USER’S MANUAL 

Revision 1.0b

A+ Server

AS -2013S-C0R

Содержание A+ AS-2013S-C0R

Страница 1: ...USER S MANUAL Revision 1 0b A Server AS 2013S C0R...

Страница 2: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...

Страница 3: ...drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities www supermicro com wftp driver AMD SP3 Product...

Страница 4: ...sing a Setup Location 17 Rack Precautions 17 Server Precautions 18 Rack Mounting Considerations 18 Ambient Operating Temperature 18 Airflow 18 Mechanical Loading 18 Circuit Overloading 19 Reliable Gro...

Страница 5: ...tate Drive 39 Installing an Optional Fixed Hard Drive 40 System Cooling 41 Installing Fans 41 Air Shroud 42 Power Supply 42 Power Supply Failure 42 Chapter 4 Motherboard Connections 4 1 Power Connecti...

Страница 6: ...etup 65 6 3 Advanced 67 6 4 IPMI 82 6 5 Event Logs 85 6 6 Security 87 6 7 Boot 90 6 8 Save Exit 92 6 9 BIOS Update Using IPMI 94 Appendix A Standardized Warning Statements for AC Systems Appendix B Sy...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 8: ...ion for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated...

Страница 9: ...rd revision 2 x Socket Type Socket SP3 Memory Supports up to 1TB Registered ECC DDR4 2666MHz SDRAM in 8 DIMMs 2TB Registered ECC DDR4 3200MHz SDRAM in 8 DIMMs board revision 2 x required Chipset AMD S...

Страница 10: ...oot the system 8 Power Button Main power button to apply or remove power from the system Information LED Status Description Continuously on and red An overheat condition has occurred This may be cause...

Страница 11: ...Bays Optional drive bays for DVD ROM or extra hard drives 3 Control Panel Front control panel with LEDs and buttons see preceding page 4 Rack Ear Brackets Secures the server chassis to the rack Figure...

Страница 12: ...height half length PCI slots with pre installed riser cards 5 Rack Ear Brackets Secures the server chassis to the rack Figure 1 3 Chassis Rear View Rear Features The illustration below shows the feat...

Страница 13: ...JI2C_FP1 JNCSI1 JPI2C1 SP1 JLAN1 JLAN2 LEDSAS A C JUSB3 1 19 10 11 JTPM1 JSD2 1 JSD1 1 3 JVRM1 JPL2 JPG1 JPB1 3 JWD1 JBR2 JPL1 JPSAS1 JPS1 JCOM1 JF1 1 FAN5 FAN4 FAN3 FAN2 FAN1 FANA 1 JOH1 BT2 TP3 JVGA...

Страница 14: ...M 2 active LED Green M 2 PCIe port active LEDSAS SAS port active LED Green SAS port active Connector Description Battery BT1 Onboard CMOS battery JNCSI1 NCSI header COM 1 Rear panel COM port 1 FAN 1 5...

Страница 15: ...TX auxiliary power supply connector JD1 Front panel external speaker header PWRI2C Power supply SMBus I2C header LAN1 LAN2 Back panel LAN1 LAN2 connectors VGA Back panel VGA port SP1 Onboard speaker N...

Страница 16: ...TA DOM CPU PCIE P3 0 7 CPU USB0 0_1 AMD SP3 CPU PCIE P0 8 CPU PCIE P0 2 PCIE X16 SATA DOM CPU PCIE P1 15 0 SLOT 2 M 2 PCIE X8 SLOT1 0 3 7 8 15 PCIE X8 SLOT3 3 4 5 6 7 SATA2 7 NVME1 NVME2 OR OR mini SA...

Страница 17: ...Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...

Страница 18: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 19: ...than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure t...

Страница 20: ...the Inner Rails The SC825TQC chassis includes a set of inner rails in two sections inner rails and inner rail extensions Inner rail extensions are attached to the inner rails to mount the chassis in t...

Страница 21: ...you decide not to use a server rack The inner rail extension is attached to the inner rail to mount the chassis in the rack Installing the Inner Rails 1 Place the inner rail extensions on the side of...

Страница 22: ...ach to the rack and hold the chassis in place The outer rails for the SC825 chassis extend between 30 inches and 33 inches Installing the Outer Rails to the Rack 1 Secure the back end of the outer rai...

Страница 23: ...outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked...

Страница 24: ...onnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove the AC power cords from all power supply modules 3 Disconnect the power cord s from the p...

Страница 25: ...ing or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an AMD certi...

Страница 26: ...holding down Force Frame in the sequence of 3 2 1 The screws are numbered on the force frame next to each screw hole Screw 1 Screw 2 Screw 3 Force Frame 2 The spring loaded force frame will raise up...

Страница 27: ...ip of the rail frame lift it to a position so you can do the next step of removing the external cap Note The rail frame is spring loaded so keep a secure grip on it as you lift it so it does not snap...

Страница 28: ...sembly from its shipping tray and while gripping the handle align the flanges of the carrier frame onto the rails of the rail frame so its pins will be at the bottom when the rail frame is lowered lat...

Страница 29: ...rail frame till it securely rests in upright position Then remove the PnP cover cap from the CPU socket below Grip the two lift tabs marked Remove at the middle of the cap and pull vertically upwards...

Страница 30: ...ore it is secured Important Use a torque screwdriver set it at 16 1 kgf cm 14 0 lbf in with a Torx T20 screw head bit to prevent damage to the CPU 10 Place and re screw the screws in the order 1 2 3 t...

Страница 31: ...rew holes on CPU package on the socket frame 12 Using a diagonal pattern and a Torx T20 driver tighten the four heatsink screws evenly to 16 1 kgf cm 14 0 lbf in of torque in a clockwise fashion till...

Страница 32: ...ore proceeding 6 Reverse the procedure for installing the force frame onto the socket unscrewing the plate in the 3 2 1 screw order and lift the force frame to the vertical position 7 Lift the rail fr...

Страница 33: ...additional memory information Populating RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS DDR4 Memory Modules with 7001 Processor Type DIMM Population Maximum DIMM Capacity GB Maximum Frequency MHz 1 Channel 4 Chan...

Страница 34: ...0 2R or 2DR 64GB 512GB 3200 3DS LRDIMM 2S2R 128GB 1TB 3200 2S4R 256GB 2TB 3200 3DS RDIMM 2S2R 128GB 1TB 3200 2S4R 2568GB 2TB 3200 DIMM Population Guide with AMD 7002 Processor CPU Channel D1 C1 B1 A1...

Страница 35: ...A7 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 1 I SATA0 MH7 MH6 MH2 JNVME1 PRESS FIT JNVME0 PRESS FIT JSAS1 PRESS FIT DS1 CPU 1 2 Enable SAS HDD Status Support Default 2 3 Disable SAS HDD Status Support...

Страница 36: ...memory slot 4 Align the notches on both ends of the module against the receptive points on the ends of the slot 5 Press both ends of the module straight down into the slot until the module snaps into...

Страница 37: ...in section 3 2 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2 To insert a new battery slide one edge under the lip of the ho...

Страница 38: ...hassis These carriers also help promote proper airflow for the drive bays For this reason even empty carriers without drives installed must remain in the chassis Removing a Hot Swap Drive Carrier 1 Pu...

Страница 39: ...ircuit board side facing down so that the mounting holes align with those in the carrier 2 Secure the drive to the carrier with screws as illustrated below 3 Insert the drive carrier back into its bay...

Страница 40: ...JPI2C1 SP1 JLAN1 JLAN2 LEDSAS A C JUSB3 1 19 10 11 JTPM1 JSD2 1 JSD1 1 3 JVRM1 JPL2 JPG1 JPB1 3 JWD1 JBR2 JPL1 JPSAS1 JPS1 JCOM1 JF1 1 FAN5 FAN4 FAN3 FAN2 FAN1 FANA 1 JOH1 BT2 TP3 JVGA1 LED1 LE1 A LE...

Страница 41: ...mmy drive and the slot cover must be removed Removing the Dummy Drive or Hard Disk Drive 1 Begin by removing power from the system as described in section 3 1 and the chassis cover as described in sec...

Страница 42: ...pen the chassis while the power is running to determine which fan has failed Never run the server for an extended period of time with the chassis open 1 Begin by removing power from the system as desc...

Страница 43: ...ower Supply Failure If either of the two power supply modules fail the other module will take the full load and allow the system to continue operation without interruption The Power Fail LED will illu...

Страница 44: ...44 Chapter 3 Maintenance and Component Installation Figure 3 7 Replacing a Power Supply Module...

Страница 45: ...supply The wiring is included with the power supply 24 pin Primary ATX Power JPWR2 8 pin Processor Power JPWR1 JPW2 Main Power Supply Connector JPWR2 The primary power supply connector JPWR2 is an AT...

Страница 46: ...onnector Pin Definitions Pins Definition 1 through 4 Ground 5 through 8 12V Required Connection 12V 4 pin Auxilliary Power Connector JPW1 JPW1 is an 4 pin ATX power input to provide auxiliary power to...

Страница 47: ...to one of the SATA ports See the table below for pin definitions DOM Power Pin Definitions Pin Definition 1 5V 2 Ground 3 Ground L SAS Ports L SAS0 L SAS7 H11SSL NC H11SSL C Only The motherboard supp...

Страница 48: ...in Definition 1 LCLK 2 GND 3 LFRAME 4 Key 5 LRESET 6 N C 7 LAD3 8 LAD2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK optional 14 SMB_DAT optional 15 P3V3_STBY 16 SERIRQ 17 GND 18 LP_CLKRUN optional 19 LPC_...

Страница 49: ...B_PN3 5 USB_PP2 6 USB_PP3 7 Ground 8 Ground 9 Key 10 Ground Front Panel USB 3 0 Pin Definitions Pin Definition Pin Definition 1 VBUS 19 Power 2 Stda_SSRX 18 USB3_RN 3 Stda_SSRX 17 USB3_RP 4 GND 16 GNd...

Страница 50: ...erheat Fan Fail LED Status Status Definition Off Normal On Solid Overheat On Blinking Fan Failure Standby Power Header JSTBY1 The Standby Power header is located at JSTBY1 on the motherboard Standby P...

Страница 51: ...xternal speaker to pins 6 7 See the table below for pin definitions Speaker Connector Pin Definitions Pin Setting Definition Pins 1 2 Power LED Pins 6 7 External Speaker Power SMB Header PWRI2C Power...

Страница 52: ...OM POWER SATA DOM POWER JF1 UID LED JVRM1 2 3 DISABLE 1 2 ENABLE OH RST PWR ON FAIL PS NIC LED UID 2 NIC 1 LED PWR LED HDD NMI X L SAS0 7 BATTERY JBT1 CMOS CLEAR TPM PORT80 PWRI2C JL1 CHASSIS INTRUSIO...

Страница 53: ...turn off the LED indicators The UID Indicator provides easy identification of a system that may be in need of service Note UID can also be triggered via IPMI on the serverboard For more information on...

Страница 54: ...E6 JPCIE4 I SATA6 7 I SATA7 I SATA5 I SATA4 I SATA3 I SATA2 I SATA1 1 I SATA0 MH7 MH6 MH2 JNVME1 PRESS FIT JNVME0 PRESS FIT JSAS1 PRESS FIT DS1 CPU 1 2 Enable SAS HDD Status Support Default 2 3 Disabl...

Страница 55: ...ardware reset switch on the computer case to reset the system Refer to the table below for pin definitions Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Fan Fail and UID LED Connect...

Страница 56: ...LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a cable to pin 14 to show hard drive activity status Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pin...

Страница 57: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 58: ...sable JPG1 JPG1 allows you to enable or disable the VGA port The default position is on pins 1 and 2 to enable VGA See the table below for jumper settings VGA Enable Disable Jumper Settings JPG1 Jumpe...

Страница 59: ...nk LED Connection Link Speed Indicator LED Color Definition None 10 Mb s Green 100 Mb s Amber 1 Gb s Activity LED LED Color State Definition None No Connection Yellow Solid On Link Yellow Flashing Act...

Страница 60: ...m is turned off or any one of the system power rails fails this LED will turn off Turn off the system and unplug the power cord before removing or installing any component s Onboard Power LED Indicato...

Страница 61: ...r website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a...

Страница 62: ...ad the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID cho...

Страница 63: ...ferred Another option is to go to the Supermicro website at www supermicro com Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk a...

Страница 64: ...ctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP...

Страница 65: ...Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be configured...

Страница 66: ...time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY for...

Страница 67: ...hapter 6 BIOS 67 CPLD Version This item displays the CPLD version of the BIOS ROM used in the system Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 68: ...ss the submenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select En...

Страница 69: ...reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer wi...

Страница 70: ...Enabled and Disabled Pending Operation This feature will schedule an operation for the the security device select TPM Clear to clear any pending operation The options are None and TPM Clear Platform H...

Страница 71: ...ove any cores a power cycle is required in order for the future selections to take effect Options include TWO 1 1 Two 2 0 Three 3 0 Four 2 2 Four 4 0 Six 3 3 and Auto If unsure leave this to Auto L1 S...

Страница 72: ...e the cTDP Control Options include Manual and Auto IOMMU Use this setting to enable disable IOMMU Options include Enabled Disabled and Auto ACS Enable This feature sets the option to enable or disable...

Страница 73: ...hey will display some details about the detected memory according to each CPU on the motherboard such as Detected Size per slot in MB Current Speed MT s ACPI Settings High Precision Event Timer The Hi...

Страница 74: ...automatically assign the base I O and IRQ address The options are Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ...

Страница 75: ...with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data pack...

Страница 76: ...nto one or more bytes The options are VT100 VT100 VT UTF8 and ANSI Bits per second Use this feature to set the transmission speed for a serial port used in Console Redirection Make sure that the same...

Страница 77: ...send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Disabled and Enabled Putty Ke...

Страница 78: ...minal emulation type for Console Redirection Select VT100 to use the ASCII character set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select V...

Страница 79: ...is sets an upper limit on Link Operational Speed by restricting the values advertised by the UPstream component in its training sequences When Auto is selected the HW initialized data will be used PCI...

Страница 80: ...or disables the listed PCI PCIX PCIe Slot OPROM option Options include Disabled Legacy or EFI M 2 PCI E x4 OPROM This setting enables or disables the listed M 2 PCI E OPROM option Options include Dis...

Страница 81: ...etting enables or disables DDR4 RCD Register Clock Driver Parity RDimmParEn The options are Enabled and Disabled DRAM Address Command Parity Retry This setting enables or disables DRAM Address Command...

Страница 82: ...ator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the proper settings for t...

Страница 83: ...IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status Baseboard Management Controller This item indicates the status of the IPMI firmware...

Страница 84: ...on features for IPV4 support IPMI LAN Selection This item displays the IPMI LAN setting The default setting is Failover IPMI Network Link Status This item displays the IPMI Network Link status The def...

Страница 85: ...ays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user to selec...

Страница 86: ...igure SMBIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Enabled and Disabled Era...

Страница 87: ...Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used...

Страница 88: ...or Password is erased the User Password will be cleared as well User Password Press Enter to create a new or change an existing User password Password Check Select Setup for the system to check for a...

Страница 89: ...cure keys set by the manufacturer The options are Yes and No Enroll EFI Image This allows the image to run in Secure Boot Mode and enroll SHA256 hash of the binary into an Authorized Signature Databas...

Страница 90: ...Yes to add the DBX from the manufacturer s defaults to the existing DBX Select No to load the DBX from a file The options are Yes and No Authorized TimeStamps Set New Key Select Yes to load the DBT fr...

Страница 91: ...o an EFI OS after the boot failed from the legacy boot order FIXED BOOT ORDER Priorities Section This option prioritizes the order of bootable devices that the system to boot from Press Enter on each...

Страница 92: ...I Application Boot Priorities This feature allows the user to specify which UEFI devices are boot devices UEFI Boot Order 1 NETWORK Drive BBS Priorities This feature allows the user to specify which U...

Страница 93: ...the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset the system after saving the changes Save Changes After completing the...

Страница 94: ...ave as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Default...

Страница 95: ...save it 2 Access the IPMI web interface Enter the IP address and log in The default username and password are ADMIN ADMIN For details on IPMI use the link above 3 Click the Maintenance tab then BIOS...

Страница 96: ...6 3 Start Upgrade Dialog Verify Date 6 In the Start Upgrade dialog make sure the three checkboxes are not checked and verify the date of the BIOS file you uploaded before proceeding 7 Click the Start...

Страница 97: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 98: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Страница 99: ...n dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan he...

Страница 100: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 101: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 102: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 103: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 104: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 105: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 106: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 107: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 108: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 109: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 110: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 111: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 112: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 113: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 114: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 115: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...

Страница 116: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 117: ...board Broadcom 3008 SAS controller Drive Bays Four hot swap 3 5 drive bays choice of SATA3 default or SAS3 with optional SAS card PCI Expansion Slots Three PCIe 3 0 x16 slots Three PCIe 3 0 x8 slots O...

Страница 118: ...11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Directive 2012 19 EU Perchlor...

Страница 119: ...he recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system pow...

Страница 120: ...le into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website at www supermicro com to download the BIOS package E...

Страница 121: ...own above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt th...

Страница 122: ...change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do no...

Страница 123: ...unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Pre...