2.2 Motherboard Installation

All motherboards have standard mounting holes to fit different types of chassis. Make sure 
that the locations of all the mounting holes for both the motherboard and the chassis match. 
Although  a  chassis  may  have  both  plastic  and  metal  mounting  fasteners,  metal  ones  are 
highly recommended because they ground the motherboard to the chassis. Make sure that 
the metal standoffs click in or are screwed in tightly.

Phillips 

Screwdriver (1)

Standoffs (11)

Only if Needed

Phillips Screws

Tools Needed

Location of Mounting Holes

Notes:

 

1. 

To avoid damaging the motherboard and its components, please do not use a force 

greater than 8 lb/inch on each mounting screw during motherboard installation. 

2. 

Some components are very close to the mounting holes. Please take precautionary 

measures to avoid damaging these components when installing the motherboard to the 

chassis.

Содержание H12SSL Series

Страница 1: ...USER S MANUAL Revision 1 0a H12SSL i C CT NT...

Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...power Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor memory updates please refer to our website at http www supermicro com pr...

Страница 4: ...Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicr...

Страница 5: ...tal Temperature Control 17 System Resource Alert 17 1 5 ACPI Features 18 1 6 Power Supply 18 1 7 Super I O 18 Chapter 2 Installation 2 1 Static Sensitive Devices 19 Precautions 19 Unpacking 19 2 2 Mot...

Страница 6: ...pport Procedures 51 3 3 Frequently Asked Questions 51 3 4 Returning Merchandise for Service 53 3 5 Battery Removal and Installation 54 Battery Removal 54 Proper Battery Disposal 55 Battery Installatio...

Страница 7: ...Appendix B Standardized Warning Statements B 1 Battery Handling 95 B 2 Product Disposal 97 Appendix C UEFI BIOS Recovery C 1 Overview 98 C 2 Recovering the UEFI BIOS Image 98 C 3 Recovering the BIOS...

Страница 8: ...uct drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm A secure data deletion tool designed to fully erase all...

Страница 9: ...CT NT Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactly...

Страница 10: ...A2 3 JD1 JSTBY1 SGPIO1 JPS1 JOH1 JUID FAN1 JPI2C1 JPWR2 JPWR1 IPMI LAN USB2 3 LAN1 LAN2 VGA UID SW UID LED BT1 JPL1 JWD1 M 2 M2 M 2 M1 I SATA4 5 I SATA6 7 FAN4 FAN3 FANB FAN2 FANA SATA0 7 SGPIO2 PCIe...

Страница 11: ...izing LE1 Power OK LED Green System power OK LEDSAS SAS port active LED Green SAS port active H12SSL C H12SSL CT only Connector Description Battery BT1 Onboard CMOS battery JNCSI1 NCSI header COM 1 Re...

Страница 12: ...in CPU core power supply connector JD1 Front panel external speaker header JPI2C1 Power supply SMBus I2 C header LAN1 LAN2 Back panel LAN1 LAN2 connectors VGA Back panel VGA port Note Jumpers connecto...

Страница 13: ...M 2 Key M Key Network ATEN IPMI from ASPEED AST 2500 BMC for gigabit RJ45 port Dual RJ45 LAN ports H12SSL i C 1GbE Broadcom 5720L H12SSL CT NT 10GbE Broadcom 57416 Graphics ASPEED AST2500 BMC chip wit...

Страница 14: ...2V 3 3V Standby 5V Standby VBAT Memory Onboard monitoring for CPU system and memory temperature CPU switching phase voltage regulator CPU Thermal Trip support Fan Control Dual cooling zones Low noise...

Страница 15: ...Slot 3 PCIe x16 G0 0 15 G2 0 7 G2 8 11 SATA 0 7 or NVMe 0 1 G2 12 15 PCIe x4 M 2 PCIe x4 M 2 PCIe x8 Slot 2 G3 8 15 LSI 3008 Mini SAS HD Mini SAS HD NVMe 2 3 or SATA 8 15 G3 0 7 P0 P1 P2 P3 Slot 5 PC...

Страница 16: ...ic Support Rev 6 1 Adaptive Thermal Management Monitoring PCIe 4 0 SATA 3 0 w transfer rates of up to 6 Gb s System Management Bus SMBus Specification Version 2 0 1 3 Special Features This section des...

Страница 17: ...e cooling fans through the IPMI Web interface The chassis fans are controlled by Thermal Management Environmental Temperature Control The thermal control sensor monitors the CPU temperature in real ti...

Страница 18: ...is necessary for proper and reliable operation It is even more important for processors that have high CPU clock rates In areas where noisy power transmission is present you may choose to install a li...

Страница 19: ...its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when not i...

Страница 20: ...they ground the motherboard to the chassis Make sure that the metal standoffs click in or are screwed in tightly Phillips Screwdriver 1 Standoffs 11 Only if Needed Phillips Screws Tools Needed Locatio...

Страница 21: ...21 Chapter 2 Installation Figure 2 1 Motherboard Mounting Holes...

Страница 22: ...all standoffs in the chassis as needed 5 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 6 Using the Phillips screwdriver insert a Phillips head 6 scr...

Страница 23: ...all the CPU heatsink If you buy a CPU separately make sure that you use an AMD certified multi directional heatsink only Make sure to install the motherboard into the chassis before you install the CP...

Страница 24: ...stopping position 3 Lift the Rail Frame up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the Rail Frame lift it to a position so you can do the next st...

Страница 25: ...the handle of the Carrier Frame CPU Package assembly from its shipping tray and while gripping the handle align the flanges of the Carrier Frame onto the rails of the Rail Frame so its pins will be at...

Страница 26: ...gain and double check that the CPU is aligned properly 7 Lift up the Rail Frame till it securely rests in upright position Then remove the PnP Cover Cap from the CPU socket below Grip the two lift tab...

Страница 27: ...27 Chapter 2 Installation 8 Gently lower the Rail Frame down onto the socket until the latches on the Rail Frame engage with the Socket housing and it rests in place DO NOT force it into place...

Страница 28: ...spring loaded and has to be held in place before it is secured Important Use a torque screwdriver set it at 16 1 kgf cm 14 0 lbf in with a Torx T20 screw head bit to prevent damage to the CPU 10 Place...

Страница 29: ...k down till it rests securely over the four screw holes on CPU Package on the socket frame 12 Using a diagonal pattern tighten the four screws down on the heatsink in a clockwise fashion till it is se...

Страница 30: ...ail Frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the Carrier Frame and pull upwards to extract it from the Rail Frame Return the Carrier Frame CPU P...

Страница 31: ...Modules with AMD EPYC 7002 700 Processors Type DIMM Population Maximum DIMM Capacity GB Maximum Frequency MHz DIMM1 1 Channel 8 Channel RDIMM 1R 32GB 256GB 3200 2R or 2DR 64GB 512GB 3200 LRDIMM 3DS 2S...

Страница 32: ...modules of the same type size and speed should be installed Mixed DIMM speeds can be installed However all DIMMs will run at the speed of the slowest DIMM The motherboard will support odd numbered mod...

Страница 33: ...4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Press the notches on both ends of the module straight down into the slot until the module snaps i...

Страница 34: ...descriptions of the various I O ports on the rear of the motherboard Figure 2 1 I O Port Locations and Definitions Rear I O Ports Description Description Description 1 COM Port 4 USB 1 3 0 7 LAN Port...

Страница 35: ...ED indicators The UID Indicator provides easy identification of a system that may be in need of service Note UID can also be triggered via IPMI on the serverboard For more information on IPMI please r...

Страница 36: ...the front of the chassis These connectors are designed specifically for use with Supermicro chassis See the figure below for the location of JF1 Power Button UID LED 1 NIC1 Link LED Reset Button 2 HD...

Страница 37: ...sk On Module Power Connector JSD1 JSD2 The Disk On Module DOM power connector at JSD1 provides 5V power to a solid state DOM storage device connected to one of the SATA ports See the table below for p...

Страница 38: ...e one for each connector that supports up to four drives each SATA SAS Connectors Pin Definitions Pin Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground NVM Express Connecti...

Страница 39: ...hird party vendor A TPM is a security device that supports encryption and authentication in hard drives It enables the motherboard to deny access if the TPM associated with the hard drive is not insta...

Страница 40: ...tions Pin Definition Pin Definition 1 VBUS 19 Power 2 Stda_SSRX 18 USB3_RN 3 Stda_SSRX 17 USB3_RP 4 GND 16 GNd 5 Stda_SSTX 15 USB3_TN 6 Stda_SSTX 14 USB3_TP 7 GND 13 GND 8 D 12 USB_N 9 D 11 USB_P 10 x...

Страница 41: ...onboard battery provides backup power to the on chip CMOS which stores the BIOS setup information It also provides power to the Real Time Clock RTC to keep it running NCSI Header JNCSI1 The NCSI Netw...

Страница 42: ...ere to use the IPMB I2 C connection on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Main Power Supply Connector JPWR3 The primary power supply connect...

Страница 43: ...pin ATX power input to provide core power to the processor Refer to the table below for pin definitions 12V 8 pin Power Connector Pin Definitions Pins Definition 1 through 4 Ground 5 through 8 12V 12...

Страница 44: ...Connector Pins Jumper Setting 3 2 1 3 2 1 Clear CMOS JBT1 JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally c...

Страница 45: ...their own application software to disable it Watch Dog Jumper Settings Jumper Setting Definition Pins 1 2 Reset Default Pins 2 3 NMI Open Disabled VGA Enable Disable JPG1 JPG1 allows you to enable or...

Страница 46: ...Refer to the tables below for more information Link LED Connection Link Speed Indicator LED Color Definition Orange 1 Gb s Green 10 Gb s Activity LED Color State Definition None No Connection None Off...

Страница 47: ...LEDM1 is blinking the BMC is functioning normally See the table below for more information BMC Heartbeat LED State Color State Definition Green Solid On BMC is not ready Green Blinking BMC Normal Gre...

Страница 48: ...short circuits exist between the motherboard and chassis 4 Disconnect all cables from the motherboard including those for the keyboard and mouse 5 Remove all add on cards 6 Install a CPU a heatsink an...

Страница 49: ...led If the system boots check for bad DIMM modules or slots by following the Memory Errors Troubleshooting procedure in this chapter Memory Errors 1 Make sure that the DIMM modules are properly and fu...

Страница 50: ...website for more information on the minimum power requirements 6 Proper software support Make sure that the correct drivers are used B If the system becomes unstable before or during OS installation...

Страница 51: ...mation when contacting us for technical support Motherboard model and PCB revision number BIOS release date version this can be seen on the initial display when your system first boots up System confi...

Страница 52: ...s during memory count the first screen that appears when the system is turned on the momentary on off switch must be held for more than four seconds to shutdown the system This feature is required to...

Страница 53: ...by calling your vendor for a Returned Merchandise Authorization RMA number When returning to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and...

Страница 54: ...below 1 Power off your system and unplug your power cable 2 Locate the onboard battery as shown below 3 Using a tool such as a pen or a small screwdriver push the battery lock outwards to unlock it On...

Страница 55: ...waste management agency to dispose of your used battery properly Battery Installation 1 To install an onboard battery follow the steps 1 2 above and continue below 2 Identify the battery s polarity T...

Страница 56: ...en other keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured...

Страница 57: ...e Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between f...

Страница 58: ...m displays the date when the version of the BIOS ROM used in the system was built CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Memory Th...

Страница 59: ...ubmenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to...

Страница 60: ...tically reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog...

Страница 61: ...Fixed PSP Recovery BL Ver SMU FW Version ABL Version PSP Directory Level 2 Updateable PSP Bootloader Version SMU FW Version ABL Version ACPI Settings PCI AER Support The options are Disabled and Enabl...

Страница 62: ...l port specified by the user Select Auto to allow the BIOS to automatically assign the base I O and IRQ address The options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Страница 63: ...the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per secon...

Страница 64: ...solution support The options are Disabled and Enabled Legacy OS Console Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The opti...

Страница 65: ...ssion size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and...

Страница 66: ...designed for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy Console Redirection after BIOS POST When se...

Страница 67: ...is item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to...

Страница 68: ...sets the number of CCDs to be used The options include Auto 2 CCDs 3 CCDs 4 CCDs and 6 CCDs Core Control This sets the number of cores to be used by your system Once this option has been used to remov...

Страница 69: ...figuration Determinism Control Use this setting to configure the Determinism Slider Options include Manual and Auto cTDP Control Use this setting to configure the cTDP Control Options include Manual a...

Страница 70: ...ve memory blocks across the DRAM chip for node 0 The options are Disabled and Auto BankGroupSwap This setting controls the Bank Group Swap The options are Enabled Disabled and Auto DRAM Scrub Time Thi...

Страница 71: ...support or the device vendor defined firmware support The options are Vendor Defined Firmware and AMI Native Support M 2 AHCI Firmware Source Use this setting to select between the AMI Native firmware...

Страница 72: ...OM Use this setting to select which option ROM is to be loaded for onboard LAN1 on the system The options include Disabled Legacy and EFI Onboard LAN2 Option ROM Use this setting to select which firmw...

Страница 73: ...A 0 7 This setting selects NVMe or SATA engine for the hybrid port When Auto is selected JCFG1 2 jumper determines the behavior for JNVMe0 1 The options are Auto NVME and SATA JNVMe1 SATA 8 15 This se...

Страница 74: ...only The options are Enabled Disabled and Auto XHCI Hand Off This is a work around solution for operating systems that do not support XHCI Extensible Host Controller Interface hand off The XHCI owners...

Страница 75: ...tions are Updare Delte and Export HTTP Boot Configuration HTTP Boot One Time When the HTTP boot option is created this option when enabled will allow the system to boot via HTTP the first time and rev...

Страница 76: ...abled the following items will become available for configuration Local IP Address This item sets and displays the Local IP address for this computer This should be in decimal and in dotted quad form...

Страница 77: ...on Enroll Certification using File Use this feature to enroll certification from a file Certification GUID Use this feature to input the certification GUID Commit Changes and Exit Use this feature to...

Страница 78: ...orm Management Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI STATUS This item indicates the status of the IPMI firmware installe...

Страница 79: ...onfiguration IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is...

Страница 80: ...rt This section displays configuration features for IPv6 support IPv6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled If the item above is set to Enabled the follo...

Страница 81: ...BIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing Settings Erase Event Log Select Yes to erase all err...

Страница 82: ...ed MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item...

Страница 83: ...te a new or change an existing Administrator password Note that if the Administrator Password is erased the User Password will be cleared as well Password Check Select Setup for the system to check fo...

Страница 84: ...or Keys Provision Factory Defaults This feature is to provision the default secure boot keys set by the manufacturer when system is in the Setup mode The options are Disabled and Enabled Restore Facto...

Страница 85: ...re Boot keys set by the manufacturer The options are Disabled and Enabled Key Exchange Keys Set New Key Select Yes to load the KEK from the manufacturer s defaults Select No to load the KEK from a fil...

Страница 86: ...dd the DBT from the manufacturer s defaults list to the existing DBT Select No to load the DBT from a file The options are Yes and No OsRecovery Signature This item uploads and installs an OSRecovery...

Страница 87: ...tting is DUAL LEGACY to EFI Support This option Disables or Enables the system to boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities This option prioritizes...

Страница 88: ...ystem will boot during startup The settings are any pre defined boot device UEFI Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Order...

Страница 89: ...making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset...

Страница 90: ...ximum performance Save as User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use R...

Страница 91: ...supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive...

Страница 92: ...the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose...

Страница 93: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...

Страница 94: ...trol power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your ope...

Страница 95: ...nstalling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm B 1 Battery Handling Warnung Bei Einsetzen einer fa...

Страница 96: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 97: ...entos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp te...

Страница 98: ...ain BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is cor...

Страница 99: ...y process DO NOT INTERRUPT THIS PROCESS UNTIL IT IS FINISHED Note If you cannot locate the Super ROM file in your driver disk visit our website at www supermicro com to download the BIOS image into a...

Страница 100: ...ebGUI or SUM Please refer to these SUPERMICRO software related videos Activate OOB license https www youtube com watch v V4spX_DOV7I SUPERMICO BIOS Update https www youtube com watch v S8z6iOEHGwY If...

Отзывы: