22
SSG-2029P-ACR24H/L User's Manual
Warning:
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing. Failure to
stabilize the rack can cause the rack to tip over.
Figure 2-4. Extending and Releasing the Outer Rails
Note:
Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.
Installing the Outer Rails on the Rack
Installing the Outer Rails
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks of the front of the outer rail onto the slots on the front of the rack. If
necessary, use screws to secure the outer rails to the rack, as illustrated above.
4.
Pull out the rear of the outer rail, adjusting the length until it fits within the posts of the
rack.
5. Hang the hooks of the rear portion of the outer rail onto the slots on the rear of the
rack. If necessary, use screws to secure the rear of the outer rail to the rear of the rack.
6. Repeat steps 1-5 for the remaining outer rail.
21D01
L-min=676.00(26.61")(out
er rail)
1
3
4
2