background image

USER’S MANUAL 

Revision 1.0c

A+ Server

AS -4023S-TRT

Содержание A+ AS-4023S-TRT

Страница 1: ...USER S MANUAL Revision 1 0c A Server AS 4023S TRT...

Страница 2: ...an industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful...

Страница 3: ...als Product drivers and utilities www supermicro com wftp driver AMD SP3 Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our...

Страница 4: ...ns 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Ground 19 2 3 Installing the System into a...

Страница 5: ...rive Bay 40 Adding a DVD ROM Drive 40 Mobile Rack Optional Storage Module 40 System Cooling 43 Fan Failure 43 Air Shroud 44 3 5 Power Supply 45 Power Supply Failure 45 Chapter 4 Motherboard Connection...

Страница 6: ...ve Exit 90 6 9 Updating BIOS with IPMI 91 Chapter 7 BIOS EPYC 7002 Series 7 1 Introduction 93 Starting the Setup Utility 93 7 2 Main Setup 94 7 3 Advanced 96 7 4 IPMI 113 7 5 Event Logs 116 7 6 Securi...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 8: ...appears damaged please file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area...

Страница 9: ...emory Supports up to 2TB of ECC DDR4 2666 or 4TB of ECC DDR4 3200 RDIMM LRDIMM 3DS NVDIMM memory in 16 slots board revision 2 x required Chipset AMD SoC System on Chip Expansion Slots Two PCI E 3 0 x1...

Страница 10: ...5 NIC2 LED Indicates network activity on the LAN2 port when flashing 6 NIC1 LED Indicates network activity on the LAN1 port when flashing 7 System Overheat LED Indicates a system overheat condition wh...

Страница 11: ...optional HDD or DVD ROM drive 3 3 5 Hard Drive Bays Eight hot swap HDD bays behind locking bezel 4 Feet Removable feet when using system in a 4U rackmount configuration Figure 1 2 Chassis Front View F...

Страница 12: ...ancy 2 I O Backpanel Rear I O ports see Section 4 3 3 Fan 8 cm exhaust fan 4 Expansion Card Slots Slots for seven standard size add on cards 5 Feet Removable feet when using system in a 4U rackmount c...

Страница 13: ...0 3 SATA DOM POWER SATA DOM POWER CPU2 SLOT1 PCI E 3 0 X8 CPU1 SLOT2 PCI E 3 0 X16 CPU1 SLOT3 PCI E 3 0 X8 CPU1 SLOT4 PCI E 3 0 X16 PWR I2C ALWAYS POPULATE DIMMx1 FIRST ALWAYS POPULATE DIMMx1 FIRST AL...

Страница 14: ...ers P2 SATA0 P2 SATA1 SATA 3 0 Ports for SATA DOM with integrated power CPU1 SATA0 3 CPU2 SATA0 3 Connectors for SATA0 3 use iPass breakout cable 4 ports each JF1 Front Control Panel Header JL1 Chassi...

Страница 15: ...ector Description P1 DIMMA1 P1 DIMMH1 DIMM slots for CPU1 P2 DIMMA1 P2 DIMMH1 DIMM slots for CPU2 CPU2 SLOT 1 x8 PCI E 3 0 Slot via CPU2 CPU1 SLOT 2 SLOT 4 x16 PCI E 3 0 Slot via CPU1 CPU1 SLOT 3 SLOT...

Страница 16: ...PCIe x16 PCIe3 0_x16 8 0GT s Slot 5 PCIe x8 PCIe3 0_x8 8 0GT s PCIe3 0_x8 8 0GT s PCIe3 0_x16 8 0GT s Rear USB 3 0 x 2 P1_DIMMA AMD P1_DIMMC P1_DIMMD P1_DIMME P1_DIMMG P1_DIMMH P1_DIMMF P1_DIMMB 2667...

Страница 17: ...kmount hardware needed to install it into the rack Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust fr...

Страница 18: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 19: ...than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure t...

Страница 20: ...came with the rack unit you are using Identifying the Sections of the Rack Rails The optional rackmount kit includes two rack rail assemblies Each of these assemblies consist of three sections an inne...

Страница 21: ...off Then unscrew the four feet and remove them from the chassis see Figure 2 2 You can now attach rack rails to the top and bottom now the sides of the chassis First add the rack handles Then position...

Страница 22: ...recautions in Section 2 3 Position the fixed rack rail sliding rail guide assemblies at the desired location in the rack keeping the sliding rail guide facing the inside of the rack Screw the assembly...

Страница 23: ...have two brackets in the rack mount kit Install these first keeping in mind that they are left right specific marked with L and R Then line up the rear of the chassis rails with the front of the rack...

Страница 24: ...a rack rotate the module that contains the control panel and the three drive trays 1 in Figure 2 5 90 degrees Note that two of the 5 25 drives may be replaced by a mobile rack containing eight 2 5 st...

Страница 25: ...release lever to unlock the module Module Release Lever Control Panel Drive Module in Rack Mount Orientation 3 4 Grasp the edges of the module and pull it from the chassis 5 Rotate the module 90 degr...

Страница 26: ...he power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the power supply module s 3 2 Accessin...

Страница 27: ...should be off as described in Section 3 1 before installing the processors When handling the processor package avoid placing direct pressure on the label area of the CPU or socket For the processor he...

Страница 28: ...w the screws holding down the force frame in the sequence of 3 2 1 The screws are numbered on the force frame next to each screw hole Screw 1 Screw 2 Screw 3 Force Frame 2 The spring loaded force fram...

Страница 29: ...rame lift it to a position so you can do the next step of removing the external cap Note The rail frame is spring loaded so keep a secure grip on it as you lift it so it does not snap up Rail Frame Pn...

Страница 30: ...y inserted into the CPU socket before closing the rail frame plate If it doesn t close properly do not force it as it may damage your CPU Instead open the rail frame plate again and double check that...

Страница 31: ...he rail frame and hold it in place until it is seated in the socket housing Note that the force frame is spring loaded and has to be held in place before it is secured Important Use a torque screwdriv...

Страница 32: ...frame and the CPU package 11 After the force frame is secured and the CPU package is in place now you must install the heatsink to the frame Lower the heatsink down till it rests securely over the fou...

Страница 33: ...age by reversing the installation procedure 2 Clean the thermal grease left by the heatsink on the CPU package lid to limit the risk of it contaminating the CPU package land pads or contacts in the so...

Страница 34: ...les to prevent any possible damage Memory Support The H11DSi NT 2 TB of ECC DDR4 2666 MHz speed 4TB of ECC DDR4 3200 MHz speed board reversion 2 x required RDIMM LRDIMM 3DS NVDIMM memory in 16 slots R...

Страница 35: ...1 Y A K 3 2 1 4 3 2 1 4 3 2 1 4 1 5 A C 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 4 1 4 1 4 1 6 1 5 4 8 1 5 4 8 1 1 13 12 24 A48 1 LEDM1 S N LABEL CPU1 SATA0 3 CPU2 SATA0 3 SATA DOM POWER SATA DOM POWER CPU2 S...

Страница 36: ...b Insert this end first then follow with the other end making sure the receptive point and the key are aligned 5 With one end of the DIMM secure into the notch catch press the opposite end with the le...

Страница 37: ...ot bracket 4 Pull the release tab upward 5 Remove the screw holding the bracket in place and pull the bracket from the chassis 6 Install your PCI card or other add on card into the PCI slot bracket an...

Страница 38: ...moving power from the system as described in Section 3 1 and remove the side cover as described in section 3 2 1 Push aside the small clamp that covers the edge of the battery When the battery is rele...

Страница 39: ...side of the cover about inch only Remove by pushing on the open side of the cover to remove it from the chassis do not try to swing or pull it straight out after opening the left side The drives are m...

Страница 40: ...f remove the two or four screws that secure the drive carrier to the chassis one side only then push the entire empty drive carrier out from the back Adding a DVD ROM Drive 1 Remove the guide plates o...

Страница 41: ...e drive tray rails 3 Install a drive tray rail onto each side of the mobile rack Make sure the arrow on the rail points toward the front of the chassis 4 Slide the mobile rack into the chassis 5 Conne...

Страница 42: ...down to rotate the mobile rack 1 Begin by removing power from the system as described in Section 3 1 and remove the side cover as described in section 3 2 2 Disconnect any cables from the back of the...

Страница 43: ...ontinuously The chassis fans and the exhaust fans are hot swappable and can be replaced without powering down the system Replacing Chassis Cooling Fans 1 Begin by removing the side cover as described...

Страница 44: ...it the air shroud should always be in place when the system is operating please follow this procedure Removing the Air Shroud 1 Begin by depressing the tabs at the front and rear of the shroud to unl...

Страница 45: ...wer supply modules allows you to replace the failed module without powering down the system Replacing the Power Supply You do not need to shut down the system to replace a power supply module The redu...

Страница 46: ...24 pin Primary ATX Power JPWR3 8 pin Processor Power JPWR1 JPWR2 Main ATX Power Connector JPWR1 is the 24 pin ATX main power supply connector This primary power supply connector meets the ATX SSI EPS...

Страница 47: ...in CPU Power Connectors JPWR2 and JPWR3 are the 8 pin 12V DC power input for the CPU or alternative single power source for a special enclosure when the 24 pin ATX power is not in use Refer to the tab...

Страница 48: ...p www supermicro com manuals other TPM pdf Trusted Platform Module Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 Key 5 LRESET 6 5V 7 LAD3 8 LAD2 9 3 3V 10 LAD1 11 LAD0 1...

Страница 49: ...SPI_MOSI 8 9 3 3V Stdby 10 SPI_IRQ TPM Header The JTPM1 header is used to connect a Trusted Platform Module TPM Port 80 which is available from a third party vendor A TPM Port 80 connector is a secur...

Страница 50: ...r Fail LED Ground Ground 2 1 20 19 Figure 4 1 JF1 Control Panel Pins Reset Button Pin Definitions JF1 Pins Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pins Definition 1 Signal 2 Groun...

Страница 51: ...s a system overheat or the internal fan s have failed UID LED Indicator A Unit Identifier UID switch and UID LED are located on the I O backpanel one UID LED indicator header is located on JF1 The rea...

Страница 52: ...nnection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 N...

Страница 53: ...e I O back panel This port accepts an RJ45 type cable 1 5 4 3 2 6 7 8 VGA Port A video VGA port is located next to LAN Port 2 on the I O back panel Use this to connect to a to a monitor that supports...

Страница 54: ...header is located on JF1 The rear UID LED is located next to the UID switch The front UID LED is located on pins 7 8 on the front control panel JF1 When you press the UID switch both rear and front UI...

Страница 55: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 56: ...s 2 3 will generate a non maskable interrupt signal for the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to...

Страница 57: ...n Green Blinking BMC Normal Onboard Power LED The Onboard Power LED is located at LED3 on the motherboard When this LED is lit it means power is present on the motherboard In suspend mode this LED wil...

Страница 58: ...tallation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive or the IPMI KVM console 2 Go to the Supermicro web page for your motherboard and click on Downl...

Страница 59: ...he bottom left corner Figure 5 2 Load Driver Link To load the driver browse the USB flash drive for the proper driver files Choose the SATA sSATA AHCI driver indicated then choose the storage drive on...

Страница 60: ...Figure 5 3 should appear Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard here where you may download individual driver...

Страница 61: ...nagement Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP...

Страница 62: ...ch as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot...

Страница 63: ...d time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY f...

Страница 64: ...S TRT User s Manual 64 CPLD Version This item displays the version of the CPLD firmware used in the system Memory Information Total Memory This item displays the total size of memory available in the...

Страница 65: ...the submenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enab...

Страница 66: ...cally reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Ti...

Страница 67: ...d for TPM Trusted Platform Module support to enhance data integrity and network security Please reboot the system for a change on this setting to take effect The options are Disable and Enable TPM Sta...

Страница 68: ...cores a power cycle is required in order for the future selections to take effect Options include TWO 1 1 Two 2 0 Three 3 0 Four 2 2 Four 4 0 Six 3 3 and Auto If unsure leave this to Auto L1 Stream HW...

Страница 69: ...erent memory clock speed Options include Auto and speed settings from 1333Mhz to 2666Mhz Memory Interleaving This setting controls fabric level memory interleaving Note that the channel die and socket...

Страница 70: ...nformation will display Super IO Chip AST2500 Serial Port 1 Configuration Serial Port Select Enabled to enable the selected onboard serial port The options are Disabled and Enabled Device Settings Thi...

Страница 71: ...se the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Character Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one...

Страница 72: ...NSI VT100 terminals The options are Disabled and Enabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabl...

Страница 73: ...send a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your dat...

Страница 74: ...he Legacy Console Redirection is enabled for legacy OS systems Default option for this system is Always Enable Serial Port for Out of Band Management Windows Emergency Management Services EMS Console...

Страница 75: ...nding data when the receiving buffer is empty The options are None Hardware RTS CTS and Software Xon Xoff Data Bits Parity Stop Bits PCIe PCI PnP Configuration This menu provides PCIe PCI PnP configur...

Страница 76: ...PCI PCIX PCIe Slot OPROM option Options include Disabled Legacy or EFI CPU1 Slot 2 PCI E x16 OPROM This setting enables or disables the listed PCI PCIX PCIe Slot OPROM option Options include Disabled...

Страница 77: ...This setting selects which onboard video firmware type to be selected Options include Disabled Legacy and EFI CPU2 Slot 1 PCI E 3 0 x8 Bifurcation This setting selects the bifurcation configuration fo...

Страница 78: ...be available Ipv6 HTTP Support This setting allows you to Enable or Disable IPv6 HTTP boot support If disabled IPv6 HTTP boot support will not be available PXE Boot Wait Time This setting allows you...

Страница 79: ...SATA0 CPU1 SATA7 iSCSI Configuration iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered in...

Страница 80: ...erface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status Baseboard Management Controller This item indicates the status of the IPMI fir...

Страница 81: ...t all IP MAC address changes at the next system boot The options are No and Yes Configure IPV4 Support This section displays static configuration features for IPV4 support IPMI LAN Selection This item...

Страница 82: ...e Configure IPV6 Support This section displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address S...

Страница 83: ...ure SMBIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Erasi...

Страница 84: ...MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item i...

Страница 85: ...Password is erased the User Password will be cleared as well User Password Press Enter to create a new or change an existing User password Password Check Select Setup for the system to check for a pa...

Страница 86: ...secure keys set by the manufacturer The options are Yes and No Enroll EFI Image This allows the image to run in Secure Boot Mode and enroll SHA256 hash of the binary into an Authorized Signature Data...

Страница 87: ...s to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Key Select Yes to load the DBT from...

Страница 88: ...boot to an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities Section This option prioritizes the order of bootable devices that the system to boot from Press Enter on...

Страница 89: ...Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Order 1 Hard Disk Drive BBS Priorities This feature allows the user to specify which h...

Страница 90: ...eboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset the system after saving the changes Save Changes After completi...

Страница 91: ...ts from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved previously Boot Override Section Listed on this section are other boot options for the system i...

Страница 92: ...button The message Uploading image checking BIOS information Please wait This may take a while appears 6 Please make sure the following three checkboxes as shown below are unchecked and verify the BI...

Страница 93: ...used such as F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options...

Страница 94: ...m Time Use this option to change the system date and time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move betw...

Страница 95: ...ys the date when the version of the BIOS firmware used in the system was built CPLD Version This item displays the version of the CPLD firmware used in the system Memory Information Total Memory This...

Страница 96: ...e submenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled...

Страница 97: ...atically reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog...

Страница 98: ...ET can produce periodic interrupts and is used to synchronize multimedia streams providing smooth playback and reducing the need to use other timestamp calculations The options are Disabled and Enable...

Страница 99: ...Settings The options are Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port Console Red...

Страница 100: ...The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower device...

Страница 101: ...required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are...

Страница 102: ...s are VT100 LINUX XTERMR6 SC0 ESCN and VT400 Legacy Console Redirection Legacy Console Redirection Settings Redirection COM Port For this setting select a COM port to display redirection of Legacy OS...

Страница 103: ...the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control fo...

Страница 104: ...d Auto Core Control This sets the number of cores to be used by your system Once this option has been used to remove any cores a power cycle is required in order for the future selections to take effe...

Страница 105: ...ls about the detected CPUs on the motherboard such as CPU Version Number of Cores Running Clock speed Processor Family Processor Model Microcode Patch Level L1 Instruction Cache Size Method L1 Data Ca...

Страница 106: ...include Manual and Auto Memory Configuration Memory Clock This setting allows you to select different memory clock speed The options include Auto and speed settings Memory Interleaving This setting c...

Страница 107: ...PCI PnP Configuration This menu provides PCIe PCI PnP configuration settings and information PCI Bus Driver Version Above 4G Decoding This setting Enables or Disables 64 bit capable devices ability to...

Страница 108: ...les the listed PCI PCIX PCIe Slot OPROM option Options include Disabled Legacy or EFI CPU1 Slot 3 PCI E x8 OPROM This setting enables or disables the listed PCI PCIX PCIe Slot OPROM option Options inc...

Страница 109: ...tion This setting selects the bifurcation configuration for this particular PCI E slot The options Auto and x4x4 CPU1 Slot 2 PCI E 3 0 x16 Bifurcation This setting selects the bifurcation configuratio...

Страница 110: ...d PXE boot wait time This setting allows you to set in a number field the wait time to press ESC to abort the PXE boot Default is 0 Media detect count This setting allows you set in a number field the...

Страница 111: ...ons include Disabled and Enabled SATA Information This item displays information on the detected SATA devices connected and are detected HTTP BOOT Configuration HTTP Boot One Time When the HTTP boot o...

Страница 112: ...ration This submenu allows the user to configure Transport Layer Security TLS settings Server CA Configuration Enroll Certification Enroll Certification using File Use this feature to enroll certifica...

Страница 113: ...Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status Baseboard Management Controller This item indicates the status of the IPMI...

Страница 114: ...l IP MAC address changes at the next system boot The options are No and Yes Configure IPV4 Support This section displays static configuration features for IPV4 support IPMI LAN Selection This item dis...

Страница 115: ...ptions are Disabled and Enable Configure IPV6 Support This section displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Dis...

Страница 116: ...e SMBIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing...

Страница 117: ...led MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This ite...

Страница 118: ...assword is erased the User Password will be cleared as well User Password Press Enter to create a new or change an existing User password Password Check Select Setup for the system to check for a pass...

Страница 119: ...oot keys after the platform reset and while the system is in Setup mode The options include Disabled and Enabled Restore Factory Keys Select Yes to install all default secure keys set by the manufactu...

Страница 120: ...to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Update Select Yes to load the DBT from the ma...

Страница 121: ...I OS after the boot failed from the legacy boot order The options include Disabled and Enabled FIXED BOOT ORDER Priorities Section This option prioritizes the order of bootable devices that the system...

Страница 122: ...to specify which UEFI devices are boot devices Boot Option 1 Hard Disk Drive BBS Priorities This feature allows the user to specify which hard disk drive devices are boot devices NETWORK Drive BBS Pri...

Страница 123: ...d reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset the system after saving the changes Save Changes After compl...

Страница 124: ...aults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved previously Boot Override Section Listed on this section are other boot options for the syste...

Страница 125: ...IOS button The message Uploading image checking BIOS information Please wait This may take a while appears 6 Please make sure the following three checkboxes as shown below are unchecked and verify the...

Страница 126: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 127: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 128: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Страница 129: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 130: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 131: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 132: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 133: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 134: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 135: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 136: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 137: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 138: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 139: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 140: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 141: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 142: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 143: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 144: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...

Страница 145: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 146: ...D SoC System on Chip controller Drive Bays Eight 3 5 hot swap drive bays for SATA3 with optional SAS3 NVMe support PCI Expansion Slots Two PCI E 3 0 x16 slots Three PCI E 3 0 x8 slots Two internal NVM...

Страница 147: ...and GB17625 1 2012 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Di...

Страница 148: ...OS loader which is stored in the add on card to boot the system The UEFI offers clean hands off control to a computer system at bootup C 2 Recovering the UEFI BIOS Image A UEFI BIOS flash chip consist...

Страница 149: ...ur driver disk visit our website at www supermicro com to download the correct BIOS image into a USB flash device and rename it SUPER ROM 2 While the system is turned off insert the USB device that co...

Страница 150: ...GUI or SUM Please refer to these SUPERMICRO software related videos Activate OOB license https www youtube com watch v V4spX_DOV7I SUPERMICO BIOS Update https www youtube com watch v S8z6iOEHGwY If th...

Отзывы: