9. 

When the UEFI Shell prompt appears, type fs# to change the device directory path. Go 
to the directory which contains the BIOS package extracted earlier from Step 7. Enter 
flash.nsh BIOSname.### at the prompt to start the BIOS update process.

Note:

 

Do not interrupt this process

 until the BIOS flashing is complete.

10.  The screen below indicates that the BIOS update process is complete. Unplug the AC 

power cable from the power supply, clear the CMOS, and plug the AC power cable in 

the power supply again to power on the system.

11. 

 Press <Del> continuously to enter the BIOS setup utility.

12. 

Press <F3> to load the default settings.

13.  After loading the default settings, press <F4> to save the settings and exit the BIOS 

setup utility.

Содержание A2SDV-4C-LN10PF

Страница 1: ...USER MANUAL Revision 1 0 A2SDV 4C LN8F A2SDV 8C LN8F A2SDV 4C LN10PF A2SDV 8C LN10PF...

Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...

Страница 3: ...this model are one M 2 M Key for storage one M 2 B Key for storage PCI E devices eight Gigabit RJ45 LAN ports two Gigabit SFP LAN ports expandability via either slot6 or slot7 and the reliability dep...

Страница 4: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermic...

Страница 5: ...Environmental Temperature Control 21 System Resource Alert 21 1 5 ACPI Features 22 1 6 Power Supply 22 1 7 Super I O 22 Chapter 2 Installation 2 1 Static Sensitive Devices 23 Precautions 23 Unpacking...

Страница 6: ...stem s Setup Configuration 58 When the System Becomes Unstable 58 3 2 Technical Support Procedures 60 3 3 Frequently Asked Questions 61 3 4 Battery Removal and Installation 62 Battery Removal 62 Prope...

Страница 7: ...nstallation B 1 Installing Software Programs 104 Appendix C Standardized Warning Statements Battery Handling 106 Product Disposal 108 Appendix D UEFI BIOS Recovery Appendix E Dual Boot Block BIOS Boot...

Страница 8: ...at the following items have all been included with your motherboard If anything listed here is damaged or missing contact your retailer The following items are included in the retail box 1 1 Checklist...

Страница 9: ...9 Chapter 1 Introduction Figure 1 1 A2SDV 4C LN8F Motherboard Image...

Страница 10: ...10 A2SDV 4C 8C LN8F LN10PF User s Manual Figure 1 2 A2SDV 4C LN10PF Motherboard Image...

Страница 11: ...11 Chapter 1 Introduction Figure 1 3 A2SDV 8C LN10F Motherboard Image...

Страница 12: ...JMD2 JMD1 1 74 75 12 13 1 JPW1 JPI2C1 JSD1 BT1 SRW2 SRW1 SRW3 SRW4 JUIDB JPL1 JI2C2 JI2C1 JWD1 JPG1 JPME2 JSEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 DIMMA1 DIMMB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 J...

Страница 13: ...SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 Notes USB 3 1 Gen 1 is also referred to as USB 3 0 See Chapter 2 for detailed informati...

Страница 14: ...8 4 8 Cache 8MB 16MB 8MB 16MB Processor Base Frequency 2 2GHz 2 2GHz 2 2GHz 2 2GHz Intel Turbo Boost Frequency 2 2GHz 2 2GHz 2 2GHz 2 2GHz SoC TDP 16W 25W 16W 25W SATA3 Ports 3 5 1 3 5 Expansion Slot6...

Страница 15: ...E Slot 6 7 Selection Pins 1 2 Slot 7 JWD1 Watch Dog Timer Pins 1 2 Reset LED Description Status LED1 Power LED Solid Green Power On LEDM1 BMC Heartbeat Blinking Green BMC Normal UIDLED1 UID LED Solid...

Страница 16: ...SFPLED1 SFP LAN LED Board Cable Connector for FPB FPE300 LED10 LN10PF SKUs Only JSMB1 System Management Bus Header JTPM1 Trusted Platform Module TPM JUIDB Unit ID Button LAN1 LAN10 LN8F LAN1 8 Gigabit...

Страница 17: ...RJ45 LAN with Intel C3000 SoC Quad RJ45 LAN with Intel i350 AM4 Dual SFP LAN with Intel i210 IS LN10PF SKUs only Baseboard Management Controller BMC ASpeed AST2400 Baseboard Controller Graphics VGA G...

Страница 18: ...nagement PECI Platform Environment Control Interface 3 2 support IPMI 2 0 System resource alert via SuperDoctor 5 Watch Dog NMI Chassis Intrusion header and detection Power supply monitoring LED Indic...

Страница 19: ...CIe 3 0_x4 8GT s HSIO 3 0 PCIE x4 HSIO 7 6 PCIE x2 M 2 2242 2280 M KEY PCIE SATA SSD SATA III 6Gb s HSIO 9 11 15 16 17 SATA III RGMII2 5X SATA III USB2 0 3 USB 2 0 0 Intel FCBGA1310 C3000 Series SMBUS...

Страница 20: ...Technology VT x Intel Virtualization Technology for Directed I O Intel VT d Intel Trusted Execution Technology Intel TXT Intel Rapid Storage Technology GbE Ethernet with RJ45 and SFP connectors 1 3 Sp...

Страница 21: ...ture Control System Health sensors monitor temperatures and voltage settings of onboard processors and the system in real time via the IPMI interface Whenever the temperature of the CPU or the system...

Страница 22: ...rom noise It is recommended that you also install a power surge protector to help avoid problems caused by power surges 1 7 Super I O The Super I O Aspeed AST2400 chip includes a data separator write...

Страница 23: ...es only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the motherboard and peripherals back into their antist...

Страница 24: ...I E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 2 2 Motherboard Installation All motherboards have standard mounting holes to fit different typ...

Страница 25: ...s needed 4 Install the motherboard into the chassis carefully to avoid damaging other motherboard components 5 Using the Phillips screwdriver insert a Phillips head 6 screw into a mounting hole on the...

Страница 26: ...CC UDIMM DDR4 memory in four memory slots Populating these DIMM slots with memory modules of the same type and size will result in interleaved memory which will improve memory performance DIMM Module...

Страница 27: ...ALWAYS POPULATE DIMMx1 FIRST LN10PF LAN1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD L...

Страница 28: ...CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 DIMM Installation 1 Insert the desired number of DIMMs into the memory slots start...

Страница 29: ...SEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 DIMMA1 DIMMB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2 I SATA3 I SATA4 I SATA0 1...

Страница 30: ...1 A ALWAYS POPULATE DIMMx1 FIRST LN10PF LAN1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HD...

Страница 31: ...JWD1 JPG1 JPME2 JSEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 DIMMA1 DIMMB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2 I SATA3...

Страница 32: ...SDV 4C LN8F REV 1 01 11 10 6 1 M 20 19 2 1 JF1 67 57 JMD2 JMD1 1 74 75 12 13 1 JPW1 JPI2C1 JSD1 BT1 SRW2 SRW1 SRW3 SRW4 JUIDB JPL1 JI2C2 JI2C1 JWD1 JPG1 JPME2 JSEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 D...

Страница 33: ...X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 1 1 UID Button 2 UID LED 2 UID Button Pin Definitions Pin Definition 1 Gro...

Страница 34: ...DIMMx1 FIRST LN10PF LAN1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH...

Страница 35: ...r 4 seconds or longer Refer to the table below for pin definitions Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Reset Button The Reset Button connection is located on pins 3 and 4...

Страница 36: ...es below for pin definitions OH Fan Fail Indicator Status State Definition Off Normal On Overheat Flashing Fan Fail OH Fan Fail LED Pin Definitions JF1 Pin Definition 7 UID LED 8 OH Fan Fail LED 1 2 1...

Страница 37: ...13 3 3V 14 HDD LED 1 2 1 HDD LED 2 PWR LED Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions Power LED Pin Definitions JF1 Pin Defini...

Страница 38: ...NMI 2 Power Fail LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table below for pin definitions NMI Button Pin Definitions JF1 Pins Definition...

Страница 39: ...CG3 CG4 CG5 L20 L19 L1 SFP1 BAR CODE BIOS LICENSE DESIGNED IN USA A2SDV 4C LN8F REV 1 01 11 10 6 1 M 20 19 2 1 JF1 67 57 JMD2 JMD1 1 74 75 12 13 1 JPW1 JPI2C1 JSD1 BT1 SRW2 SRW1 SRW3 SRW4 JUIDB JPL1 J...

Страница 40: ...B1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2 I SATA3 I SATA4 I SATA0 1 4 LEDM1 A C UIDLED1 A ALWAYS POPULATE DIMMx1 FIRST LN10PF LAN1 2 LN10PF LAN3...

Страница 41: ...8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4...

Страница 42: ...Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 Chassis Intrusion A Chassis Int...

Страница 43: ...IDB JPL1 JI2C2 JI2C1 JWD1 JPG1 JPME2 JSEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 DIMMA1 DIMMB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SA...

Страница 44: ...N1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR J...

Страница 45: ...C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2 I SATA3 I SATA4 I SATA0 1 4 LEDM1 A C UIDLED1 A ALWAYS POPULATE DIMMx1 FIRST LN10PF LAN1 2 LN10P...

Страница 46: ...1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 SATA Ports A2SDV 8C LN8F...

Страница 47: ...MMx1 FIRST LN10PF LAN1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH F...

Страница 48: ...YS POPULATE DIMMx1 FIRST LN10PF LAN1 2 LN10PF LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NI...

Страница 49: ...tween two pins to change the function of the connector Pin 1 is identified with a square solder pad on the printed circuit board See the diagram below for an example of jumping pins 1 and 2 Refer to t...

Страница 50: ...MB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2 I SATA3 I SATA4 I SATA0 1 4 LEDM1 A C UIDLED1 A ALWAYS POPULATE DIMMx1 FIRS...

Страница 51: ...PMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 1 1 Watch Dog 2 SMBus to PCI E Slots Watch Dog JWD1 controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software applicati...

Страница 52: ...JLANLED3 JLANLED2 4 JLANLED1 JSFPLED1 2 1 JFPCLED1 C A LEDT2 LEDT4 A C COM1 1 5 PRESS FIT CG13 CG11 CG7 CG6 CG1 CG2 CG3 CG4 CG5 L20 L19 L1 SFP1 BAR CODE BIOS LICENSE DESIGNED IN USA A2SDV 4C LN8F REV...

Страница 53: ...2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1 CM CODE LED1 JRT4 BMC AST2400 1 1 BIOS Recov...

Страница 54: ...C2 JI2C1 JWD1 JPG1 JPME2 JSEL1 JPL4 JPL3 JPL2 JBR1 DIMMA2 DIMMB2 DIMMA1 DIMMB1 C A LEDT1 LEDT3 A C JSMB1 JD1 2 1 JGP1 JBT1 JPH1 4 3 2 JPV1 FAN2 FAN1 FANB FAN3 FANA 1 2 20 JL1 JRT3 1 1 I SATA1 I SATA2...

Страница 55: ...LAN3 10 LN8F LAN1 8 USB 4 3 1 Gen 1 eUSB USB 2 3 USB 0 1 3 1 Gen 1 IPMI LAN CPU VGA CPU SLOT7 PCI E 3 0 X4 NMI X CPU SLOT6 PCI E 3 0 X4 PWR LED HDD LED NIC 2 NIC 1 OH FF RST X JF1 ON PWR JIPMB1 JTPM1...

Страница 56: ...luding those for the keyboard and mouse 3 Remove all add on cards 4 Install the CPU making sure it is fully seated and connect the front panel connectors to the motherboard No Power 1 Make sure that t...

Страница 57: ...e installed If the system boots check for bad DIMM modules or slots by following the Memory Errors Troubleshooting procedure in this chapter Memory Errors When a no memory beep code is issued by the s...

Страница 58: ...nk on the motherboard product page to see a list of supported memory 3 HDD support Make sure that all hard disk drives HDDs work properly Replace the bad HDDs with good ones 4 System cooling Check the...

Страница 59: ...necessary remove a component in question from the chassis and test it in isolation to make sure that it works properly Replace a bad component with a good one 5 Check and change one component at a ti...

Страница 60: ...AQs on our website http www supermicro com FAQ index php before contacting Technical Support 2 BIOS upgrades can be downloaded from our website http www supermicro com ResourceApps BIOS_IPMI_Intel htm...

Страница 61: ...mation on how to update your BIOS on our website Select your motherboard model and download the BIOS file to your computer Also check the current BIOS revision to make sure that it is newer than your...

Страница 62: ...damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulatio...

Страница 63: ...ntly displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For fa...

Страница 64: ...re used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out opti...

Страница 65: ...w keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time...

Страница 66: ...PF User s Manual 66 Memory Information Total Memory This feature displays the total size of memory available in the system Memory Speed This feature displays the default speed of the memory modules in...

Страница 67: ...re Quiet Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead...

Страница 68: ...set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Select Last Sta...

Страница 69: ...options are No Pkg C State No S0Ix and No Limit This feature is not available when CPU C State is disabled Max Core C State Use this feature to select the CPU C state The options are C1 and C6 This fe...

Страница 70: ...sable Bit support which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illeg...

Страница 71: ...Average Power Limit RAPL power limit 2 in Watts The default setting is 37 Use the or keys to define the setting Active Processor Cores Use this feature to set the number of processor cores that will...

Страница 72: ...gs will always be 4GB The options are Auto 1024M 3072M and 3072M 1024M TCL performance Use this feature to enable the CAS Latency tCL to increase memory performance The options are Disabled and Enable...

Страница 73: ...E Power Down Clock enable CKE Power Down controls the low power down for the memory The options are Disabled Active Power Down and Precharge Power Down Memory Thermal Throttling Memory thermal throttl...

Страница 74: ...led and Disabled Port 60 64 Emulation Select Enabled for I O port 60h 64h emulation support which in turn will provide complete legacy USB keyboard support for the operating systems that do not suppor...

Страница 75: ...ill be available for configuration SATA 0 LPM Use this feature to enable or disable Aggressive Link Power Management The options are Enabled and Disabled SATA 0 SGPIO LED Use this feature to select SA...

Страница 76: ...abled SATA 1 ALPM will be available for configuration SATA 1 ALPM Use this feature to enable or disable Aggressive Link Power Management The options are Enabled and Disabled SATA 1 SGPIO LED Use this...

Страница 77: ...4G Decoding Select Enabled to decode a PCI device that supports 64 bit in the space above 4G Address The options are Disabled and Enabled SR IOV Support Select Enabled for Single Root IO Virtualizati...

Страница 78: ...he options are Disabled Auto and Force L0s Warning Enabling ASPM support may cause some PCI E devices to fail ARI Forwarding Select Enabled to lift a traditional Device Number restriction when turning...

Страница 79: ...disabled it will not create the Ipv6 PXE Boot option The options are Disabled and Enabled PXE boot wait time Use this feature to select the wait time to press the ESC key to abort the PXE boot The def...

Страница 80: ...add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are VT100 VT100...

Страница 81: ...OM1 Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled COM1 Resolution 100x31 Select Enabled...

Страница 82: ...f 1 s in data bits is even Select Odd if the parity bit is set to 0 and the number of 1 s in data bits is odd Select None if you do not want to send a parity bit with your data bits in transmission Se...

Страница 83: ...re allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Mgmt Port The feature selects a serial port in...

Страница 84: ...covery and health monitoring The options are Disabled and Enabled Headless Support Select Enabled for the system to function without a keyboard mouse or monitor The options are Disabled and Enabled Tr...

Страница 85: ...e Status TPM Owner Status The features from here to Device Select on the next page are displayed if a TPM 2 0 module is detected TPM20 Device Found Vendor IFX Firmware Version 5 51 Configuration Secur...

Страница 86: ...tem to disable or enable storage hierarchy for cryptographic protection The options are Disabled and Enabled Endorsement Hierarchy Use this item to disable or enable endorsement hierarchy for privacy...

Страница 87: ...work Connection 0C C4 7A XX XX XX Intel Ethernet Connection X553 1GbE 0C C4 7A XX XX XX Intel Ethernet Connection X553 1GbE 0C C4 7A XX XX XX Intel Ethernet Connection X553 1GbE 0C C4 7A XX XX XX Inte...

Страница 88: ...ture displays the network adapter chipset name PCI Device ID This feature displays the device ID number PCI Address This feature displays the PCI address for this computer PCI addresses are three two...

Страница 89: ...The options are Disabled and Enabled Memory ELog Support Use this feature to enable or disable memory error logging suport The options are Disabled and Enabled Error Threshold Use this feature to mod...

Страница 90: ...rd Settings Log System Boot Event Select Enabled to log system boot events The options are Enabled and Disabled MECI Multiple Event Count Increment Enter the increment value for the multiple event cou...

Страница 91: ...in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings Erase SEL Select...

Страница 92: ...No and Yes If the feature above is set to Yes Configuration Address Source and VLAN will become available for configuration Configuration Address Source Use this feature to select the source of the IP...

Страница 93: ...N function The options are Disable and Enable IPMI Extended Instruction Use this feature to enable IPMI extended function support The options are Enabled and Disabled When Disabled the system powers o...

Страница 94: ...the BIOS Setup utility The options are Setup and Always Administrator Password Use this feature to set the administrator password which is required to enter the BIOS setup utility The length of the pa...

Страница 95: ...and No Restore Factory Keys Select Yes to restore all factory keys to the default settings The options are Yes and No Key Management This submenu allows the user to configure the following Key Manage...

Страница 96: ...lete the KEK from NVRAM The options are Yes and No Authorized Signatures Save to File Select Yes to save the db to a storage device Set New Select Yes to load the db from the manufacturer s defaults S...

Страница 97: ...Select No to load the dbt from a file The options are Yes and No Append Select Yes to add the dbt from the manufacturer s defaults list to the existing dbt Select No to load the dbt from a file The op...

Страница 98: ...CY UEFI and DUAL Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system boots from Press Enter on each entry from top to bottom to select devices LEGACY UEFI...

Страница 99: ...t order of detected devices The options are the list of detected boot device s and Disable UEFI Network Drive BBS Priorities Boot Option This feature sets the system boot order of detected devices The...

Страница 100: ...and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Discard Changes and Exit from the Exit menu and press...

Страница 101: ...o retrieve user defined settings that were saved previously Boot Override Other boot options are listed in this section The system will boot to the selected boot option UEFI Built in EFI Shell UEFI PX...

Страница 102: ...up If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The table below lists som...

Страница 103: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...

Страница 104: ...O files insert the disk into the DVD drive on your system and the display shown in Figure B 1 should appear Another option is to go to the Supermicro website at http www supermicro com products Find t...

Страница 105: ...sumption and fan speed and provides alerts via email or the Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize...

Страница 106: ...efore installing or configuring components These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Battery Handling Warnung Bei Einsetzen einer...

Страница 107: ...evaar indien de batterij verkeerd vervangen wordt Vervang de batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fab...

Страница 108: ...lamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp...

Страница 109: ...Image A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the...

Страница 110: ...a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image file into the disc Root Directory of a USB device or a writeable CD DVD Note If you cann...

Страница 111: ...u want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 5 When the screen as shown above displays use the arrow keys to select the item Proceed with f...

Страница 112: ...age into a USB flash drive 8 Press Del continuously to enter the BIOS setup utility Set the item Boot Option 1 to UEFI AP UEFI Built in EFI Shell Press F4 to save the settings and exit the BIOS setup...

Страница 113: ...o not interrupt this process until the BIOS flashing is complete 10 The screen below indicates that the BIOS update process is complete Unplug the AC power cable from the power supply clear the CMOS a...

Страница 114: ...ur due to a software tool issue see image below or an unexpected power outage during BIOS updates BIOS Boot Block Corruption Occurrence When a BIOS boot block is corrupted due to an unexpected power o...

Страница 115: ...per JBR1 1 Power down the system 2 Close pins 2 3 on jumper JBR1 and power on the system 3 Follow the BIOS recovery SOP listed in the previous chapter Appendix D 4 After completing the steps above pow...