Chapter 6: Rack Installation
Mid-Mount Telco Rack
The SC504 supports Telco Rack installation. The SC504 chassis compact design
allows the chassis to be installed into a Telco rack without the use of rails.
Installing the Chassis into a Telco (Two-Post Style) Rack:
To install the chassis into a Telco style two-post rack, use two L-shaped brackets
on either side of the chassis (four total). First, determine how far follow the server
will extend out the front of the rack. Larger chassis should be positioned to balance
the weight between front and back. If a bezel is included on your chassis, remove
it. Then attach the two front brackets to each side of the chassis, then the two
rear brackets positioned with just enough space to accommodate the width of the
Telco rack. Finish by sliding the chassis into the rack and tightening the brackets
to the rack.
Figure 6-2: Installing the Chassis into a Telco Rack
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Note: figures are for illustrative purposes only. Servers should always be
installed in racks from the bottom up.