2-15

Chapter 2: Standardized Warning Statements

경고 !

이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다 . 

Waarschuwing 

De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming 
met alle nationale wetten en reglementen.

Hot Swap Fan Warning

Warning!

The fans might still be turning when you remove the fan assembly from the 
chassis. Keep fingers, screwdrivers, and other objects away from the 

openings in the fan assembly's housing.

ファン・ホットスワップの警告

シャーシから冷却ファン装置を取り外した際、ファンがまだ回転している可能性があ
ります。

 ファンの開口部に、指、ドライバー、およびその他のものを近づけないで下

さい。

警告 !
警告!危险的可移动性零件。请务必与转动的风扇叶片保持距离。 当您从机架移除风扇装
置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他物品太靠近风扇
警告

危險的可移動性零件。請務必與轉動的風扇葉片保持距離。 當您從機架移除風扇裝置,

風扇可能仍在轉動。小心不要將手指、螺絲起子和其他物品太靠近風扇。

Warnung

Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis 
genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von 
den Öffnungen des Lüftergehäuses entfernt.

¡Advertencia! 

Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del 
chasis. Mandtenga los dedos, los destornilladores y todos los objetos lejos de las 
aberturas del ventilador

Содержание SBI-6419P-T3N

Страница 1: ...SBI 6419P T3N SuperBlade Module User s Manual Revison 1 0b...

Страница 2: ...venue for the resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and foun...

Страница 3: ...ter 3 Setup and Installation Refer to this chapter for details on installing the SBI 6419P T3N SuperBlade module into the SuperBlade chassis Other sections cover the installation and placement of memo...

Страница 4: ...ion 2 1 Installation Instructions 2 3 Circuit Breaker 2 4 Power Disconnection Warning 2 5 Equipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Vo...

Страница 5: ...rboard 3 12 3 4 Onboard Battery Installation 3 13 3 5 Memory Installation 3 13 Memory Support 3 13 Memory Population Guidelines 3 15 Memory Population Sequence 3 16 Installing Memory 3 16 ESD Precauti...

Страница 6: ...the Configuration Data 5 1 Starting the Setup Utility 5 1 5 2 BIOS Updates 5 2 5 3 Running Setup 5 2 5 4 Main BIOS Setup 5 3 5 5 Advanced Setup 5 5 5 6 Event Logs Setup 5 17 5 7 IPMI Setup 5 19 5 8 Se...

Страница 7: ...system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manua...

Страница 8: ...speed 8 GB 16 GB 32 GB 64 GB and 128 GB size memory per node Memory is interleaved which requires modules of the same size and speed to be installed in groups of two or three Table 1 1 SBI 6419P T3N...

Страница 9: ...ule For RAID setup see http www supermicro com support manuals under RAID Installation Guides for more details Enclosure Requirements The SBI 6419P T3N blade module requires one of the following enclo...

Страница 10: ...found on a sticker on the blade service tab and a sticker on the motherboard The sticker also displays the BMC MAC address For more information refer to our website at https www supermicro com en supp...

Страница 11: ...ess Supermicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Tech...

Страница 12: ...ssistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These wa...

Страница 13: ...ipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontr...

Страница 14: ...t u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE IN...

Страница 15: ...250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung...

Страница 16: ...ing Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system compon...

Страница 17: ...es les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me Waarschuwing Voordat u toegang nee...

Страница 18: ...nd de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hers...

Страница 19: ...ceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L a...

Страница 20: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne...

Страница 21: ...connection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle V...

Страница 22: ...ckplane when the system is operating Use caution when servicing Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung...

Страница 23: ...ud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Warnung Die Installation der Ger te muss den Sicherheitsst...

Страница 24: ...2 13 Chapter 2 Standardized Warning Statements...

Страница 25: ...ed according to all national laws and regulations Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este p...

Страница 26: ...Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten S...

Страница 27: ...assis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing Power Cable and AC Adapter Warning When installing the product use the pr...

Страница 28: ...s y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CS...

Страница 29: ...SBI 6419P T3N MicroBlade Module User s Manual 2 18 UL CSA Supermicro UL CSA...

Страница 30: ...de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet...

Страница 31: ...SBI 6419P T3N MicroBlade Module User s Manual 2 20...

Страница 32: ...blade unit node may be powered on and off independently from the rest of the blades and nodes installed in the same enclosure A blade unit may be powered up in two ways Press the power button on the...

Страница 33: ...ndle Note Blade Modules can be Hot Plugged from the enclosure Installing a Blade Unit into the Enclosure Installing a Blade Unit into the Enclosure 1 Slowly push the blade unit into its bay with the h...

Страница 34: ...3 3 Chapter 3 Setup and Installation Figure 3 1 Inserting a Blade into the Enclosure...

Страница 35: ...cord last and always remove it before adding removing or changing any hardware components Please note that the processor and heatsink should be assembled together first to form the Processor Heatsink...

Страница 36: ...sembly contains 1 the processor 2 the narrow processor clip 3 the dust cover and 4 the CPU socket Note Be sure to cover the CPU socket with the dust cover when the CPU is not installed 1 Processor 2 N...

Страница 37: ...ule User s Manual 3 6 Overview of the Processor Heatsink Module PHM The Processor Heatsink Module PHM contains 1 a heatsink 2 a narrow processor clip and 3 the processor 1 Heatsink 2 Narrow Processor...

Страница 38: ...insert the CPU into the processor clip by sliding notch B of the CPU into notch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the...

Страница 39: ...edge turn it upside down With the thermal grease side facing up locate the hollow triangle located at the corner of the processor carrier assembly a in the graphic Note a larger hole and plastic moun...

Страница 40: ...Processor Clip Upside Down C D d c a b A B On Locations of C D the notches snap onto the heat sink s mounting holes On Locations A B the notches snap onto the heatsink s sides A B D C Make sure Mounti...

Страница 41: ...and 4 a back plate These components are pre installed on the motherboard before shipping Removing the Dust Cover from the CPU Socket Remove the dust cover from the CPU socket exposing the socket and s...

Страница 42: ...p and you will see a triangle marked on the processor clip at the same corner of hollow triangle 2 Carefully align pin 1 the triangle on the the PHM against pin 1 the triangle on the CPU socket 3 Once...

Страница 43: ...from the socket starting with screw marked 4 in the sequence of 4 3 2 1 2 After all four screws are removed wiggle the PHM gently and pull it up to remove it from the socket Note To properly remove th...

Страница 44: ...down which reverses its polarities Figure 3 3 Installing the Onboard Battery 3 5 Memory Installation Memory Support The motherboard features twelve 12 288 pin DIMM sockets that can support up to 1 5 T...

Страница 45: ...ne Slot per Channel One DIMM per Channel 4 Gb 8 Gb 1 2 Volts RDIMM SRx4 8 GB 16 GB 2666 SRx8 4 GB 8 GB 2666 DRx8 8 GB 16 GB 2666 DRx4 16 GB 32 GB 2666 RDIMM 3Ds QRX4 N A 2H 64GB 2666 8RX4 N A 4H 128GB...

Страница 46: ...ith a pair of DIMM modules of the same type and size results in interleaved memory which improves memory performance Use memory modules of the same type and speed as mixing is not allowed x4 and x8 DI...

Страница 47: ...c discharge Handle the memory module by its edges only Put the memory modules into the antistatic bags when not in use Table 3 3 Memory Population 12 DIMM Slots DIMMs Memory Population Sequence 1 P1 D...

Страница 48: ...to the slot Caution Exercise extreme caution when installing or removing memory modules to prevent damage to the DIMMs or slots Removing Memory To remove a DIMM unlock the release tabs then pull the D...

Страница 49: ...to aid in correct installation 4 Secure the drive to the carrier with six screws as shown in Figure 3 4 5 Insert the drive carrier into its slot keeping the Open button at the bottom When the carrier...

Страница 50: ...to the PXE server to begin the boot install Installing via Virtual Media Drive Redirection You can install the OS via Virtual Media through either the IPMIview Java based client utility IPMItool or t...

Страница 51: ...SBI 6419P T3N SuperBlade Module User s Manual 3 20 For RAID setup see http www supermicro com support manuals under RAID Installation Guides for more details...

Страница 52: ...calable Socket P LGA 3647 Intel Xeon processor EP series processors per node Memory Supports up to 1 5 TB of RDIMM LRDIMM DDR4 2666 2400 MHz speed 8 GB 16 GB 32 GB 64 GB and 128 GB size memory in twel...

Страница 53: ...press and hold the power button for 4 seconds and the power LED will turn orange Table 4 2 Blade Control Panel Item Function State Description 1 Power Button N A Turns blade module on and off 2 Power...

Страница 54: ...it is a proprietary design which is based on the Intel C622 chipset See Figure 4 4 for a block diagram of this chipset and Figure 4 3 for a view of the SBI 6419P T3N module Figure 4 5 contains an expl...

Страница 55: ...CIe 3 0 x8 DDR4 CHC 2666 MHz DIMMA2 DIMMA1 DDR4 CHB 2666 MHz DDR4 CHA 2666 MHz IMC1 DIMMD2 2666 MHz DDR4 CHF DIMMD1 2666 MHz DDR4 CHE 2666 MHz DDR4 CHD LEWISBURG LGB 2 SATA3 SATA 3 0 6 0 Gbps SATA DOM...

Страница 56: ...OS pads with a metal object such as a small screwdriver 3 Replace the cover install the blade back into the enclosure and power it on Jumper Settings The following jumper settings can be used for the...

Страница 57: ...32 GB 64 GB and 128 GB size memory in twelve 12 288 pin DIMM sockets per node See Section 3 5 Memory Installation on page 3 13 for further details on mainboard memory installation Table 4 5 Main Comp...

Страница 58: ...ED See Chapter 1 for information on RAID Setup Additional drives can be added by a module card mounted in the front For RAID setup see http www supermicro com support manuals under RAID Installation G...

Страница 59: ...little electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is configu...

Страница 60: ...e in bold text unless otherwise noted The BIOS setup options described in this section are selected by choosing the appropriate text from the MAIN BIOS SETUP screen All displayed text is described in...

Страница 61: ...w keys to change the options for each setting Press the ESC key to exit the CMOS SETUP menu The next section describes in detail how to navigate through the menus Items that use sub menus are indicate...

Страница 62: ...ds and enter the correct data for the system date Press the Enter key to save the data System Time To set the system date and time key in the correct information in the appropriate fields Then press t...

Страница 63: ...w keys to display the ADVANCED SETUP menu The items with a triangle beside them are sub menus that can be accessed by highlighting the item and pressing ENTER Options for PIR settings are displayed by...

Страница 64: ...rusted Computing See Table 5 12 for a description of BIOS setup menu options in this sub menu Intel R Virtual RAID on CPU See Table 5 13 for a description of BIOS setup menu options in this sub menu T...

Страница 65: ...setting allows you to Enable or Disable the Adjacent Cache Prefetch DCU Streamer Prefetcher This setting allows you to Enable or Disable the DCU Streamer Prefetcher which is an L1 data cache prefetche...

Страница 66: ...to Enable or Disable Core C1E auto promotion control Note This setting only takes effect after a reboot Package C State Control Use this submenu to specify Package C State controls Package C State Th...

Страница 67: ...d for sparing tagging and leaky bucket Use the or keys on your numpad to toggle up or down a value or type in a number value for the field for this setting Default value is 10 SDDC This value Enables...

Страница 68: ...T for Directed I O VT d Use this submenu to bring up options for Intel VT for Directed I O configurations Intel VT for Directed I O VT d This setting allows you to Enable or Disable Intel Virtualizati...

Страница 69: ...support to your system Table 5 6 Server ME Information Sub menu Menu Option Description General ME Configuration Information General ME configuration information is displayed at the top of this scree...

Страница 70: ...automatically set the maximum Read Request size for a PCI E device to enhance system performance The options are Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes and 4096 Bytes MMCFG Base This...

Страница 71: ...s you to Enable or Disable Ipv6 PXE Support for your system If disabled the boot option for Ipv4 PXE Support will not be created Ipv6 HTTP Support This setting allows you to Enable or Disable Ipv6 HTT...

Страница 72: ...2 only This feature specifies the attribute of Serial Port 1 The options are SOL and COM Table 5 10 Serial Port Console Redirection Sub menu Menu Option Description COM1 Console Redirection COM2 SOL...

Страница 73: ...nabled Legacy OS Redirection Resolution Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This fe...

Страница 74: ...tings Sub menu Menu Option Description NUMA Use this setting to Enable or Disable NUMA WHEA Support This feature Enables the Windows Hardware Error Architecture WHEA support for the Windows 2008 or a...

Страница 75: ...R Virtual RAID on CPU Settings Sub menu Menu Option Description Use this menu if you have RAID volumes or Intel VMD Controllers on the system to configure your Intel Virtual RAID on CPU settings Other...

Страница 76: ...options are Do Nothing and Erase Immediately Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled The options are Disabled and Enabled MECI The Multiple Even...

Страница 77: ...5 19 Chapter 5 BIOS 5 7 IPMI Setup Figure 5 4 IPMI Setup Screen...

Страница 78: ...EL Use this setting for erasing the SEL Options are No Yes On Next Reset and Yes On Every Reset When SEL is Full Use this setting to choose options for reactions to a full SEL Options include Do Nothi...

Страница 79: ...istrator Password This allows you to create an administrator password for the system User Password This allows you to create user password for the system Password Check Use this setting to specify whe...

Страница 80: ...up Mode Options include Enabled and Disabled Install Factory Default Keys Use this setting to force the system to User Mode and install all factory default keys Pressing the Enter keyboard key will br...

Страница 81: ...MI BIOS Setup Utility main menu with the arrow keys to bring up the BOOT SETUP menu Security setting options are displayed by highlighting the setting using the arrow keys and pressing ENTER All Secur...

Страница 82: ...der Add New Driver Option Use this submenu to add a new EFI driver option to the driver order Add driver option Selecting this option brings up a field for entering a name for a new driver option Path...

Страница 83: ...oose SAVE EXIT from the 128 Mb SPI Flash EEPROM with AMI BIOS BIOS Setup Utility main menu with the arrow keys to display the SAVE EXIT SETUP menu All Exit BIOS settings are described in Table 5 18 be...

Страница 84: ...it ENTER to save changes done so far to any of the setup options Discard Changes Highlight this item and hit ENTER to discard cancel any changes you made You will remain in the Setup utility Restore O...

Страница 85: ...1 Click on the graphic in the SYSTEM SYSTEM INFORMATION screen to launch the KVM Console window as shown in Figure A 1 Alternately you may go to the CONFIGURATION CONSOLE REDIRECTION screen Figure A 2...

Страница 86: ...Manual A 2 2 In the KVM Console window click on the VIRTUAL STORAGE menu option from the VIRTUAL MEDIA menu Figure A 3 The VIRTUAL STORAGE window will be displayed Figure A 4 Figure A 3 KVM Console Wi...

Страница 87: ...ISO File from the LOGICAL DRIVE TYPE menu if you wish to mount an ISO file Figure A 5 Figure A 5 Selecting ISO File to Mount an ISO File 4 Browse for the ISO file on your local disk that contains the...

Страница 88: ...User s Manual A 4 5 After you have selected the ISO file press the Plug In button then the OK button to exit the VIRTUAL STORAGE window Figure A 7 Skip ahead to step 8 Figure A 7 Pressing the Plug In...

Страница 89: ...you wish instead to download the BIOS update from a USB Flash drive then insert the flash drive into your system and select it from the Logical Drive Type menu Figure A 8 Figure A 8 Selecting a USB Fl...

Страница 90: ...ser s Manual A 6 7 After you have selected the USB flash drive file press the Plug In button then the OK button to exit the VIRTUAL STORAGE window Figure A 9 Figure A 9 Pressing the Plug In and OK But...

Страница 91: ...e module by selecting the POWER CONTROL SET POWER RESET menu option from the KVM CONSOLE window If the MicroBlade is not powered on yet please select SET POWER ON from the menu Figure A 10 Figure A 10...

Страница 92: ...eyboard s F11 key in order to boot into the INVOKE BOOTABLE DEVICES LIST From this list select the ATEN Virtual CDROM YS0J command Your MicroBlade will now boot up into mounting the ISO file which con...

Страница 93: ...se the KVM CONSOLE window or go to the Virtual Storage window see step 2 and click on Plug Out this will remove mounting of the ISO file Figure A 12 Figure A 12 Clicking Plug Out in the Virtual Storag...

Страница 94: ...ted to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ul...

Отзывы: