Appendix A: Power Supply Specifications

31

Appendix A  

 

Power Supply Specifications

This appendix lists the power supply specifications for your chassis.

800/860W

MFR Part #

PWS-860P-1R2

Total Output 

Power

800W with Input 100 - 127Vac

860W with Input 200 - 240Vac

860W with Input 200 - 240Vdc

Rated AC Voltage

100-240V

50-60Hz

10-5A

+5V standby

Max: 4A, Min: 0A

+12V

Max: 66.6A (100Vac - 127Vac)

Max: 71.6A (200Vac - 240Vac)

Содержание CSE-LA15-AW Series

Страница 1: ...USER S MANUAL Revision 1 0 CSE LA15 AW Cloud DC Chassis Series...

Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wdl Product safety info http www superm...

Страница 4: ...acement Components 11 1 5 Returning Merchandise for Service 11 Chapter 2 Chassis Installation 2 1 Overview 12 2 2 Preparing for Setup 12 Choosing a Setup Location 12 Rack Precautions 12 System Chassis...

Страница 5: ...omponent Installation 3 1 Removing Power 20 3 2 Accessing the System 21 3 3 Chassis Components 22 3 5 Drive 23 2 5 Drive 24 Fans 25 Air Shrouds 26 AIOM Cards 27 PCIe Expansion Cards 28 Power Supply 30...

Страница 6: ...o com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support...

Страница 7: ...shipped in and note if it was damaged in any way If any equipment appears damaged please file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that wil...

Страница 8: ...ower is being supplied to the system power supply units This LED is illuminated when the system is operating normally 7 Reset button The hardware reset button is used to reboot the system if needed 8...

Страница 9: ...rations using a controller the meaning of the status indicator is described in the table below For OS RAID or non RAID configurations some LED indications are not supported such as hot spares Drive Ca...

Страница 10: ...er supply modules display status lights Figure 1 3 Chassis Rear View 4 6 7 1 2 2 3 3 5 8 Chassis Rear Features Item Description 1 1U 80 Plus Platinum redundant power supply 1 1 2 Full height half leng...

Страница 11: ...nline at https www supermicro com en support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure t...

Страница 12: ...the rack Please read this section in its entirety before you begin the installation Choosing a Setup Location The chassis should be situated in a clean dust free area that is well ventilated Avoid ar...

Страница 13: ...ver from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always k...

Страница 14: ...lar attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing th...

Страница 15: ...provided You should also refer to the installation instructions that came with the specific rack you are using If you are installing into a two post telco rack skip to that section later in this chap...

Страница 16: ...rack C Push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack Keep the rail horizontal 2 Adjust the rail to reach just past the full depth of your r...

Страница 17: ...ll bearing shuttle is locked at the front of the middle rail 2 Align the rear of the chassis rails with the middle rails and then push evenly on both sides of the chassis until it clicks into the full...

Страница 18: ...assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pull the chassis forward out...

Страница 19: ...chassis should be positioned so that the weight is balanced between front and back 2 Attach the two front brackets to each side of the chassis then the two rear brackets positioned with just enough sp...

Страница 20: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...

Страница 21: ...the Top Cover 1 Unscrew the thumbscrew at the rear of the cover and slide the cover toward the rear 2 Lift the top cover up Check that all ventilation openings on the top cover and the top of the cha...

Страница 22: ...emoval from the chassis These carriers also help promote proper airflow Each carrier has a small space on the front to receive a label orange or purple to help distinguish NVMe or SAS SATA Note Enterp...

Страница 23: ...Position the drive above the carrier with the PCB side facing down and the connector end toward the rear of the carrier 3 Tilt the drive to insert it onto the two posts on the left inside of the carri...

Страница 24: ...my drive 2 Install the drive directly into the tray with four screws underneath 3 Insert the drive carrier into its bay keeping the release button on the right When the carrier reaches the rear of the...

Страница 25: ...Positions 1 6 5 4 3 2 Changing a System Fan 1 Determine which fan is failing If possible use the BMC Remove the chassis lid to examine the fans 2 Power down the system 3 Remove the power cable of the...

Страница 26: ...Air Shrouds Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency They do not require screws to install Installing the Standard Air Shrouds Position the air shrouds as illustrated in...

Страница 27: ...fferences below when using a dual CPU motherboard AIOM Configurations Slot Mechanical Electrical 1 Small Form Factor OCP 3 0 x16 CPU1 2 Small Form Factor OCP 3 0 x16 CPU2 Installing AIOM 1 Remove the...

Страница 28: ...rboard Installing an Expansion Card 1 Power down the system as described in section 3 1 and remove the cover 2 Pull the riser bracket up and out using the pull tabs Figure 3 11 Riser Card Bracket and...

Страница 29: ...aligning the expansion card backplate with the open slot in the rear of the chassis Flip the small plastic lever to secure the backplate 4 Insert the riser card into the motherboard expansion slot wh...

Страница 30: ...en When illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the system Blinking Amber When blinking indicates...

Страница 31: ...s the power supply specifications for your chassis 800 860W MFR Part PWS 860P 1R2 Total Output Power 800W with Input 100 127Vac 860W with Input 200 240Vac 860W with Input 200 240Vdc Rated AC Voltage 1...

Страница 32: ...ent for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 33: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 34: ...t werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers...

Страница 35: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 36: ...orrientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de...

Страница 37: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 38: ...roomkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipme...

Страница 39: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 40: ...cceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L...

Страница 41: ...mblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorr...

Страница 42: ...ikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection...

Страница 43: ...mloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atten...

Страница 44: ...ung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriq...

Страница 45: ...umplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is g...

Страница 46: ...ationale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled a...

Страница 47: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 48: ...los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soi...

Страница 49: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro UL...

Страница 50: ...qu sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el produ...

Страница 51: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Отзывы: