Chapter 6: UEFI BIOS

81

•  L2 Data Cache (Size/Method)
•  L3 Cache per Scoket (Size/Method)

NB Configuration

North Bridge Configuration

Determinism Control

Use this setting to configure the Determinism Slider. The options include Manual and 

Auto

.

cTDP Control

Use this setting to configure the cTDP Control. The options include Manual and 

Auto

.

IOMMU

Use this setting to enable/disable IOMMU. The options include 

Disabled

, Enabled, and Auto.

ACS Enable

Use this setting to enable/disable ACS. The options include Enabled, Disabled and 

Auto

.

Package Power Limit Control 

Use this setting to control package power limit. The options include Manual and

 Auto

APBDIS 

Use this setting to set APBDIS. The options include 0, 1, and 

Auto

.

DF Cstates

Use this setting to enable/disable DF Cstates. The options include Disabled, Enabled, and 

Auto

.

Preferred IO 

Use this setting for Preferred IO. The options include Manual and 

Auto

.

Memory Configuration

Memory Clock

This setting allows you to select different memory clock speed. Options include 

Auto

  and  

2666 MHz, 2933 MHz, and 3200 MHz. 

Memory Interleaving

This setting controls fabric level memory interleaving. Note that the channel, die and socket 
have requirements on memory populations and it will be ignored if the memory doesn't 
support the selected option. The options are Disabled and 

Auto

.

Содержание ASG-1014S-ACR12N4H

Страница 1: ...USER S MANUAL Revision 1 0 A Server ASG 1014S ACR12N4H...

Страница 2: ...lass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...upport manuals Product drivers and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please cont...

Страница 4: ...tion 15 Rack Precautions 16 Server Precautions 16 Rack Mounting Considerations 16 Ambient Operating Temperature 16 Airflow 16 Mechanical Loading 17 Circuit Overloading 17 Reliable Ground 17 2 3 Instal...

Страница 5: ...em Fans 46 Checking the Server Air Flow 47 Overheating 47 Power Supply 48 Power Supply LEDs 49 Chapter 4 Motherboard Connections 4 1 Power Connections 50 4 2 Headers and Connectors 52 Control Panel 56...

Страница 6: ...6 Preface 6 6 Security 96 6 7 Boot 100 6 8 Save Exit 102 Appendix A Standardized Warning Statements for AC Systems Appendix B UEFI BIOS Recovery Appendix C System Specifications...

Страница 7: ...Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro...

Страница 8: ...D trays MCP 220 00162 0N 12 2 5 NVME HDD trays MCP 220 00161 0B 4 Mylar air shroud for CPU MCP 310 81305 0B 1 40mm counter rotating fans FAN 0141L4 6 1U fixed rail set for rack mounting MCP 290 00153...

Страница 9: ...o 4TB of ECC DDR4 3200 MHz speed RDIMM LRDIMM 3DS NVDIMM memory in sixteen slots Chipset System on Chip Expansion Slots Two PCIe 4 0 x16 left riser slot One PCIe 4 0 x16 right riser slot M 2 Interface...

Страница 10: ...t Blinking blue 300 msec UID has been activated using IPMI to locate the server in a rack environment Figure 1 1 Control Panel Control Panel Features Item Features Description 1 Power button The main...

Страница 11: ...t rotate the two unlocked levers outward at the same time then carefully pull Please double check that the thumbscrews that hold the rack ear brackets are fully secured before accessing the drawer Cha...

Страница 12: ...or detailed information on jumpers I O ports and JF1 front panel connec tions indicates the location of pin 1 Jumpers LED indicators not indicated are used for testing only JSXB1A JSXB2 JSXB1B JSXB1C...

Страница 13: ...m cooling fan headers JF1 Front control panel JSD1 JSD2 SATA DOM power connector JTPM1 Trusted Platform Module TPM Port 80 connector SATA16 SATA17 Onboard SATA ports via Asmedia 1061 JL1 Chassis intru...

Страница 14: ...0 DDR4 DIMM 0 DDR4 DIMM 0 DDR4 DIMM 0 DDR4 DIMM 0 DDR4 DIMM 0 USB3 0 Type A DDR4 DIMM 0 F G H B C D CPU G0 3 0 CPU G2 PCIe 3 0 SATA 23 20 CPU G2 PCIe 7 4 SATA 27 24 CPU G3 PCIe 3 0 SATA 33 30 CPU G3...

Страница 15: ...should include the rackmount hardware needed to install it into the rack Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situa...

Страница 16: ...server components at the bottom of the rack first and then work your way up Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep yo...

Страница 17: ...To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips...

Страница 18: ...ach end of the rails that latch and lock onto the square mounting holes which are located on the front and back of the server rack When these rails are secure the chassis left and right sides will sim...

Страница 19: ...engage the selected mounting hole 1 A When the top hook is rested and engaged into place push the bottom lock into the lower hole until it clicks and snaps into place Insert until bottom lock snaps in...

Страница 20: ...ilize the rack can cause the rack to tip over Slide rail mounted equipment is not to be used as a shelf or a work space The illustration below shows both the left and right rails mounted on a rack rea...

Страница 21: ...The spring latch engages when the chassis is part way in Push the server completely into the rack Figure 2 4 Installing the Server into a Rack Note The figure above is for illustrative purposes only...

Страница 22: ...e reverse of the installation procedure Push bottom lock button Pull up and away from the rack 1 A 1 B The chassis can then be secured to the rack by two thumb screws located on the left and right of...

Страница 23: ...se follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing n...

Страница 24: ...assis Cover 1 Loosen the two thumb screws on the front of the chassis to unlock the levers on both sides Rotate counter clockwise to unlock clockwise to lock 2 Pull out the two levers at the same time...

Страница 25: ...ket before you install the CPU heatsink If you buy a CPU separately make sure that you use an AMD certified heatsink only Make sure to install the motherboard into the chassis before you install the C...

Страница 26: ...up to its stopping position 3 Lift the rail frame up by gripping the lift tabs near the front end of the rail frame While keeping a secure grip of the rail frame lift it to a position so you can do th...

Страница 27: ...ed Grip the handle of the carrier frame CPU package assembly from its shipping tray and while gripping the handle align the flanges of the carrier frame onto the rails of the rail frame so its pins wi...

Страница 28: ...again and double check that the CPU is aligned properly 7 Lift up the rail frame till it securely rests in upright position Then remove the PnP cover cap from the CPU socket below Grip the two lift t...

Страница 29: ...e force frame is spring loaded and has to be held in place before it is secured Important Use a torque screwdriver set it at 16 1 kgf cm 14 0 lbf in with a Torx T20 screw head bit to prevent damage to...

Страница 30: ...m holes 1 2 3 in order When finished the force frame will be secure over both the rail frame and CPU package 11 After the force frame is secured and the CPU package is in place now you must install th...

Страница 31: ...r screws down on the heatsink in a clockwise fashion till it is secure The heatsink will now be secured and you have finished installing the processor and heatsink onto the motherboard Repeat this pro...

Страница 32: ...hat the rail frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the carrier frame and pull upwards to extract it from the rail frame Return the carrier fr...

Страница 33: ...he table below for additional memory information Populating RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS DDR4 Memory Modules with 7002 7003 Processor Type DIMM Population Maximum DIMM Capacity GB Maximum Frequen...

Страница 34: ...MM modules of the same type size and speed Mixed DIMM speeds can be installed However all DIMMs will run at the speed of the slowest DIMM The motherboard will support odd numbered modules 1 or 3 modul...

Страница 35: ...annel pair in the system e g A C E G Processors and their Corresponding Memory Modules Channel CPU A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 1 DIMM Not Recommended CPU1 V 2 DIMMs Not Recommended...

Страница 36: ...int on the memory slot 4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Press both ends of the module straight down into the slot until the module...

Страница 37: ...bed in Section 3 1 and remove the rear cover 2 Remove the riser card bracket from the system 3 Install the add on card in your preferred slot on the riser bracket and secure with the provided screws 4...

Страница 38: ...this server and are not active Figure 3 4 Backplane LEDs Backplane LED Activity Status LED Color Status Blinking Pattern Applicable to Devices ACT LED Green or Blue Activity Blinking during I O SAS SA...

Страница 39: ...der with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release...

Страница 40: ...ans of three small horizontal backplanes that supports four 3 5 HDD each and each row of four 3 5 HDDs attaches to the subsequent backplane Replacing a Hard Drive 1 There is no need to power down 2 Lo...

Страница 41: ...A Server ASG 1014S ACR12N4H User s Manual 41 Figure 3 7 Adding and Replacing Hard Drives Backplanes 3 5 HDD Latch Pull handle up...

Страница 42: ...d activity Red Blinking with two blinks and one stop at 1 Hz Indicates a hot spare drive Red On for five seconds then off Indicates a power on drive status Red Blinking at 4 Hz Identifying or locating...

Страница 43: ...The Activity LED turns blue Figure 3 4 IPMI Screenshot Checking the Temperature of an NVMe Drive There are two ways to check using IPMI Checking a Drive System Component Info Sensor Clicking on the A...

Страница 44: ...ling an M 2 device The motherboard can accommodate an M 2 solid state drive SSD The M 2 socket supports NVMe PCIe 4 0 x2 cards in the 2280 or 22110 form factors The 22110 form factor is recommended be...

Страница 45: ...the motherboard lift up its top square latch and use gentle force to pull it out of the hole 3 Move and place the standoff plug in the proper hole 4 Insert the M 2 2280 device at a slight angle in the...

Страница 46: ...Power down as described in Section 3 1 3 Remove the failed fan s power cable from the motherboard 4 Lift the failed fan from the fan housing and out of the chassis 5 Place the new fan into the vacant...

Страница 47: ...e Control Panel in Chapter 1 for details Overheating There are several possible responses if the system overheats Overheat Temperature Setting Some backplanes allow the overheat temperature to be set...

Страница 48: ...ro or authorized distributors These power supplies are auto switching capable This feature enables them to automatically sense the input voltage and operate at a 100 120v or 180 240v as needed by the...

Страница 49: ...inking this system power supply temperature has reached 63C The system will automatically power down when the power supply temperature reaches 70C and restart when the power supply temperature goes be...

Страница 50: ...utions in Appendix B before installing or removing components 4 1 Power Connections Two power connections on the H12SSW NTR must be connected to the power supply The wiring is included with the power...

Страница 51: ...r Connector JPWR1 JPWR1 is an 8 pin ATX power input to provide auxiliary power to the processor Refer to the table below for pin definitions 12V 8 pin Power Connector Pin Definitions Pins Definition 1...

Страница 52: ...Definition 1 Ground Black 2 12V Red 3 Tachometer Yellow 4 PWM Control Blue Disk On Module Power Connector JSD1 JSD2 The Disk On Module DOM power connector at JSD1 provides 5V power to a solid state D...

Страница 53: ...ional PCIe M 2 Connector M 2 C1 M 2 C2 The PCIe M 2 connectors are for devices such as memory cards wireless adapters etc These devices must conform to the PCIe M 2 specifications formerly known as NG...

Страница 54: ...USB3_RN 3 Stda_SSRX 17 USB3_RP 4 GND 16 GNd 5 Stda_SSTX 15 USB3_TN 6 Stda_SSTX 14 USB3_TP 7 GND 13 GND 8 D 12 USB_N 9 D 11 USB_P 10 GND x x Onboard Battery BT1 The onboard back up battery is located...

Страница 55: ...inform you when the chassis is opened Chassis Intrusion Pin Definitions Pins Definition 1 Ground 2 Intrusion Input IPMB System Management Bus Header JIPMB1 A System Management Bus header for IPMI 2 0...

Страница 56: ...ower Switch Reset Switch Power Fail LED UID LED NIC2 LED NIC1 LED HDD LED UID Switch Power LED KEY no pin NMI Switch Shift 19 20 1 2 Power Switch The Power Switch connection is located on pins 1 and 2...

Страница 57: ...LED 10 NIC2 LED 11 NIC1 LED 12 NIC1 LED Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch is located on the I O backplane and two UID LED indicators are located on the motherboard...

Страница 58: ...tch 14 HDD LED Power LED The Power LED connection is located on pins 15 and 16 of JF1 Attach a cable to Pin 15 and Pin 16 to show system power status Refer to the table below for pin definitions Power...

Страница 59: ...rt 5 USB 2 3 0 9 VGA Port 2 IPMI LAN Port 6 USB 3 3 0 10 UID Switch UID LED 3 USB 0 3 0 7 LAN Port 1 4 USB 1 3 0 8 LAN Port 2 1 5 4 3 2 6 7 8 9 10 Universal Serial Bus USB Ports There are four USB 3 0...

Страница 60: ...off the LED indicators The UID Indicator provides easy identification of a system that may be in need of service See page 36 for the front panel UID LED header location on JF1 Note UID can also be tr...

Страница 61: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 62: ...on that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disable it Watch Dog Jumper S...

Страница 63: ...UID Indicator to mark the system so the system can be easily identified whether on the front or back e g a system rack with multiple units installed UID LED LED Indicator Color State Definition Blue S...

Страница 64: ...posted on our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DV...

Страница 65: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 66: ...f preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the fl...

Страница 67: ...n remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP services to optimize the efficien...

Страница 68: ...such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cann...

Страница 69: ...Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move betwee...

Страница 70: ...is item displays the date when the version of the BIOS ROM used in the system was built CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Mem...

Страница 71: ...ubmenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to...

Страница 72: ...automatically reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watc...

Страница 73: ...er Version SMU FW Version ABL Version ACPI Settings PCI AER Support Use this setting to enable disable PCI AER Support The options are Disabled and Enabled High Precision Event Timer The High Precisio...

Страница 74: ...4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 SOL Configuration Serial Port Select Enabled to enable the selected onboard s...

Страница 75: ...y bit can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is s...

Страница 76: ...r disable legacy console redirection after BIOS POST When set to BootLoader legacy console redirection is disabled before booting the OS When set to Always Enable legacy console redirection remains en...

Страница 77: ...ong with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data p...

Страница 78: ...emains enabled when booting the OS The options are Always Enable and BootLoader Legacy Console Redirection Legacy Console Redirection Settings Redirection COM Port For this setting select a COM port t...

Страница 79: ...Send a Start signal to start sending data when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff Data Bits Use this feature to set the data transmission size fo...

Страница 80: ...used for Core Control The options include Auto TWO 1 1 FOUR 2 2 and SIX 3 3 L1 Stream HW Prefetcher L2 Stream HW Prefetcher This setting is used to enable or disable the L1 L2 Stream Hardware Prefetc...

Страница 81: ...this setting to control package power limit The options include Manual and Auto APBDIS Use this setting to set APBDIS The options include 0 1 and Auto DF Cstates Use this setting to enable disable DF...

Страница 82: ...rmation These sections are for informational purposes They will display some details about the detected memory according to each CPU on the motherboard such as Detected Size per slot in MB Current Spe...

Страница 83: ...between onboard or offboard VGA support The options are Onboard and Offboard NVMe Firmware Source Use this setting to select between the AMI Native firmware support or the device vendor defined firmwa...

Страница 84: ...IPv4 PXE Support This setting allows you to Disable or Enable IPv4 PXE boot support If disabled IPv4 PXE boot support will not be available IPv4 HTTP Support This setting allows you to Disable or Enab...

Страница 85: ...g will enable or disable support for USB mass storage drivers The options are Enabled and Disabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide...

Страница 86: ...SATA devices connected and are detected HTTP Boot Configuration HTTP Boot One Time When the HTTP boot option is created this option when enabled will allow the system to boot via HTTP the first time...

Страница 87: ...ble DHCP This feature allows the user to select the source of the IP address for this computer If Disabled is selected you will need to know the local IP address of this computer and enter it to the s...

Страница 88: ...P address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected the BIOS will search for a...

Страница 89: ...discard all changes and exit TLS settings Certification GUID Commit Changes and Exit Use this feature to save all changes and exit TLS settings Discard Changes and Exit Use this feature to discard al...

Страница 90: ...t Select this feature when you want to exit from this submenu after you ve created a raw RAM disk Discard Exit Select this feature when you want to abandon the changes you ve made and to exit from the...

Страница 91: ...ce IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status Baseboard Management Controller This item indicates the status of the IPMI firmwar...

Страница 92: ...C Network Configuration IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The default...

Страница 93: ...sable and Enable Configure IPV6 Support This section displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configur...

Страница 94: ...onfigure SMBIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled...

Страница 95: ...CI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is u...

Страница 96: ...assword Note that if the Administrator Password is erased the User Password will be cleared as well Password Check Select Setup for the system to check for a password at Setup Select Always for the sy...

Страница 97: ...s in the Setup mode The options are Disabled and Enabled Restore Factory Keys Select and press Yes to restore factory default secure boot keys and key variables Also it will reset the system to the Us...

Страница 98: ...lect No to load the KEK from a file The options are Yes and No Append Key Select Yes to add the KEK from the manufacturer s defaults list to the existing KEK Select No to load the KEK from a file The...

Страница 99: ...oad the DBT from a file The options are Yes and No OsRecovery Signature This item uploads and installs an OSRecovery Signature You may select options for Update for a factory default key or select App...

Страница 100: ...e system to boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Ente...

Страница 101: ...ation Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Order 1 NETWORK Drive BBS Priorities This feature allows the user to specify which UEFI netw...

Страница 102: ...etup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this opti...

Страница 103: ...ormance Save as User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore Use...

Страница 104: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 105: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 106: ...erken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aa...

Страница 107: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 108: ...entes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l in...

Страница 109: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 110: ...mkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment...

Страница 111: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 112: ...so a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 113: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 114: ...t aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...

Страница 115: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 116: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...

Страница 117: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 118: ...onale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled acco...

Страница 119: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 120: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...

Страница 121: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 122: ...ur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...

Страница 123: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 124: ...mage The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the syst...

Страница 125: ...into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website at www supermicro com to download the BIOS package Extr...

Страница 126: ...as shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interr...

Страница 127: ...he prompt to start the BIOS update process Note Do not interrupt this process until the BIOS flashing is complete 7 Press Del continuously during system boot to enter the BIOS Setup utility From the t...

Страница 128: ...above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility...

Страница 129: ...PCI Expansion Slots Two PCIe 4 0 x16 full profile half length left riser slot One PCIe 4 0 x16 low profile half length right riser slot M 2 Interface 2 PCI E 4 0 x2 M 2 Form Factor 2280 22110 M 2 Key...

Страница 130: ...61000 4 6 EN 61000 4 8 EN 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Directive UL CSA 6...