Chapter 4: Basic Management Tasks
Configuring the Console Port
– 87 –
Figure 4-18: Setting the Time Zone
C
ONFIGURING
THE
C
ONSOLE
P
ORT
Use the System > Console menu to configure connection parameters for
the switch’s console port. You can access the onboard configuration
program by attaching a VT100 compatible device to the switch’s serial
console port. Management access through the console port is controlled by
various parameters, including a password (only configurable through the
CLI), time outs, and basic communication settings. Note that these
parameters can be configured via the web or CLI interface.
CLI R
EFERENCES
•
P
ARAMETERS
The following parameters are displayed:
•
Login Timeout
– Sets the interval that the system waits for a user to
log into the CLI. If a login attempt is not detected within the timeout
interval, the connection is terminated for the session.
(Range: 10-300 seconds; Default: 300 seconds)
•
Exec Timeout
– Sets the interval that the system waits until user input
is detected. If user input is not detected within the timeout interval, the
current session is terminated. (Range: 60-65535 seconds;
Default: 600 seconds)
•
Password Threshold
– Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a
specified amount of time (set by the Silent Time parameter) before
allowing the next logon attempt. (Range: 1-120; Default: 3 attempts)
•
Silent Time
– Sets the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 1-65535 seconds; Default: Disabled)
•
Data Bits
– Sets the number of data bits per character that are
interpreted and generated by the console port. If parity is being
generated, specify 7 data bits per character. If no parity is required,
specify 8 data bits per character. (Default: 8 bits)
Содержание SSE-G2252
Страница 42: ...44 General IP Routing on page 627...
Страница 174: ...Chapter 6 VLAN Configuration Configuring VLAN Mirroring 178 Figure 6 27 Showing the VLANs to Mirror...
Страница 511: ...Chapter 14 Basic Administration Protocols UDLD Configuration 518 Figure 14 100 Displaying UDLD Neighbor Information...
Страница 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Страница 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Страница 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Страница 1007: ...Chapter 33 Address Table Commands 1019...
Страница 1137: ...Chapter 38 Quality of Service Commands 1150...
Страница 1366: ...Chapter 46 IP Routing Commands Global Routing Configuration 1381 Connected 2 Total 2 FIB 0 Console...