Chapter 1: Introduction
Quick Reference Table
Jumper
Description
Default Setting
UID SW
Unit ID switch (push-button toggle switch ON/OFF)
Off
JBT1
Clear CMOS
Open (Normal)
JPB1
BMC Enable/Disable
Pins 1-2: (Enabled)
JPG1
VGA Enable/Disable
Pins 1-2 (Enabled)
JDBG1
Debug mode control
Pins 1-2: Normal mode
JWD1
Watch Dog control
Pins 1-2 (Reset)
LED
Description
Status
UID LED1
Rear unit ID LED
Solid blue: UID switched to ON, unit identified
BMC_HB LED2
BMC Heartbeat LED
Green: Blinking (BMC normal), Green: Fast blinking (BMC initializing)
PWR_OK LED3
Power OK LED
Green: System power OK
Connector
Description
Battery (BT1)
Onboard CMOS battery
COM 1
Front panel COM port #1
FAN 3/4
System cooling fan headers
IPMI_LAN
Dedicated IPMI LAN port
JF1
Front control panel
JF2
PCI-E 3.0 x4 slot supported by CPU2
JSD1
SATA DOM power connector
JSDCARD1
Micro SD Card slot
JTPM1
Trusted Platform Module (TPM)/Port 80 connector
SIOM
PCI-E 3.0 x16 slot for proprietary add-on module supported by CPU1
SXB1
PCI-E 3.0 x4 slot supported by CPU2 and SATA connections (SATA0~5) by CPU1
SXB2
PCI-E 3.0 x24 slot supported by CPU2
SXB3
PCI-E 3.0 x16 left hand riser slot supported by CPU1
SXB4
PCI-E 3.0 x16 right hand riser slot supported by CPU1
SATA6
SATA DOM with power-pin connector
J2
M.2 connector PCI-E 3.0 x4 supported by CPU1 and SATA7 connection
USB 0/1 (3.0)
Back panel USB 3.0 ports
USB3 (2.0)
Internal USB 2.0 port
VGA
Back panel VGA port
Note:
Jumpers, connectors, switches, and LED indicators that are not described in the
preceding tables are for manufacturing testing purposes only, and are not covered in this
manual.