USER’S MANUAL 

Revision 1.0

H12DGO-6

Содержание H12DGO-6

Страница 1: ...USER S MANUAL Revision 1 0 H12DGO 6...

Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...ce while consuming little power Please note that this motherboard is intended to be installed and serviced by professional technicians only For processor memory updates please refer to our website at...

Страница 4: ...uter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma s...

Страница 5: ...vironmental Temperature Control 17 System Resource Alert 17 1 5 ACPI Features 18 1 6 Power Supply 18 1 7 Super I O 18 Chapter 2 Installation 2 1 Static Sensitive Devices 19 Precautions 19 Unpacking 19...

Страница 6: ...3 Frequently Asked Questions 43 3 4 Returning Merchandise for Service 47 3 5 Battery Removal and Installation 47 Battery Removal 47 Proper Battery Disposal 47 Battery Installation 48 Chapter 4 UEFI BI...

Страница 7: ...ardized Warning Statements B 1 Battery Handling 90 B 2 Product Disposal 92 Appendix C UEFI BIOS Recovery C 1 Overview 93 C 2 Recovering the UEFI BIOS Image 93 C 3 Recovering the BIOS Block with a USB...

Страница 8: ...ivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product safe...

Страница 9: ...herboard Image Note All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual The motherboard you received may or may not look exactl...

Страница 10: ...10 H12DGO 6 User s Manual Note Components not documented are for internal testing only Figure 1 2 H12DGO 6 Motherboard Layout 4 3 C A REV 1 01 H12DGO 6 DESIGNED IN USA BAR CODE IPMI CODE...

Страница 11: ...rs not indicated are used for testing only Use only the correct type of onboard CMOS battery as specified by the manufacturer Do not install the onboard battery upside down to avoid possible explosion...

Страница 12: ...ro Advanced I O Module AIOM Slot via AOM 438G AIOM JMB_E1 JMB_E4 PCIe Connectors Connect to Middle Plate BPN GPU 438G JMB_E5 JMB_E6 Power Connectors Connect to Middle Plate BPN GPU 438G M 2 C1 M 2 C2...

Страница 13: ...x16 slot with PCIe x16 signal and 1 PCIe x16 slot with PCIe x8 signal 64 lane PCIe 4 0 connected to Middle Plate and Switch Boards to support GPU board and provide extra PCIe x16 slots Graphics ASPEED...

Страница 14: ...Width Modulation PWM fan control System Management Trusted Platform Module TPM support System resource alert via SuperDoctor 5 Power Supply Monitoring SuperDoctor 5 Watch Dog NMI SPM SUM InBand SUM O...

Страница 15: ...troduction Figure 1 3 System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the previous pages for the actual specifications of y...

Страница 16: ...ower Management Logic Support Rev 6 2 Adaptive Thermal Management Monitoring PCIe 4 0 w transfer rate of up to 16 0 GT s System Management Bus SMBus Specification Version 3 1 1 1 3 Special Features Th...

Страница 17: ...cooling fans The onboard CPU and chassis fans are controlled by Thermal Management Environmental Temperature Control The thermal control sensor monitors the CPU temperature in real time and will turn...

Страница 18: ...from noise It is recommended that you also install a power surge protector to help avoid problems caused by power surges 1 7 Super I O The Super I O Aspeed AST2600 chip includes a data separator write...

Страница 19: ...its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antistatic bags when not i...

Страница 20: ...ground the motherboard to the chassis Make sure that the metal standoffs click in or are screwed in tightly Philips Screwdriver 1 Standoffs 13 Only if Needed Philips Screws 13 Tools Needed Location o...

Страница 21: ...21 Chapter 2 Installation Figure 2 1 Motherboard Mounting Holes...

Страница 22: ...d against the mounting holes on the chassis 3 Install standoffs in the chassis as needed 4 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 5 Using the...

Страница 23: ...all the CPU heatsink If you buy a CPU separately make sure that you use an AMD certified multi directional heatsink only Make sure to install the motherboard into the chassis before you install the CP...

Страница 24: ...ping position 3 Lift the Rail Frame up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the Rail Frame lift it to a position so you can do the next step of...

Страница 25: ...the handle of the Carrier Frame CPU Package assembly from its shipping tray and while gripping the handle align the flanges of the Carrier Frame onto the rails of the Rail Frame so its pins will be at...

Страница 26: ...uble check that the CPU is aligned properly 8 Lift up the Rail Frame till it securely rests in upright position Then remove the PnP Cover Cap from the CPU socket below Grip the two lift tabs marked Re...

Страница 27: ...27 Chapter 2 Installation 9 Gently lower the Rail Frame down onto the socket until the latches on the Rail Frame engage with the Socket housing and it rests in place DO NOT force it into place...

Страница 28: ...ing loaded and has to be held in place before it is secured Important Use a torque screwdriver set it at 16 1 kgf cm 14 0 lbf in with a Torx T20 screw head bit to prevent damage to the CPU 11 Place an...

Страница 29: ...er the four screw holes on CPU Package on the socket frame 13 Using a diagonal pattern tighten the four screws down on the heatsink in a clockwise fashion till it is secure The heatsink will now be se...

Страница 30: ...Frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the Carrier Frame and pull upwards to extract it from the Rail Frame Return the Carrier Frame CPU Packa...

Страница 31: ...F2 G1 G2 H1 H2 16 DIMMS CPU1 A2 B2 C2 D2 E2 F2 G2 H2 CPU2 A2 B2 C2 D2 E2 F2 G2 H2 32 DIMMS CPU1 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 CPU2 A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 Pop...

Страница 32: ...lled However all DIMMs will run at the speed of the slowest DIMM The motherboard will support odd numbered modules 1 or 3 modules installed However to achieve the best memory performance fully populat...

Страница 33: ...ck it 3 Align the key of the DIMM module with the receptive point on the memory slot 4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Press both en...

Страница 34: ...other TPM pdf Trusted Platform Module Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 5 LRESET 6 NC 7 LAD3 8 LAD2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 NC 14 NC 15 3 3V_STBY 1...

Страница 35: ...ives Fan Headers There are eight fan headers on the motherboard These are 4 pin fan headers pins 1 3 are backward compatible with traditional 3 pin fans The onboard fan speeds are controlled by Fan Mo...

Страница 36: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...

Страница 37: ...the system if an application hangs Jumping pins 2 3 will generate a non maskable interrupt NMI signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Rese...

Страница 38: ...atus is ok Turn off the system and unplug the power cord before removing or installing components Front Power LED Indicator LED Color Definition Off System Off power cable not connected Green System O...

Страница 39: ...onnected to your power supply 4 Make sure that no short circuits exist between the motherboard and chassis 5 Disconnect all cables from the motherboard including those for the keyboard and mouse 6 Rem...

Страница 40: ...gging the power cord and contacting both pads on the CMOS Clear Jumper JBT1 Refer to chapter 2 2 Remove all components from the motherboard especially the DIMM modules 3 Turn on the system with only o...

Страница 41: ...t Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Check the system cooling to make sure that all heatsink fans and CPU system fans etc work...

Страница 42: ...se take the following steps Also note that as a motherboard manufacturer we do not sell directly to end users so it is best to first check with your distributor or reseller for troubleshooting service...

Страница 43: ...than your BIOS before downloading You can choose from the zip file and the exe file If you choose the zip BIOS file please unzip the BIOS file onto a bootable USB device Run the batch file using the...

Страница 44: ...IOMMU Change from Auto to Disabled Microsoft KB 4022723 Enabled machines with AMD I O Virtualization Technology IOMMU to boot without BIOS restriction https support microsoft com en us help 4022723 w...

Страница 45: ...ver 2019 is up to date 5 Ensure patch KB4512534 is now installed reboot the system and anter the BIOS setup utility 6 Set the option of Local APIC Mode to be x2APIC in BIOS BIOS Advanced CPU Configura...

Страница 46: ...s To solve this problem click OK and save the installation package to the location you specify The driver is then installed automatically Question When I ran the executable file setup exe to install t...

Страница 47: ...ed in shipping or from failure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems 3 5 Battery Rem...

Страница 48: ...ve and continue below 2 Identify the battery s polarity The positive side should be facing up 3 Insert the battery into the battery holder and push it down until you hear a click to ensure that the ba...

Страница 49: ...F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be conf...

Страница 50: ...date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day...

Страница 51: ...e version of the BIOS ROM used in the system was built CPLD Version This feature displays the version of the CPLD Complex Programmable Logical Device used in the system Memory Information Total Memory...

Страница 52: ...this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the norm...

Страница 53: ...ly reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer...

Страница 54: ...Level 1 Fixed PSP Recovery BL Ver SMU FW Version ABL Version PSP Directory Level 2 Updateable PSP Bootloader Version SMU FW Version ABL Version ACPI Settings PCI AER Support The options are Disabled...

Страница 55: ...the BIOS to automatically assign the base I O and IRQ address The options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and...

Страница 56: ...sion speed for a serial port used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy...

Страница 57: ...d on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled...

Страница 58: ...red for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and...

Страница 59: ...Disabled and Enabled Legacy OS Redirection Resolution For Legacy OS systems use this setting to specify the number of Rows and Columns supported for redirection Options include 80x24 and 80x25 Putty K...

Страница 60: ...nicate with a remote host server The options are COM1 and SOL Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII characte...

Страница 61: ...a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard seria...

Страница 62: ...ns are Disabled Enabled and Auto SVM Mode This setting Enables or Disables CPU Virtualization SMEE This setting Enables or Disables secure memory encryption CPU1 CPU2 Information These sections are fo...

Страница 63: ...figuration Memory Clock This setting allows you to select different memory clock speed The options include Auto and speed settings from 2666MHz 2933MHz to 3200MHz Memory Interleaving This setting cont...

Страница 64: ...These sections are for informational purposes They will display some details about the detected memory according to each CPU on the motherboard such as Detected Size per slot in MB Current Speed MT s...

Страница 65: ...e or Auto control the Alternative Routing ID Interpretation PCIe Spread Spectrum Use this setting to Disable or Enable PCIe Spread Spectrum for your system Relaxed Ordering Select Enabled to allow cer...

Страница 66: ...tem Options include Disabled and PXE Onboard NVMe1 Option ROM Select EFI to allow the user to boot the computer using an EFI Extensible Firmware Interface device installed on the NVME connector specif...

Страница 67: ...NVME connector specified by the user Select Legacy to allow the user to boot the computer using a legacy device installed on the NVME connector specified by the user The options include Disabled Legac...

Страница 68: ...port 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devices The options include Disabled and Enabled...

Страница 69: ...P address KMIP TCP Port number TimeZone Clinet UserName Client Password CA Certificate The options include Update Delete and Export Client Certificate The options include Update Delete and Export Clie...

Страница 70: ...xt available IP address for this computer The options include Disabled and Enabled If the item above is set to Disabled the following items will become available for configuration Local IP Address Thi...

Страница 71: ...led and Enabled Remove VLAN Click this option to remove an existing VLAN MAC AC1F6BBB6FB1 IPv4 Network Configuration Confiured The opitons include Disabled and Enabled If the item above is set to Enab...

Страница 72: ...5 Local Gateway This item sets the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 172 31 0 1 Local DNS Servers This item sets the address for the local DNS...

Страница 73: ...Chapter 4 UEFI BIOS 73 Save Changes and Exit Use this item to save the changes above and exit...

Страница 74: ...ootup The options include Disabled and Enabled Erashing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system...

Страница 75: ...m will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you will need...

Страница 76: ...ve made a change on a setting below please be sure to reboot the system for the change to take effect Change SMBIOS Event Log Settings Enabling Disabling Options SMBIOS Event Log Select Enabled to en...

Страница 77: ...tem to do nothing when the SMBIOS event log is full The options are Do Nothing and Erase Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events T...

Страница 78: ...e BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup for the system to check for a password at Setup Select Always for the syst...

Страница 79: ...nagement Provision Factory Defaults The options are Disabled and Enabled Restore Factory Keys Select Yes to restore manufacturer default keys used to ensure system security The options are Yes and No...

Страница 80: ...configure a set of values to be used as Key Exchange Keys for the system The sizes keys numbers and key sources of the Key Exchange Keys will be indicated as well Select Update to update your Key Exc...

Страница 81: ...ed signatures which will indicate the time when these signatures are entered into the system Select Update to update your Authorized TimeStamps Select Append to append your Authorized TimeStamps The s...

Страница 82: ...EGACY to EFI Support Select Enabled for the system to boot from an EFI OS when the Legacy OS fails The options are Disabled and Enabled FIXED BOOT ORDER Priorities This feature prioritizes the order o...

Страница 83: ...to select a boot device to delete from the boot priority list Delete Boot Option Use this feature to remove an EFI boot option from the boot priority list UEFI Application Boot Priorities Use this fea...

Страница 84: ...rmanent changes to the system configuration and reboot the computer Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility a...

Страница 85: ...elect Save as User Defaults from the Exit menu and press Enter This enables the user to save all changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User...

Страница 86: ...w supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash driv...

Страница 87: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the...

Страница 88: ...d Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive...

Страница 89: ...reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The defau...

Страница 90: ...alling or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm B 1 Battery Handling Warnung Bei Einsetzen einer falsc...

Страница 91: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 92: ...s nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent W...

Страница 93: ...control to a computer system at bootup C 2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains crit...

Страница 94: ...nto a USB flash device and rename it SUPER ROM 1 While the system is turned off insert the USB device that contains the new BIOS binary image SUPER ROM 2 Power on the system 3 After the system is turn...

Страница 95: ...or SUM Please refer to these SUPERMICRO software related videos Activate OOB license https www youtube com watch v V4spX_DOV7I SUPERMICO BIOS Update https www youtube com watch v S8z6iOEHGwY If the BI...