USER’S MANUAL
Revision 1.0a
FatTwin
®
AS -F2014S-RNTR
Страница 1: ...USER S MANUAL Revision 1 0a FatTwin AS F2014S RNTR...
Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...
Страница 3: ...rt manuals Product drivers and utilities https www supermicro com wdl Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our sup...
Страница 4: ...le 15 Chapter 2 Server Installation 2 1 Overview 17 2 2 Preparing for Setup 17 Choosing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating...
Страница 5: ...DIMM Installation 36 DIMM Removal 36 Motherboard Battery 37 3 5 System Nodes 38 Installing and Removing Hard Drives 38 Removing and Installing the Backplane 40 Removing the Backplane 40 Installing th...
Страница 6: ...2 BMC ADMIN User Password 62 Chapter 6 UEFI BIOS 6 1 Introduction 63 Starting the Setup Utility 63 6 2 Main Setup 64 6 3 Advanced 66 6 4 IPMI 86 6 5 Event Logs 89 6 6 Security 91 6 7 Boot 93 6 8 Save...
Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...
Страница 8: ...e for storage devices 2 port BPN SAS3 F424 A2N2A 4 Hybrid backplane for storage devices 6 port BPN SAS3 F424 A6N6 4 FatTwin static rail set supports 28 33 5 inch depth rail MCP 290 41803 0N 1 Note the...
Страница 9: ...able unit that may be removed from the chassis The nodes are connected to the server backplane by means of an adapter card Note A guide pin is located between the upper and lower nodes on the inner ch...
Страница 10: ...Socket SP3 Memory per node Support for up to 2TB Registered ECC DDR4 3200MHz SDRAM in 8 slots Chipset System on Chip Expansion Slots per node 1x PCIe 4 0 x16 slot low profile riser 1x PCIe 4 0 x8 inte...
Страница 11: ...when flashing 6 HDD Fail LED Indicates a failed hard drive 7 Release Latch Drive carrier release latch to remove from drive bay Figure 1 1 System Front View 1 5 Server Features Front Features The CSE...
Страница 12: ...several states as noted in the table below 4 UID Button The Unit ID UID button is used to turn on or off the UID LED to more easily locate the server in racks and server banks Information LED Status D...
Страница 13: ...ils Power supplies are independent and electrically isolated from the opposite side nodes Figure 1 3 System Rear View Rear Features The illustration below shows the features included on the rear of th...
Страница 14: ...DIMMH1 DIMMG1 DIMMF1 DIMME1 JNVME2 JNVME1 M 2 M1 M 2 M2 M 2 M4 M 2 M3 JVGA1 AIOM UID_LED DIMMA1 DIMMB1 DIMMC1 DIMMD1 JSXB2 I SATA0 I SATA1 JSD1 JSD2 JNVME4 JPWR2 JNVME3 JPWR1 JF1 JPWR_HDD2 JPWR_HDD3...
Страница 15: ...JF1 Front control panel JIPMB1 4 pin BMC external IC header JLAN1 Rear LAN1 port JNVME1 JNVME4 Internal NVMe ports JPWR1 12V 8 pin CPU core power supply connector JPWR2 0V ground connector JPWR_HDD1 3...
Страница 16: ...x16 P1 0 15 P2 0 15 lane reversal PCIe x16 Slot G0 0 3 P0 P1 P2 P3 G3 G2 G1 G0 RJ45 CPU USB3 0 1 VGA COM P0 0 7 SATA x8 SlimSAS x4 2 PCIe x16 G2 4 G2 5 PCIe x8 G0 8 15 lane reversal PCIe x8 Riser Slot...
Страница 17: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...
Страница 18: ...er from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always ke...
Страница 19: ...n Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the di...
Страница 20: ...provided You should also refer to the installation instructions that came with the specific rack you are using Identifying the Rails The rack rails and the related hardware should have been included w...
Страница 21: ...manner again keeping in mind that the rails are left right specific You will also need to attach the rail brackets when installng into a telco rack Note Both front chassis rails and the rack rails hav...
Страница 22: ...ding rail guide facing the inside of the rack and the rollers toward the front of the rack 2 Screw the assembly securely to the rack 3 Attach the other assembly to the other side of the rack making su...
Страница 23: ...e sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pull the chassis...
Страница 24: ...ing System Power Use the following procedure to ensure that power has been removed from the entire system 1 Use the operating system to power down all nodes 2 After all nodes have powered down disconn...
Страница 25: ...located in the node will shut down Removing a Node 1 Power down the node with the operating system If you shut down a node with the control panel you risk losing data 2 Grasp the node by the handles...
Страница 26: ...oward the rear of the node until it reaches the unlocked position 3 Lift the top cover up and off the node 4 Check that all ventilation openings on the top cover and the top of the chassis are clear a...
Страница 27: ...a T20 screwdriver when opening closing the CPU socket Always connect the power cord last and always remove it before adding removing or changing any hardware components Make sure that you install the...
Страница 28: ...holding down Force Frame in the sequence of 3 2 1 The screws are numbered on the Force Frame next to each screw hole Screw 1 Screw 2 Screw 3 Force Frame 2 The spring loaded Force Frame will raise up...
Страница 29: ...ip of the Rail Frame lift it to a position so you can do the next step of removing the External Cap Note The Rail Frame is spring loaded so keep a secure grip on it as you lift it so it does not snap...
Страница 30: ...tically upwards to remove the PnP Cover Cap Warning The exposed socket contacts are extremely vulnerable and can be damaged easily Do not touch or drop objects onto the contacts and be careful removin...
Страница 31: ...e and hold it in place until it is seated in the Socket housing Note that the Force Frame is spring loaded and has to be held in place before it is secured Important Use a torque screwdriver set it at...
Страница 32: ...heatsink down till it rests securely over the four screw holes on CPU Package on the socket frame 2 Using a diagonal pattern tighten the four screws down on the heatsink in a clockwise fashion till it...
Страница 33: ...hat the Rail Frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the Carrier Frame and pull upwards to extract it from the Rail Frame Return the Carrier Fr...
Страница 34: ...tables below for additional memory information 1R 1 package rank of SDP DRAMs 2R 2 package rank of SDP DRAMs 2DR 2 package rank of DDP DRAMs 4DR 4 package rank of DDP DRAMs 2S2R 2S4R 2S8R 2 package r...
Страница 35: ...DIMM The motherboard will support odd numbered modules 1 or 3 modules installed However to achieve the best memory performance a balanced memory population is recommended DIMME1 DIMMF1 DIMMG1 DIMMH1 D...
Страница 36: ...the memory slot 4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Press both ends of the module straight down into the slot until the module snaps...
Страница 37: ...holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may rel...
Страница 38: ...e into the carrier with the PCB side facing down and the connector end toward the rear of the carrier 2 Align the drive in the carrier so that the screw holes of both line up Note that there are holes...
Страница 39: ...g system must have RAID support to enable the hot plug capability of the hard drives Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on...
Страница 40: ...w the instructions below Removing the Backplane Removing the Backplane from the Chassis 1 Remove the node from the chassis and remove the cover from the node 2 Remove the air shroud 3 Ensure that all...
Страница 41: ...d from the bays in the front of the node 2 Ease the backplane forward against the front of the chassis 3 Align the mounting holes in the backplane with the holes in the chassis Replace the four screws...
Страница 42: ...variety of card sizes with increased functionality and storage efficiency Installing M 2 Drives 1 Remove power from the system and then remove the top cover as described in Sections 3 1 and 3 2 2 Inse...
Страница 43: ...d 3 5 drives 1 Remove the mounting screw that holds the expansion slot shield in place 2 Lift the shield out 3 Secure the expansion card to the shield using the same screw just removed 4 Install the e...
Страница 44: ...FatTwin AS F2014S RNTR User s Manual 44 Figure 3 11 Installing the PCIe Slot Bracket Assembly w 2 5 rear drive bays Figure 3 10 Installing an Expansion Card w 3 5 rear drive bays Opening Tab...
Страница 45: ...ule selected To install a module use the procedure below Installing an AIOM module 1 Remove the AIOM bracket by unscrewing two screws one on the side of the node tray one underneath 2 Remove one screw...
Страница 46: ...ove the cover from the node 2 Disconnect the wiring to all three fans 3 Lift the fan tray up and out of the node 4 Push upward on the underside of the failed fan to remove it from the fan tray Install...
Страница 47: ...1 Make sure that the motherboard and all components are properly installed in each node 2 Place the air shroud over the motherboard as illustrated below The air shroud sits behind the system fans and...
Страница 48: ...t powering down the system Replacement modules can be ordered directly from Supermicro An amber light on the power supply is illuminated when the power is switched off A green light indicates that the...
Страница 49: ...he Safety Precautions in Chapter 3 before installing or removing components 4 1 Power Connections 12V 8 pin Auxiliary Power Connector JPWR1 is an 8 pin ATX power input to provide core power to the pro...
Страница 50: ...3 are backward compatible with traditional 3 pin fans The onboard fan speeds are controlled by Thermal Management via Hardware Monitoring in the BMC When using Thermal Management setting please use al...
Страница 51: ...Trusted Platform Module TPM which is available from a third party vendor A TPM is a security device that supports encryption and authentication in hard drives It enables the motherboard to deny acces...
Страница 52: ...le here to use the IPMB I2 C connection on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Front Control Panel JF1 contains header pins for various butto...
Страница 53: ...ee the figure below for the locations and descriptions of the various I O ports on the rear of the motherboard 1 Figure 4 2 Rear I O Port Locations Rear I O Ports Description Description 1 VGA Port 3...
Страница 54: ...dicator provides easy identification of a system that may be in need of service Note UID can be triggered with the onboard UID switch or via IPMI For more information on IPMI please refer to the IPMI...
Страница 55: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...
Страница 56: ...Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disable it Watch Dog Jumper Settings Jumpe...
Страница 57: ...ink LED Connection Link Speed Indicator LED Color Definition Orange 1 Gb s Green 10 Gb s Activity LED Color State Definition None No Connection None Off Link Green Flashing Active BMC Heartbeat LED LE...
Страница 58: ...ted on our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD d...
Страница 59: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...
Страница 60: ...referred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash...
Страница 61: ...email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Ma...
Страница 62: ...e several BIOS settings that are related to IPMI For general documentation and information on IPMI visit our website at https www supermicro com en solutions management software bmc resources BMC ADMI...
Страница 63: ...her keys are used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Graye...
Страница 64: ...System Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to mov...
Страница 65: ...plays the date when the version of the BIOS ROM used in the system was built CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Memory This fe...
Страница 66: ...ss the submenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select En...
Страница 67: ...ly reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer...
Страница 68: ...Level 1 Fixed PSP Recovery BL Ver SMU FW Version ABL Version PSP Directory Level 2 Updateable PSP Bootloader Version SMU FW Version ABL Version ACPI Settings PCI AER Support The options are Disabled a...
Страница 69: ...t specified by the user Select Auto to allow the BIOS to automatically assign the base I O and IRQ address The options are Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 1...
Страница 70: ...sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits...
Страница 71: ...ion support The options are Disabled and Enabled Legacy OS Console Redirection Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support The options a...
Страница 72: ...transmission size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set...
Страница 73: ...esigned for the Windows OS The options are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Redirection After BIOS POST Use this feature to enable or disable legacy Console Redirection after BIOS POST When set...
Страница 74: ...ol Use this item to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start s...
Страница 75: ...he number of CCDs to be used The options include Auto 2 CCDs 3 CCDs 4 CCDs and 6 CCDs Core Control This sets the number of cores to be used by your system Once this option has been used to remove any...
Страница 76: ...ion has been used to remove any cores a power cycle is required in order for future selections to take effect The options include Auto TWO 1 1 FOUR 2 2 and SIX 3 3 L1 Stream HW Prefetcher Allows you t...
Страница 77: ...iguration Determinism Control Use this setting to configure the Determinism Slider Options include Manual and Auto cTDP Control Use this setting to configure the cTDP Control Options include Manual an...
Страница 78: ...ontrols interleave memory blocks across the DRAM chip for node 0 The options are Disabled and Auto BankGroupSwap This setting controls the Bank Group Swap The options are Enabled Disabled and Auto DRA...
Страница 79: ...isabled and Enabled VGA Priority Use this setting to select between onboard or offboard VGA support The options are Onboard and Offboard NVMe Firmware Source Use this setting to select between the AMI...
Страница 80: ...rd NVMe1 The options include Disabled and Legacy Onboard NVMe2 Option ROM Select which firmware function is to be loaded for onboard NVMe2 The options include Disabled and Legacy Onboard NVMe3 Option...
Страница 81: ...ll not be available IPv6 PXE Support This setting allows you to Disable or Enable IPv6 PXE boot support If disabled IPv6 PXE boot support will not be available IPv6 HTTP Support This setting allows yo...
Страница 82: ...ns are Enabled and Disabled SATA Configuration This section displays the detected SATA devices installed on the system SATA Information SATA Enable This item enables or disables the onboard SATA contr...
Страница 83: ...eed 75 characters Boot URI This option is an input field used to enter a web or network address to point to the HTTP boot files This supports the HTTP or HTTPS protocols only Instance of Priority 2 De...
Страница 84: ...address for this computer This should be in decimal and in dotted quad form i e 172 31 0 1 Local DNS Servers This item sets the address for the local DNS servers for this computer This should be in de...
Страница 85: ...ion GUID Commit Changes and Exit Use this feature to save all changes and exit TLS settings Discard Changes and Exit Use this feature to discard all changes and exit TLS settings Delete Certification...
Страница 86: ...atform Management Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI STATUS This item indicates the status of the IPMI firmware insta...
Страница 87: ...election This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default setting is Shared LAN Configuratio...
Страница 88: ...led and Disabled If the item above is set to Enabled the following items will become available for configuration Configuration Address Source This feature allows the user to select the source of the I...
Страница 89: ...BIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing Settings Erase Event Log Select Yes to erase all err...
Страница 90: ...abled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This i...
Страница 91: ...te a new or change an existing Administrator password Note that if the Administrator Password is erased the User Password will be cleared as well Password Check Select Setup for the system to check fo...
Страница 92: ...ication Options include Standard and Custom CSM Support Options are Enabled and Disabled Key Management Options are Enabled and Disabled Provision Factory Defaults When Enabled installs factory defaul...
Страница 93: ...LEGACY to EFI Support This option Disables or Enables the system to boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities This option prioritizes the order of...
Страница 94: ...boot during startup The settings are any pre defined boot device and UEFI Built in EFI shell UEFI Application Boot Priorities This feature allows the user to specify which UEFI devices are boot device...
Страница 95: ...making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset...
Страница 96: ...maximum performance Save as User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future us...
Страница 97: ...r assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These...
Страница 98: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...
Страница 99: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...
Страница 100: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...
Страница 101: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...
Страница 102: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...
Страница 103: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...
Страница 104: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...
Страница 105: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...
Страница 106: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...
Страница 107: ...aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All co...
Страница 108: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...
Страница 109: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...
Страница 110: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...
Страница 111: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...
Страница 112: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...
Страница 113: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...
Страница 114: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...
Страница 115: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto ut...
Страница 116: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...
Страница 117: ...x8 1x AIOM networking slot PCIe 4 0 x16 M 2 Interface 4x PCIe 4 0 x4 Motherboard per node One H12SSFR AN6 motherboard proprietary form factor 18 73 L x 8 54 W 475 74 mm x 216 92 mm Chassis CSE F424AS3...
Страница 118: ...BS 61000 4 8 EN BS 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive Product Safety 2014 35 EU LVD Directive UL CSA 62368 1 USA and Canada IEC EN 623...
Страница 119: ...e The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...
Страница 120: ...UEFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD...
Страница 121: ...you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed with...
Страница 122: ...oot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built...
Страница 123: ...rupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power suppl...
Страница 124: ...Declaration of the Presence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 0...
Страница 125: ...125 Appendix C Chinese Safety Warnings 100 127V 60 50Hz 12 11A each input 200 240V 60 50Hz 10 9 8A each input 150 3...