PDSM4+/PDSME+ User's Manual
Rebuilding Arrays
Note 1:
Rebuilding applies to Fault Tolerant array (RAID 1) only.
If an array Build process is interrupted or when one critical member is missing,
you must perform a Rebuild to restore its functionality. For a critical array rebuild
operation, the optimal drive is the source drive.
Note 2:
If no spare array exists and a hard disk drive fails, you need to create a
spare before you can rebuild an array.
To Rebuild an array:
1
From the Main Menu, select
Manage Arrays
(as shown in the screen below).
From the List of Arrays, select the array you want to Rebuild.
2
Press <
Ctrl>
and
<R>
to Rebuild.