0Bh E...

Страница 66: ...ix Dispatch Manager 36h Warm start shut down 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize...

Страница 67: ...s 67h Initialize Multi Processor APIC 68h Enable external and CPU caches 69h Setup System Management Mode SMM area 6Ah Display external L2 cache size 6Bh Load custom defaults optional 6Ch Display shad...

Страница 68: ...rmine number of ATA drives optional 90h Initialize hard disk controllers 91h Initialize local bus hard disk controllers 92h Jump to UserPatch2 93h Build MPTABLE for multi processor boards 95h Install...

Страница 69: ...y MultiBoot menu BEh Clear screen optional BFh Check virus and backup reminders C0h Try to boot with INT 19 C1h Initialize POST Error Manager PEM C2h Initialize error logging C3h Initialize error disp...

Страница 70: ...ize the CPU E3h Initialize system timer E4h Initialize system I O E5h Check force recovery boot E6h Checksum BIOS ROM E7h Go to BIOS E8h Set Huge Segment E9h Initialize Multi Processor EAh Initialize...

Страница 71: ...ing the address line or bits that failed For example 2C 0002 means address line 1 bit one set has failed 2E 1020 means data bits 12 and 5 bits 12 and 5 set have failed in the lower 16 bits The BIOS al...

Страница 72: ...ent for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 73: ...er equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a e...

Страница 74: ...t werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers...

Страница 75: ...de alimentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u...

Страница 76: ...rrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l...

Страница 77: ...entes de energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le sys...

Страница 78: ...rdelen dient u alle spanningsbronnen en alle stroomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be all...

Страница 79: ...ation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This warning does not apply to workstations Adv...

Страница 80: ...cceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L...

Страница 81: ...type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de maner...

Страница 82: ...ikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection...

Страница 83: ...at stroomloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexion...

Страница 84: ...ung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriq...

Страница 85: ...o debe cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigh...

Страница 86: ...ationale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled a...

Страница 87: ...t ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous...

Страница 88: ...los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soi...

Страница 89: ...zen von UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Super...

Страница 90: ...qu sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el produ...

Страница 91: ...chaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een...

Страница 92: ...el Rapid Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterpr...

Страница 93: ...ROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs AOC VROCPREMOD 951606 Int...

Страница 94: ...e Restrictions and Requirements section on a previous page 2 Reboot the server and press DEL key to enter BIOS 3 Switch to Advanced Chipset Configuration North Bridge IIO Configuration Intel VMD Techn...

Страница 95: ...g Intel VMD controller 6 Select the desired PCIe slot to Enable or Disable Intel VMD functionality according to the current hardware configuration being used Hot Plug Capability can also be Enabled or...

Страница 96: ...k on each CPU to be enabled or disabled In this example we enabled CPU1 Slot1 Figure C 5 and CPU2 Slot5 Figure C 6 our 4x U 2 form factor SSDs as well as CPU1 M 2 C 1 and CPU1 M2 C 2 our 2x M 2 form f...

Страница 97: ...el R Virtual RAID on CPU All Intel VMD Controllers Create RAID Volume 10 Set Name 11 Set RAID Level 12 If cross controller RAID is required select Enable RAID spanned over VMD Controller 13 Select spe...

Страница 98: ...move the device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s arti...

Страница 99: ...E CPU 25G P Chassis MCP 680 61005 0N 6U WxHxD 1 75 x 6 5 x 23 5 in 44 5 x 165 x 597 mm Storage Drives Two hot swap 2 5 hybrid bays for SBI 610P 1C2N NVMe SAS3 or SATA3 SBI 610P 1T2N NVMe or SATA3 M 2...

Страница 100: ...4 3 BS EN 61000 4 4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive Product Safety 2014 35 EU...

Отзывы: