Supermicro 5018D-FN4T Скачать руководство пользователя страница 109

Chapter 7: AMI BIOS

7-33

Setup Prompt Timeout

Use this item to indicate the length of time (the number of seconds) for the BIOS to 
wait before rebooting the system when the setup activation key is pressed. Enter the 

value of 65535 (0xFFFF) for the BIOS to wait indefinitely. The default setting is 

1

.

Boot Mode Select

Use this item to select the type of device that the system is going to boot from. The 
options are Legacy, UEFI, and 

Dual.

 The default setting is Dual.

Fixed Boot Order Priorities

This option prioritizes the order of bootable devices that the system to boot from. 
Press <Enter> on each entry from top to bottom to select devices.

• 

Boot Option #1

• 

Boot Option #2

• 

Boot Option #3

• 

Boot Option #4

• 

Boot Option #5

7-7   Boot Settings

Use this feature to configure Boot Settings:

Содержание 5018D-FN4T

Страница 1: ...USER S MANUAL Revision 1 0 SUPERSERVER 5018D FN4T...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...rienced technicians only Please refer to the server specifications page on our Web site for updates on supported memory processors and operating systems http www supermicro com Warnings Special attent...

Страница 4: ...1 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 2 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3...

Страница 5: ...your system 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Motherboard Setup 5 1 Handling the Motherboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Connecting Cables 5 2 Connecting Data Cables 5...

Страница 6: ...g an Expansion Card 6 7 6 6 Installing Optional System Fans 6 8 Checking the Chassis Airflow 6 9 6 7 Power Supply 6 9 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change...

Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 8: ...viii SUPERSERVER 5018D FN4T Manual Notes...

Страница 9: ...components are listed below One riser card RSC RR1U E16 and bracket for a PCI expansion card Cooling One 4 cm fan FAN 0065L4 Note For your system to work properly please follow the links below to down...

Страница 10: ...1540 eight Core 45W embedded processor SoC System on a Chip Memory The motherboard has four DDR4 288 pin slots that can support up to 128 GB of RDIMM or 64GB UDIMM memory It supports 2133 MHz memory...

Страница 11: ...0 3 SATA3 0 4 SATA3 0 5 SATA3 0 1 JPCIE1 PCIE 3 0 x16 M 2 connector PCIE 3 0 x4 or SATA 3 0 x1 DDR4 DIMM B1 DDR4 DIMM A2 A B A1 DDR4 DIMM A DDR4 DIMM B1 B SATA GEN 3 SATA DOM SWITCH SWITCH PCIE 3 0 x...

Страница 12: ...ives SATA DOM is also supported Control Panel The control panel provides system monitoring and power control LEDs indicate power on network activity hard disk drive activity and system overheat The co...

Страница 13: ...e Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Страница 14: ...1 6 SUPERSERVER 5018D FN4T User s Manual Notes...

Страница 15: ...for the rack unit that will hold your system It should be a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grou...

Страница 16: ...wo or more simultaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the ra...

Страница 17: ...ght have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must b...

Страница 18: ...ing screws into the thru holes in the front of the chassis and through the thru holes in the rack Figure 2 1 Installing the Chassis into a Rack Note Figures are for illustrative purposes only Always i...

Страница 19: ...Interface Chapter 3 System Interface 3 1 Overview The chassis includes a control panel on the front that includes power buttons and status monitoring lights and status lights for the power supply Figu...

Страница 20: ...ctivity on GLAN2 when flashing Information LED Alerts operator of several states as noted in the table below Information LED Status Description Continuously on and red An overheat condition has occure...

Страница 21: ...if the system overheats Overheat Temperature Setting Some backplanes allow the overheat temperature to be set at 45 50 or 55 degrees by changing a jumper setting For more information consult the backp...

Страница 22: ...er supply is on Solid Amber When illuminated indicates the power supply is plugged in and turned off or the system is off but in an abnormal state Blinking Amber When blinking this system power supply...

Страница 23: ...ertified technicians should attempt to install or configure components Read this chapter in its entirety before installing or configuring components in the Supermicro chassis Some warnings may not app...

Страница 24: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar e...

Страница 25: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaa...

Страница 26: ...e en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de branche...

Страница 27: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Страница 28: ...ift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing th...

Страница 29: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 30: ...rnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o u...

Страница 31: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 32: ...me or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een b...

Страница 33: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 34: ...e alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer toute tensi...

Страница 35: ...del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors d...

Страница 36: ...ectrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Back...

Страница 37: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 38: ...as leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l...

Страница 39: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 40: ...dapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle and...

Страница 41: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Страница 42: ...4 20 SUPERSERVER 5018D FN4T User s Manual Notes...

Страница 43: ...the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap desi...

Страница 44: ...ed as they were originally after reconnecting them make sure the red wires connect to the pin 1 locations The following data cables with their locations noted should be connected SATA drive data cable...

Страница 45: ...ard Setup 5 3 5 3 I O Ports Figure 5 1 Rear I O Ports Back Panel I O A IPMI LAN E LAN Port 1 1GbE B USB 3 0 Port 1 F LAN Port 4 10Gb Base T C USB 3 0 Port 0 G LAN Port 3 10 Gb Base T D LAN Port 2 1GbE...

Страница 46: ...which improves memory performance Check the Supermicro website for recommended memory modules CAUTION Exercise extreme care when installing or removing DIMM modules to prevent damage Memory Population...

Страница 47: ...r best memory performance install DIMM modules in pairs Installing DIMM Memory Modules 1 Align the key on the bottom of the DIMM module against the key on the memory slot Take note of the notches on t...

Страница 48: ...JBT1 IPMI_LAN JGPIO1 DESIGNED IN USA 1 X10SDV TLN4F REV 1 01 LED3 J6 BMC AST2400 i350 CPU JUIDB1 I SGPIO2 I SGPIO1 JF1 JL1 JOH1 JD1 PJ1 JSTBY1 JPW1 LED8 LED7 LEDM1 BT1 FAN3 FAN2 FAN1 COM1 VGA1 JTPM1 J...

Страница 49: ...7 Speaker JF1 Front Panel Control Header JIPMB1 4 pin External SMbus I2 C Header for an IPMI Card JL1 Chassis Intrusion Header JNVI2C1 NVMe I2C Header JOH1 Overheat LED Header JSD1 SATA DOM Device_On_...

Страница 50: ...Recovery Pins 1 2 Normal JPME2 Manufacturing Mode Pins 1 2 Normal JPTG1 10Gb Ethernet Enable Pins 1 2 Enabled JPUSB1 USB Wakeup Pins 1 2 Enabled For USB0 1 Only JWD1 Watch Dog Enable Pins 1 2 Reset L...

Страница 51: ...power is not in use The 4 pin power connector J6 provides power to onboard HDD devices ATX Power 24 pin Connector Pin Definitions JPW1 Pin Definition Pin Definition 13 3 3V 1 3 3V 14 NC 2 3 3V 15 COM...

Страница 52: ...g both pins will power on off the system This button can also be configured to function as a suspend button with a setting in the BIOS see Chapter 7 To turn off the power in the suspend mode press the...

Страница 53: ...description in Section 5 10 Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table on the right for pin definitions Power LED Pin Definitions JF1 Pin Definition 15...

Страница 54: ...entifier Switch A Unit Identifier UID Switch and two LED indicators are located on the motherboard The UID Switch is located next to the VGA port on the rear I O panel The rear UID LED LED7 is located...

Страница 55: ...cated at JL1 on the motherboard Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened Chassis Intrusion Pin Definitions JL1 Pin Definition 1 Int...

Страница 56: ...ail LED JOH1 Pin Definitions Pin Definition 1 3 3V 2 OH Active OH Fan Fail LED JOH1 Pin Definitions State Message Off Normal Solid Overheat Trusted Platform Module Header JTPM1 Pin Definitions Pin Def...

Страница 57: ...on 1 P3V3 2 GND 3 GP0 4 GP1 5 GP2 6 GP3 7 GP5 8 GP5 9 GP6 10 GP7 GPIO Header JGPIO1 The JGPIO1 header is located near the SATA connectors on the moth erboard The JGPIO header is a general purpose I O...

Страница 58: ...pins and Open means the jumper is either on only one pin or completely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Inste...

Страница 59: ...m or enter NMI when the Timer expires Close pins 1 2 to reset the system if an application hangs Close pins 2 3 to generate a non maskable interrupt signal for the application that hangs Open all pins...

Страница 60: ...tion mode online upgrade will be available via Recovery mode See the table on the right for jumper settings ME Recovery Jumper Settings Pin Definition 1 2 Normal Default 2 3 ME Recovery Manufacturing...

Страница 61: ...the system by pressing a key on the USB keyboard or by click ing the USB mouse of your system The JPUSB1 jumper is used together with the USB Wake Up function in the BIOS Enable both the jumper and t...

Страница 62: ...k Speed LED Activity LED LAN1 LAN4 LAN5 BMC Heartbeat LED Status Color State Definition Green Blinking BMC Normal BMC Heartbeat LED LED2 A BMC Heartbeat LED is located at LEDM1 See the table on the ri...

Страница 63: ...take precedence over the blue UID by default Press the UID switch again to turn off both 5 10 SATA Ports SATA Ports I SATA0 I SATA5 There are six SATA 3 0 ports on the motherboard These ports provide...

Страница 64: ...bsite at http www supermicro com products Find the product page for your motherboard here where you may download individual drivers and utilities After creating a CD DVD with the ISO files insert the...

Страница 65: ...a email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 M...

Страница 66: ...down which will reverse its polarites This battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Dispose of used batteries according to the manufact...

Страница 67: ...orts PCI Slot Control Panel 6 1 Static Sensitive Devices Electrostatic Discharge ESD can damage electronic com ponents To prevent damage to any printed circuit boards PCBs it is important to handle th...

Страница 68: ...ocedure to ensure that power has been removed from the system 1 Use the operating system to power down the system following the on screen prompts 2 After the system has completely shut down carefully...

Страница 69: ...as described in Section 6 2 2 Remove the five screws that hold the chassis cover in place There are two screws on each side of the chassis and one screw on the back 3 Once the screws have been remove...

Страница 70: ...Figure 6 4 One 3 5 Hard Drive and One Low Profile Expansion Card Figure 6 5 Two 2 5 Hard Drives and One Full Height Half Length Expansion Card 6 4 Installing Hard Drives Hard drives and expansion card...

Страница 71: ...Section 6 2 and remove the cover 2 Place the hard drives into the chassis as illustrated in figure 6 4 and 6 6 Orient a single drive with the cable connections facing the rear of the chassis Orient t...

Страница 72: ...them to the bracket with the screws provided 3 Place the hard drives and brackets into the chassis as illustrated in Figure 6 3 or Figure 6 5 Orient two or more drives with the cable connections facin...

Страница 73: ...the server Riser Card Slot Expansion Card Clip PCI E Slot Cover 6 5 Installing an Expansion Card The SC505 chassis includes a PCI slot An expansion card may be installed with one 3 5 or up to two 2 5...

Страница 74: ...s in the floor of the chassis 3 Secure the dual fan housing to the chassis with the screws provided 4 Position the single system fan next to the dual system fans Align the mounting holes in the single...

Страница 75: ...cess cabling out of the airflow path or use shorter cables 4 The control panel LEDs inform you of system status See Chapter 3 System Interface for details 6 7 Power Supply The SC505 chassis includes a...

Страница 76: ...s and extend upwards through the mounting holes to hold the power supply in place Set the screws aside for later use 8 Remove the power supply from the chassis 9 Align the mounting thru holes on the n...

Страница 77: ...s all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area r...

Страница 78: ...Do not update the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect specia...

Страница 79: ...g the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format...

Страница 80: ...se this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the n...

Страница 81: ...its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch Dog Timer will allow the system to reset or generate NMI based on...

Страница 82: ...to reduce the interference whenever needed The options are Enabled and Disabled Hyper Threading ALL Select Enable to use Intel Hyper Threading Technology to enhance CPU performance The options are Ena...

Страница 83: ...refetches the cache line for 64 bytes if this feature is set to Disabled The CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enable DCU Streamer Prefetcher Availab...

Страница 84: ...frequency to reduce power consumption and heat dissipation The options are Disable and Enable If the above is set to Enable CPU P State will display CPU P State Control P State Domain This feature al...

Страница 85: ...h converts HALT instructions to Mwait The options are Disable and Enable CPU C State Control CPU C State Use this feature to enable the enahnced C State of the CPU The options are Disable and Enable P...

Страница 86: ...ng When enabled this item selects whether the BIOS or Operating System can turn on the energy performance bias tuning The options are Enable and Disable If the above is set to Disable Energy Performan...

Страница 87: ...de The options are Enable and Disable DRAM RAPL Configuration DRAM RAPL Extended Range Use this feature to set the DRAM Running Average Power Limit RAPL Extended Range The options are Disable and Enab...

Страница 88: ...resource for other tasks The options are Enable and Disable No Snoop Select Enable to support no snoop mode for each CB device The options are Disable and Enable Intel VT for Directed I O VT d Intel...

Страница 89: ...nd data integrity The options are Auto Disabled and Enabled DRAM RAPL Baseline Use this feature to set the run time power limit baseline for DRAM modules The options are Disable DRAM RAPL Mode 0 and D...

Страница 90: ...performed Use the keyboard to enter a value from 0 24 The Default setting is 24 Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory m...

Страница 91: ...bled EHCI2 Select Enabled to enable EHCI Enhanced Host Controller Interface support on USB 2 0 connector 2 at least one USB 2 0 connector should be enabled for EHCI support The options are Disabled an...

Страница 92: ...ve Support Port 0 Port 5 Hot Plug This feature designates this port for hot plugging Set this item to Enabled for hot plugging support which will allow the user to replace a SATA drive without shuttin...

Страница 93: ...ERR SERR number for a PCI Bus Signal Error Event The options are Enabled and Disabled SR IOV Available if the system supports Single Root Virtualization Select Enabled for Single Root IO Virtualizatio...

Страница 94: ...Enabled to enable Option ROM support to boot the computer using a network device specified by the user The options are Disabled Legacy and EFI Onboard LAN1 Option ROM Use this option to select the ty...

Страница 95: ...2 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port Console Redirection COM1 Console Redirection Console Redirection Select Enabled to...

Страница 96: ...to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a...

Страница 97: ...o Enabled the following items will become available for user s configuration SOL Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client compu...

Страница 98: ...r Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiv...

Страница 99: ...feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Management Port The feature selects a ser...

Страница 100: ...elect Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data packet Select 1 Stop Bit...

Страница 101: ...port Select Enabled to support Runtime Error Logging The options are Enable and Disable If this item is set to Enable the following item will be available for configuration Memory Corrected Error Enab...

Страница 102: ...log memory is full The options are Do Nothing and Erase Immediately SMBIOS Event Long Standard Settings Log System Boot Event This option toggles the System Boot Event logging to enabled or disabled...

Страница 103: ...agement Controller This item indicates the status of the IPMI firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging a...

Страница 104: ...s Shared LAN Update IPMI LAN Configuration Select Yes for the BIOS to implement all IP MAC address changes at the next system boot The options are No and Yes Configuration Address Source This feature...

Страница 105: ...igit number separated by dots should not exceed 255 Station MAC Address This item displays the Station MAC address for this computer Mac addresses are 6 two digit hexadecimal numbers Gateway IP Addres...

Страница 106: ...BIOS Setup utility The options are Setup and Always Administrator Password Press Enter to create a new or change an existing Administrator password CSM Support Select Enabled to support the EFI Compa...

Страница 107: ...the manufacturer The options are Yes and No Save All Secure Boot Variables This feature allows the user to decide if all secure boot variables should be saved Platform Key PK This feature allows the u...

Страница 108: ...ct Yes to load the DBX from the manufacturer s defaults Select No to load the DBX from a file The options are Yes and No Append New Key Select Yes to add the DBX from the manufacturer s defaults to th...

Страница 109: ...etting is 1 Boot Mode Select Use this item to select the type of device that the system is going to boot from The options are Legacy UEFI and Dual The default setting is Dual Fixed Boot Order Prioriti...

Страница 110: ...se this feature to remove a pre defined boot device from which the system will boot during startup The settings are any pre defined boot device Network Drive BBS Priorities This feature allows the use...

Страница 111: ...BIOS setup utility and reboot the computer so the new system configuration parameters can take effect Select Save Changes and Exit from the Exit menu and press Enter Save Options Save Changes After co...

Страница 112: ...as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults f...

Страница 113: ...ors will not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs BIOS POST Error Codes Beep Code Error Mess...

Страница 114: ...A 2 SUPERSERVER 5018D FN4T User s Manual Notes...

Страница 115: ...8GB 16GB and 32GB 32GB for RDIMM only Dual Rank Data width x4 SATA Controller Six SATA3 6Gbps connectors Drives Supports one or two 3 5 hard drives or up to four 2 5 hard drives optional mounting bra...

Страница 116: ...g Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 8 to 90 non condensing Non Operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class...

Страница 117: ...orm be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pro...

Страница 118: ...B 4 SUPERSERVER 5018D FN4T User s Manual Notes...

Отзывы: