SuperBlade Server SBA-4119S-(C/T)2N User's Manual

BIOS POST Messages

BIOS Message

Description

Previous boot incomplete - 

Default configuration used

Previous POST did not complete successfully. POST loads default values 

and offers to run Setup. If the failure was caused by incorrect values and 

they are not corrected, the next boot will likely fail. On systems with control of 

wait states, improper Setup settings can also terminate POST and cause this 

error on the next boot. Run Setup and verify that the waitstate configuration is 

correct. This error is cleared the next time the system is booted.

Memory Size found by POST 

differed from CMOS

Memory size found by POST differed from CMOS.

Diskette drive A error

Diskette drive B error

Drive A: or B: is present but fails the BIOS POST diskette tests. Check to see 

that the drive is defined with the proper diskette type in Setup and that the 

diskette drive is attached correctly.

Incorrect Drive A type - run 

SETUP

Type of floppy drive A: not correctly identified in Setup.

Incorrect Drive B type - run 

SETUP

Type of floppy drive B: not correctly identified in Setup.

System cache error - Cache 

disabled

RAM cache failed and BIOS disabled the cache. On older boards, check 

the cache jumpers. You may have to replace the cache. See your dealer. A 

disabled cache slows system performance considerably.

CPU ID:

CPU socket number for Multi-Processor error.

EISA CMOS not writeable

ServerBIOS2 test error: Cannot write to EISA CMOS.

DMA Test Failed

ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory 

Access) registers.

Software NMI Failed

ServerBIOS2 test error: Cannot generate software NMI (Non-Maskable 

Interrupt).

Fail-Safe Timer NMI Failed

ServerBIOS2 test error: Fail-Safe Timer takes too long.

device Address Conflict

Address conflict for specified device.

Allocation Error for: device

Run ISA or EISA Configuration Utility to resolve resource conflict for the 

specified device.

CD ROM Drive

CD ROM Drive identified.

Entering SETUP...

Starting Setup program

Failing Bits: nnnn

The hex number nnnn is a map of the bits at the RAM address which failed the 

memory test. Each 1 (one) in the map indicates a failed bit. See errors 230, 

231, or 232 above for offset address of the failure in System, Extended, or 

Shadow memory.

Fixed Disk n

Fixed disk n (0-3) identified.

Invalid System Configuration 

Data

Problem with NVRAM (CMOS) data.

I/O device IRQ conflict

I/O device IRQ conflict error.

PS/2 Mouse Boot Summary 

Screen:

PS/2 Mouse installed.

Содержание SuperBlade SBA-4119S-C2N

Страница 1: ...USER S MANUAL Revision 1 0 SuperBlade Server SBA 4119S C2N SBA 4119S T2N...

Страница 2: ...ipment is operated in an industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction man...

Страница 3: ...rs and utilities www supermicro com wftp driver AMD SP3 Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at s...

Страница 4: ...m the Enclosure 16 Removing or Replacing the Blade Cover 16 2 3 Powering Up or Down 17 Powering Up a Blade Unit 17 Powering Down a Blade Unit 17 2 4 Installing the Processor and Heatsink 18 2 5 Memory...

Страница 5: ...44 Overheating 44 3 5 Where to Get Replacement Components 45 3 6 Returning Merchandise for Service 45 Chapter 4 Motherboard Connections 4 1 Motherboard Layout 47 Quick Reference 48 4 2 Headers and Con...

Страница 6: ...m Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supe...

Страница 7: ...d features of the SBA 4119S C T 2N blade server It is based on the BH12SSi M25 motherboard Models System Storage Type Add on Module SBA 4119S T2N SATA NVMe hybrid ports AOM BPNIO SNEA P SBA 4119S C2N...

Страница 8: ...r website at Supermicro com Chipset System on Chip Memory Eight slots for up to 2 TB of 3DS RDIMM LRDIMM with speeds of up to 3200 MHz support for Non Volatile DIMM NVDIMM Storage Drives Two hot swap...

Страница 9: ...blinks until every node is ready Amber steady Power off 3 KVM UID LED Blue steady Indicates that KVM has been initialized Blue flashing slowly Unit IDentifier indicator The UID function is activated...

Страница 10: ...icators 2 Storage Drives Two hot swap 2 5 drive bays for NVME SAS or SATA the drive carriers display status lights 3 Service Asset Tag Pull out identifier with BMC ADMIN default password sticker 1 4 F...

Страница 11: ...11 Chapter 1 Introduction 1 5 Components Figure 1 4 Components Labeled see the next page 1 5 4 3 2...

Страница 12: ...User s Manual Blade Components Item Feature Description 1 Drives Two 2 5 storage drives 2 CPU Processor and heatsink 3 Memory DIMM slots under air shrouds 4 M 2 Slots Slots and standoffs for M 2 stora...

Страница 13: ...anine slot PCIE X16 G1 0 15 G2 18 15 CX4 25G LAN P0 P1 P2 P3 P0 0 3 P1 0 15 P2 0 15 M 2 PCIE X4 SATA M 2 PCIE X4 SATA P0 4 7 PCIE X16 PCIE cable connector PCIE X16 BMC AST2500 PHY RTL8211FS VGA CPU US...

Страница 14: ...ting systems may be mixed together in the same blade enclosure 2 1 Unpacking the System Inspect the box the system was shipped in and note if it was damaged in any way If any equipment appears damaged...

Страница 15: ...the blade unit is on before insertion Installing a Blade Unit into the Enclosure 1 Pull open the blade locking handle and slowly push the blade into its bay as pictured below 2 When the blade stops pu...

Страница 16: ...om the enclosure Removing or Replacing the Blade Cover The blade cover can be removed to access the mainboard and install processors memory modules the onboard battery etc To remove the cover after re...

Страница 17: ...he use of the onboard BMC chip in the blade module Powering Down a Blade Unit A blade unit may be powered down in any of the following ways Press the power button on the blade unit Use IPMIView or the...

Страница 18: ...h can damage components Assemble the processor CPU and heatsink together first then install that assembly onto the CPU socket Notes The motherboard should be installed into the chassis first and the p...

Страница 19: ...as described in Section 2 3 1 Use a Torx T20 driver to loosen the screws holding down Force Frame in the sequence of 3 2 1 The screws are numbered on the Force Frame next to each screw hole Tighten to...

Страница 20: ...il Frame up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the Rail Frame lift it to a position so you can do the next step of removing the External Cap...

Страница 21: ...ly from its shipping tray and while gripping the handle align the flanges of the Carrier Frame onto the rails of the Rail Frame so its pins will be at the bottom when the Rail Frame is lowered later 6...

Страница 22: ...lift tabs marked Remove at the middle of the cap and pull vertically upwards to remove the PnP Cover Cap Caution The exposed socket contacts are extremely vulnerable and can be damaged easily Do not t...

Страница 23: ...16 1 kgf cm 14 lbf in of torque The Force Frame secures both the Rail Frame and CPU Package Caution Tightening must be executed in proper 1 2 3 sequence to avoid causing catastrophic damage to the soc...

Страница 24: ...orx T20 driver in a diagonal pattern as below tighten the four heatsink screws halfway and then tighten them evenly to 16 1 kgf cm 14 0 lbf in of torque The processor and heatsink installation is comp...

Страница 25: ...w and remove the heatsink screws from the motherboard in the sequence as show in the figure above 2 Hold and gently pivot the heatsink back and forth to loosen it from the CPU Do not use excessive for...

Страница 26: ...RDIMM 1R 32GB 128GB 256GB 3200 2R 64GB 256GB 512GB 3200 LRDIMM 4R 128GB 512GB 1TB 3200 2S4R 256GB 1TB 2TB 3200 LRDIMM 3DS 2S2R 4 Ranks 128GB 512GB 1TB 3200 2S4R 8 Ranks 256GB 1TB 2TB 3200 DIMM Module...

Страница 27: ...mended 4 DIMMs 6 DIMMs Unbalanced not recommended 8 DIMMs J19 H12SSW iN MEGERAC LICENSE MAC CODE BAR CODE MH15 JF1 LED11 JWD1 JUART2 HDT1 JVRM1 JSLIM3 B1 JSLIM2 JSLIM1 FAN6 FAN5 FAN4 FAN3 FAN2 FAN1 JL...

Страница 28: ...power from the system as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release T...

Страница 29: ...D configurations using a controller the meaning of the status indicator is described in the table below For OS RAID or non RAID configurations some LED indications are not supported such as hot spare...

Страница 30: ...Removing a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of t...

Страница 31: ...ar of the carrier Align the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to the carrier w...

Страница 32: ...rive 1 IPMI Server Health NVMe SSD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorize...

Страница 33: ...an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD Shows the temperatures of all NVMe drives as in Figure 3 4 IPMI Server Health Sensor Reading NVME_SSD...

Страница 34: ...34 M 2 Solid State Drives Up to two M 2 solid state drives SSDs can be installed supporting PCIe Several lengths are supported 42mm 60mm 80mm or 110mm For each length there is an hole in the mounting...

Страница 35: ...se industry standard anti static equipment such as gloves or wrist strap and follow precautions to avoid damage caused by ESD 1 Insert the SSD into the socket on the riser card Then push it flat again...

Страница 36: ...anual 36 2 7 Installing the Mezzanine Card 1 Install the three standoffs as pictured below 2 Align the mezzanine card with the connector on the motherboard and slip it in 3 Secure it with three screws...

Страница 37: ...tual media at BMC console redirect with USB or ISO file to install Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and...

Страница 38: ...evices and finding none will connect to the PXE server to begin the boot install Installing by using Virtual Media Drive Redirection You can install the OS via Virtual Media through either the IPMIvie...

Страница 39: ...s on the system and perform management activities IPMI The SBA 4119S C T 2N blade supports the Intelligent Platform Management Interface IPMI IPMI provides remote access monitoring and management thro...

Страница 40: ...SuperBlade Server SBA 4119S C T 2N User s Manual 40 Figure 3 1 BMC Password Label Figure 3 2 Service Tag Location on Blade Module Service Tag...

Страница 41: ...nagement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server...

Страница 42: ...rd Replacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out o...

Страница 43: ...4 System Cooling Installing the Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency These do not require screws to install Installing the Air Shrouds Position the air shrouds as ill...

Страница 44: ...flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs display system heat status See Control Panel in Chapter 1 for details Overheating...

Страница 45: ...number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when se...

Страница 46: ...nnections are required Please review the Safety Precautions in Appendix B before installing or removing components Main Connectors A 2X PCIe Gen 4 x16 connector for MCIO cable B 2X M 2 Connector PCIe...

Страница 47: ...th jumper connector and LED locations shown See the table on the following page for descriptions 2X PCIe GEN 4 Connectors JPWR1 DIMMA1 IPMI LAN MB PWR JTPM1 JWD1 PWR LED JKVM1 JFP1 JPG1 JB1 JDBG1 DIMM...

Страница 48: ...utton IPMI LAN IPMI LAN connector JTPM1 Trusted Platform Module TPM Port 80 connector 2x PCIe x16 2x PCIe Gen 4 x16 connectors for MCIO cable 2x M 2 2x M 2 Connector PCIe Gen 4 x4 or 2X SATA support M...

Страница 49: ...rity device that supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the storage drive is not installed in the system For more inf...

Страница 50: ...ector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing th...

Страница 51: ...bled the user must write their own application software to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Default Pins 2 3 NMI Open Disabled Debug Mode Enable Disable JD...

Страница 52: ...the PWR LED is illuminated the system is turned on and all the system power rails are ready When the system is turned off or any one of the system power rails fails this LED will turn off Onboard Powe...

Страница 53: ...on is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of...

Страница 54: ...rd Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5...

Страница 55: ...tion HTTP BOOT Configuration Network Configuration iSCSI Configuration TLS Authenticate Configuration RAM Disk Configuration Avago MegaRAID Configuration Utility Driver Health IPMI Update IPMI LAN Con...

Страница 56: ...SuperBlade Server SBA 4119S C T 2N User s Manual 56 Save Exit Save Options Default Options Boot Override...

Страница 57: ...of the 64k block at which the error was detected System RAM Failed at offset nnnn System RAM failed at offset nnnn of in the 64k block at which the error was detected Extended RAM Failed at offset nnn...

Страница 58: ...he disabled RAM cache failed and BIOS disabled the cache On older boards check the cache jumpers You may have to replace the cache See your dealer A disabled cache slows system performance considerabl...

Страница 59: ...s it displays Press F1 to resume F2 to Setup F3 for previous Displayed after any recoverable error message Press F1 to start the boot process or F2 to enter Setup and change the settings Press F3 to d...

Страница 60: ...from the ROM 08h Initialize chipset with initial POST values 09h Set IN POST flag 0Ah Initialize CPU registers 0Bh Enable CPU cache 0Ch Initialize caches to initial POST values 0Eh Initialize I O comp...

Страница 61: ...3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot 42h Initialize interrupt vectors 45h POST device initializatio...

Страница 62: ...m Management Mode SMM area 6Ah Display external L2 cache size 6Bh Load custom defaults optional 6Ch Display shadow area message 6Eh Display possible high address for UMB recovery 70h Display error mes...

Страница 63: ...rs 92h Jump to UserPatch2 93h Build MPTABLE for multi processor boards 95h Install CD ROM for boot 96h Clear huge ES segment register 98h 1 2 Search for option ROMs One long two short beeps on check s...

Страница 64: ...ackup reminders C0h Try to boot with INT 19 C1h Initialize POST Error Manager PEM C2h Initialize error logging C3h Initialize error display function C4h Initialize system error handler C5h PnPnd dual...

Страница 65: ...Initialize the CPU E3h Initialize system timer E4h Initialize system I O E5h Check force recovery boot E6h Checksum BIOS ROM E7h Go to BIOS E8h Set Huge Segment E9h Initialize Multi Processor EAh Init...

Страница 66: ...12K RAM error it displays an additional word bitmap xxxx indicating the address line or bits that failed For example 2C 0002 means address line 1 bit one set has failed 2E 1020 means data bits 12 and...

Страница 67: ...ent for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 68: ...er equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a e...

Страница 69: ...t werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers...

Страница 70: ...de alimentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u...

Страница 71: ...rrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l...

Страница 72: ...entes de energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le sys...

Страница 73: ...roomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipme...

Страница 74: ...neel Attention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for instal...

Страница 75: ...cceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L...

Страница 76: ...type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de maner...

Страница 77: ...kant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection A...

Страница 78: ...at stroomloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexion...

Страница 79: ...ung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriq...

Страница 80: ...o debe cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigh...

Страница 81: ...ationale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled a...

Страница 82: ...t ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous...

Страница 83: ...los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soi...

Страница 84: ...zen von UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Super...

Страница 85: ...u sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el produc...

Страница 86: ...chaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een...

Отзывы: