Supermicro 1029U-TRTP Скачать руководство пользователя страница 65

65

Chapter 4: Motherboard Connections

4.4 Jumpers

Explanation of Jumpers

To modify the operation of the motherboard, jumpers are used to choose between optional 
settings. Jumpers create shorts between two pins to change the function associated with it. 

Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard 

layout page for jumper locations.

Note:

 On a two-pin jumper, "Closed" means the jumper is on both pins and "Open" indicates 

the jumper is either on only one pin or has been completely removed.

Connector

Pins

Jumper

Setting

3      2      1

3      2      1

CMOS Clear

JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper 
consists of contact pads to prevent accidentally clearing the contents of CMOS. 

To Clear CMOS

1. First power down the system and unplug the power cord(s).

2. Remove the cover of the chassis to access the motherboard.

3. Remove the onboard battery from the motherboard.

4. Short the CMOS pads with a metal object such as a small screwdriver for at least four 

seconds.

5. Remove the screwdriver (or shorting device).

6. Replace the cover, reconnect the power cord(s) and power on the system.

Notes:

 Clearing CMOS will also clear all passwords.

Do not use the PW_ON connector to clear CMOS.

JBT1 contact pads

Содержание 1029U-TRTP

Страница 1: ...USER S MANUAL Revision 1 0j SuperServer SYS 1029U T Series...

Страница 2: ...n industrial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful i...

Страница 3: ...rivers and utilities https www supermicro com wdl Product safety info https www supermicro com about policies safety_information cfm If you have any questions please contact our support team at suppor...

Страница 4: ...rning Merchandise for Service 17 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considera...

Страница 5: ...nk Module 33 Memory 34 Memory Support 34 Memory Population Guidelines 35 Memory Population Sequence 35 DCPMM Population Table 24 Slots based on the 82xx 62xx 52xx 42xx 38 Installing Memory 40 Motherbo...

Страница 6: ...ft Windows OS Installation 70 5 2 Driver Installation 72 5 3 SuperDoctor 5 73 5 4 BMC 74 Chapter 6 UEFI BIOS 6 1 Introduction 75 Starting BIOS Setup Utility 75 6 2 Main Setup 75 6 3 Advanced Setup Con...

Страница 7: ...ddress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl...

Страница 8: ...below Main Parts List Description Part Number Quantity Power supply modules PWS 751P 1R 2 Backplane BPN SAS3 116A N2 1 Fans FAN 0101L4 8 Air Shrouds MCP 310 81910 0N MCP 310 81911 0N 1 each Heatsinks...

Страница 9: ...r Non Volatile DIMM NVDIMM and Intel Optane DC Persistent Memory DCPMM Chipset Intel C621 Expansion Slots Two full height full width PCI E slots one low profile PCI E slot one internal low profile PCI...

Страница 10: ...being supplied to the system power supply units This LED is illuminated when the system is operating normally 4 HDD Indicates activity on the hard drive when flashing 5 NIC LED Indicates network acti...

Страница 11: ...rage Drives Ten 2 5 drive bays see the Storage Drive section in Chapter 3 4 for details 4 Service Asset Tag Pull out identifier with BMC ADMIN default password underneath see figure below Chassis Fron...

Страница 12: ...nding on your Ultra riser card see Section 1 1 Overview for details also see LAN numbering description below 3 USB Two USB 3 0 ports 4 BMC LAN Dedicated LAN port for BMC 5 COM Serial port 6 UID UID in...

Страница 13: ...I2C2 T SGPIO3 BP PWR2 BP PWR4 BP PWR3 BP PWR1 PSU1 PSU2 P1_NVMe1 P1_NVMe0 JNVI2C1 GPU PWR1 SXB3A SXB3B SXB3C SP1 BT1 JBT1 JRK1 JWD1 JVRM1 SXB1C SXB1B SXB1A SXB2 GPU PWR2 GPU PWR4 GPU PWR3 JSD1 JSD2 US...

Страница 14: ...vices JSD1 JSD2 SATA DOM power connectors 1 2 JSDCARD1 Micro SD card slot reserved for manufacture use JTPM1 Trusted Platform Module Port 80 connector JUIDB2 UID Unit Identifier switch JVGA2 Front VGA...

Страница 15: ...E1 LED_P1_E2 Memory Fault LEDs for Memory Module P1_ E1 Memory Module P1_E2 Solid Red Memory Error Occurs LED_P1_F1 LED_P1_F2 Memory Fault LEDs for Memory Module P1_ F1 Memory Module P1_F2 Solid Red M...

Страница 16: ...16 SuperServer SYS 1029U T Series User s Manual Figure 1 7 System Block Diagram SYS 1029U TR4 TRT TRTP TRTP2 TR25M System Block Diagram System Block Diagram CPU2 Socket 01 CPU1 Socket 00...

Страница 17: ...be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is compl...

Страница 18: ...ck Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas wher...

Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 20: ...ply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special pr...

Страница 21: ...specific rack you are using If you are installing into a two post telco rack skip to that section later in this chapter Identifying the Rails The chassis comes with two sets of rack rails one set for...

Страница 22: ...Push the rail into the rack until the quick release bracket snaps into place securing the rail to the rack Keep the rail horizontal 2 Adjust the rail to reach just past the full depth of your rack 3 A...

Страница 23: ...dle rails and then push evenly on both sides of the chassis until it clicks into the fully extended position 3 Depress the locking tabs on both sides of the chassis and push the it fully into the rack...

Страница 24: ...tance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack...

Страница 25: ...chassis should be positioned so that the weight is balanced between front and back 2 Attach the two front brackets to each side of the chassis then the two rear brackets positioned with just enough sp...

Страница 26: ...se follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing n...

Страница 27: ...of the chassis Removing the Top Cover 1 Press the two release buttons and slide the cover toward the rear 2 Lift the top cover up Check that all ventilation openings on the top cover and the top of th...

Страница 28: ...socket and none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation...

Страница 29: ...nt Installation Overview of the Processor Heatsink Module The Processor Heatsink Module PHM contains a heatsink a processor carrier assembly Heatsink with Thermal Grease Processor Carrier Processor Pr...

Страница 30: ...Using the triangles as a guide carefully align and place Point A of the processor into Point A of the carrier Then gently flex the other side of the carrier for the processor to fit into Point B 3 Exa...

Страница 31: ...sor carrier assembly so the processor s gold contacts are facing up then align the triangle on the assembly with hole 1 of the heatsink Press the processor carrier assembly down The plastic clips of t...

Страница 32: ...This motherboard comes with a plastic protective cover on the CPU socket Remove it carefully to install the Processor Heatsink Module PHM CPU Socket with Plastic Protective Cover Socket Pins Remove t...

Страница 33: ...screws 1 4 to assure even pressure The order of the screws is shown on the label on top of the heatsink To avoid damaging the processor or socket do not use a force greater than 12 lbf in when tighten...

Страница 34: ...B RDIMM 3Ds QRX4 N A 2H 64GB 8RX4 N A 4H 128GB LRDIMM QRx4 32 GB 64 GB LRDIMM 3Ds QRx4 N A 2H 64GB 8Rx4 N A 4H 128 GB DDR4 Memory Support for 82xx 62xx 52xx 42xx 32xx Processors Type Ranks Per DIMM an...

Страница 35: ...be mixed in the same channel Mixing of LRDIMMs and RDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of non 3DS and 3DS LRDIMM is not allowed in...

Страница 36: ...U2 P2 DIMMC1 P2 DIMMB1 P2 DIMMA1 2 CPUs 8 DIMMs CPU1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P1 DIMME1 CPU2 P2 DIMMB1 P2 DIMMA1 P2 DIMMD1 P2 DIMME1 2 CPUs 10 DIMMs CPU1 P1 DIMMC1 P1 DIMMB1 P1 DIMMA1 P1 DIMMD1 P...

Страница 37: ...P1 DIMMA2 P1 DIMMD2 P1 DIMME2 P1 DIMMD1 P1 DIMME1 P1 DIMMF2 P1 DIMMF1 P1 DIMMB1 P1 DIMMC1 P1 DIMMB2 P1 DIMMC2 CPU2 P2 DIMMA1 P2 DIMMA2 P2 DIMMD2 P2 DIMME2 P2 DIMMD1 P2 DIMME1 P2 DIMMF2 P2 DIMMF1 P2 D...

Страница 38: ...DCP 1 1 1 MM DCP M1 M1 M1 M1 DCP 1 1 1 AD MM DCP M3 M3 M3 M3 DCP 1 1 1 4 DCP 16 DIMM AD DCP M1 M1 M1 M1 M1 M1 M1 M1 DCP 2 2 1 AD App Direct MM Memory Mode M1 M2 M3 DRAM see Legend below Asymmetric Po...

Страница 39: ...ulting population is compliant with the PDG rules for the 82xx 62xx 52xx 42xx platform For each individual population use the same DDR4 DIMM in all slots For each individual population sockets are nor...

Страница 40: ...as described in Section 3 1 and remove the node from the chassis Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it No...

Страница 41: ...Replacing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of...

Страница 42: ...ssis These carriers also help promote proper airflow Drive Carrier Indicators Each drive carrier has two LED indicators an activity indicator and a status indicator For RAID configurations using a con...

Страница 43: ...button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the chassis Figure 3 6 Removing a Drive Carrier 1 2 Installing Drives The...

Страница 44: ...oward the rear of the carrier Align the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure the drive to t...

Страница 45: ...and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture The 1029U T Series ser...

Страница 46: ...of an NVMe Drive There are two ways to check using IPMI Checking a Drive IPMI Server Health NVMe SSD Shows the temperatures of all NVMe drives as in Figure 3 4 IPMI Server Health Sensor Reading NVME_...

Страница 47: ...an unit is actually made up of two fans joined back to back which rotate in opposite directions This counter rotating action generates exceptional airflow and works to dampen vibration levels Make sur...

Страница 48: ...eriod of time with the chassis cover open 2 Power down the system as described in section 3 1 3 Unplug the fan cable from the serverboard and remove the failed fan from the chassis 4 Replace the faile...

Страница 49: ...serverboard air shroud does not require screws to install Installing the Air Shroud 1 Position the air shroud in the chassis as illustrated below 2 Align the notch on the air shroud with the pin on t...

Страница 50: ...ee Control Panel in Chapter 1 for details Overheating There are several possible responses if the system overheats Overheat Temperature Setting Some backplanes allow the overheat temperature to be set...

Страница 51: ...n illuminated indicates that the power supply is on Blinking Green When blinking indicates that the power supply is plugged in and turned off by the system Blinking Amber When blinking indicates that...

Страница 52: ...length x8 CPU2 3 Full Height full length x16 CPU2 4 Full Height full length x16 CPU2 Full height 4 2 Low profile 2 5 Full length 10 5 Half length 6 6 This slot supports only Supermicro SAS Cards list...

Страница 53: ...Expansion Slots 3 If necessary attach the riser card to the riser card bracket using screws 4 Insert the expansion card into a slot on the riser card while aligning the expansion card backplate with...

Страница 54: ...SuperServer 1029U T Series User s Manual 54 Figure 3 15 Expansion cards Installed Expansion Cards Internal Expansion Card...

Страница 55: ...Installing the Internal Expansion Card 1 Remove the cover 2 Locate the mounting bracket in the accessories box Mount the bracket to hold the SAS expansion card onto the Ultra riser card Figure 3 16 Br...

Страница 56: ...remove the Ultra riser card use two hands One hand lifts the mylar release tab and the other hand lifts at the PCI E x8 slot at the same time Caution Lifting at only one of these points may cause dama...

Страница 57: ...t PSU1 and PSU2 Connect appropriate power supply units to these two headers to provide adequate power to your system Important To provide adequate power to the motherboard connect the both main power...

Страница 58: ...Black 2 12V Red 3 Tachometer 4 PWM Control T SGPIO3 Header A Serial General Purpose Input Output header T SGPIO3 is located next to the TPM Port 80 on the motherboard This header is used to communicat...

Страница 59: ...ve is not installed in the system Internal Speaker Buzzer The Internal Speaker Buzzer SP1 is used to provide audible indications for various beep codes Internal Buzzer Pin Definitions Pin Definition 1...

Страница 60: ...t JSDCARD1 Micro SSD card slot reserved for manufacture use only RAID Key Header Pin Definitions Pin Definition 1 Ground 2 RAID_KEY_PU 3 Ground 4 PCH_RAID_KEY NVMe SMBus Headers NVMe SMBus I2 C header...

Страница 61: ...nd Key Power On LED Control signal HDD LED Activity signal NIC1 LED Ground NIC2 LED Ground OH Fan Fail LED Ground Power Fail LED Ground Ground Ground 2 1 20 19 Power Button Pin Definitions JF1 Pin Def...

Страница 62: ...LED 8 OH Fan Fail LED LAN1 LAN2 LED Pin Definitions JF1 Pin Definition 9 NIC2 Activity LED 10 NIC2 Link LED 11 NIC1 Activity LED 12 NIC1 Link LED NIC1 NIC2 LAN1 LAN2 The NIC Network Interface Control...

Страница 63: ...nection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Power LED NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 NM...

Страница 64: ...the chassis rear provided by the Ultra add on card depending on the model There is also a dedicated IPMI LAN port on the I O back panel For more information on IPMI refer to the IPMI User s Guide post...

Страница 65: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearin...

Страница 66: ...the application that hangs Watch Dog must also be enabled in BIOS The default setting is Reset Note When Watch Dog is enabled the user needs to write their own application software to disable it Watc...

Страница 67: ...on and off Be sure to turn off the system and unplug the power cord s before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Off power cable not connected...

Страница 68: ...n Status LED_P1_A1 A2 Memory Fault LEDs for Memory Module P1_A1 A2 Red on memory errors LED_P1_B1 B2 Memory Fault LEDs for Memory Module P1_B1 B2 Red on memory errors LED_P1_C1 C2 Memory Fault LEDs fo...

Страница 69: ...r cables Supermicro SuperDOMs are backward compatible with regular SATA HDDs or SATA DOMs that need external power cables NVM Express Connections Four NVM Express ports are located on the motherboard...

Страница 70: ...tion User Guides posted on our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That can be a USB flash or media drive 2...

Страница 71: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...

Страница 72: ...preferred Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the fla...

Страница 73: ...email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Ma...

Страница 74: ...documentation and information on BMC visit our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each system is assigned a unique defau...

Страница 75: ...selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the Enter key opens the list of sett...

Страница 76: ...Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30...

Страница 77: ...re to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST me...

Страница 78: ...m a Legacy boot device after an initial boot failure The options are Disabled Legacy Boot and EFI Boot Install Windows 7 USB support Enable this feature to use the USB keyboard and mouse during the Wi...

Страница 79: ...voltage control during processor idle states Select Enabled to decrease the system power by throttling CPU frequency when one power supply is failed The options are Disabled and Enabled CPU Configura...

Страница 80: ...website for detailed information PPIN Control Select Unlock Enable to use the Protected Processor Inventory Number PPIN in the system The options are Unlock Disable and Unlock Enable Hardware Prefetc...

Страница 81: ...is set to Enable Select Enable to allow the BIOS to configure high priority CPU cores as Prioritized Base Frequency PBF so that software programs do not have to configure the PBF Prioritized Base Freq...

Страница 82: ...the CPU s clock cycle and voltage during a Halt state The options are Disable and Enable Package C State Control Package C State This feature allows the user to set the limit on the C State package r...

Страница 83: ...Dis able Enable and Auto IO Directory Cache IODC Use this feature to enable the IO Directory Cache IODC support The options are Dis able Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow E...

Страница 84: ...ble to enable data scrambling to enhance system performance and data in tegrity The options are Auto Disable and Enable Data Scrambling for DDR4 Use this feature to enable data scrambling for DDR4 The...

Страница 85: ...are One Rank and Two Rank Correctable Error Threshold Use this feature to enter the threshold value for correctable memory errors The default setting is 10 SDDC Plus One Single Device Data Correction...

Страница 86: ...e user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU1 IIO PCIe Br2 This feature configures the PCI E port Bifurcation setting for a PCI E port specified by the user The options are x4x4...

Страница 87: ...del Link Speed This feature allows the user to select PCI E support for the device installed in the system The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s PCI E Port Link Status PCI...

Страница 88: ...I E Port Link Status PCI E Port Link Max PCI E Port Link Speed PCI E Port Max Payload Size Select Auto for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance...

Страница 89: ...Me0 Link Speed This feature allows the user to select PCI E support for the device installed in the system The options are Auto Gen 1 2 5 GT s Gen 2 5 GT s and Gen 3 8 GT s PCI E Port Link Status PCI...

Страница 90: ...for the system BIOS to automatically set the maximum payload value for a PCI E device to enhance system performance The options are 128B 256B and Auto RSC R1UW 2E16 SLOT2 Link Speed This feature allow...

Страница 91: ...haring across Intel platforms providing greater reliability security and availability in networking and data sharing The options are Enable and Disable ACS Control The options Enable programs the ACS...

Страница 92: ...ns are Disable and Enable P1_NVMe1 VMD Select Enable to use the Intel Volume Management Device Technology for this device The options are Disable and Enable Hot Plug Capable Use this feature to enable...

Страница 93: ...ntel VMD for Volume Management Device on CPU2 Intel VMD for Volume Management Device for PStack1 Select Enable to use the Intel Volume Management Device Technology for this stack The options are Disab...

Страница 94: ...tions are Disable and Enable Hot Plug Capable Use this feature to enable the hot plug support for PCIe root ports 3A 3D The options are Disable and Enable IIO PCIE Express Global Options PCI E Complet...

Страница 95: ...supported by the Intel PCH chip The options are Disable and Enable Configure SATA as Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive...

Страница 96: ...the feature Configure SATA as is set to RAID the following features are available SATA RSTe Boot Info Select Enable to provide the full int13h support for SATA controller attached devices The options...

Страница 97: ...sSATA as Select AHCI to configure a SATA drive specified by the user as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID SATA HDD...

Страница 98: ...er attached devices The options are Disable and Enable sSATA RAID Option ROM UEFI Driver Select EFI to load the EFI driver for system boot Select Legacy to load a legacy driver for system boot The opt...

Страница 99: ...ect Enabled to activate PCI Error and System Error report handling The options are Disabled and Enabled Maximum Read Request Select Auto to allow the system BIOS to automatically set the maximum read...

Страница 100: ...elect the type of device installed in a LAN port specified by the user for system boot The default setting for Onboard LAN1 Option ROM is PXE and the default setting for Onboard LAN2 Option ROM is Dis...

Страница 101: ...t setting is 1 Super IO Configuration Super IO Configuration The following Super IO information will be displayed Super IO Chip AST2500 Serial Port 1 Configuration Serial Port 1 Configuration This sub...

Страница 102: ...9 10 11 12 and IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Attribute Available for Serial Port 2 only Select SOL to use COM Port 2 as a Serial Over LAN SOL port for console redirection The options...

Страница 103: ...a parity bit with your data bits in transmission Select Mark to add a mark as a parity bit to be sent along with the data bits Select Space to add a Space as a parity bit to be sent with your data bit...

Страница 104: ...ied by the user The options are Disabled and Enabled If the feature above is set to Enabled the following features will become available for user s configuration Console Redirection Settings This feat...

Страница 105: ...feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to...

Страница 106: ...tions are Disabled and Enabled If the feature above is set to Enabled the following features will become available for user s configuration Console Redirection Settings This feature allows the user to...

Страница 107: ...ery and health monitoring The options are Disabled and Enabled High Precision Event Timer Select Enabled to activate the High Precision Event Timer HPET that produces periodic interrupts at a much hig...

Страница 108: ...None and TPM Clear Platform Hierarchy Use this feature to disable or enable platform hierarchy for platform protection The options are Disabled and Enabled Storage Hierarchy Use this feature to disabl...

Страница 109: ...iguration When this submenu is selected the following features will be displayed Server CA Configuration This feature allows the user to configure the client certificate that is to be used by the serv...

Страница 110: ...llowing features Add an Attempt Delete Attempts Change Attempt order Intel Virtual RAID on CPU This submenu displays the information of the Intel VMD controllers as detected by the BIOS Intel Optane T...

Страница 111: ...DIMM UID 8089 A2 1837 0000115D DIMM handle 0x0001 DIMM physical ID 0x0019 Manageability state Manageable Health state Healthy Health state reason None Capacity 252 4 GiB Firmware version 01 00 00 5127...

Страница 112: ...uring location 0xA2 Memory type Logical Non Volatile Device Memory bank label P0_Node0_Channel0_Dimm1 Data width label b 64 Total width b 72 Speed MHz 2666 Channel ID 0x0000 Channel position 1 Revisio...

Страница 113: ...Command Received PMIC 12V DDRT 1 2V Power Loss PLI Controller s FW State Flush Complete Write Data Flush Complete PM Idle Received Unlatched last shutdown status Unknown Security capabilities Encrypt...

Страница 114: ...Choices are 1 and 0 Sensor Type Media temperature Value 39 C Non critical threshold 82 Critical lower threshold 83 Critical upper threshold 83 Fatal threshold 85 State Normal Alarm enabled state Use t...

Страница 115: ...changes Press Enter to apply changes Update firmware Specify the firmware image to load on the DIMMs on the next system restart and select Update Current firmware version 01 00 00 5127 Selected firmw...

Страница 116: ...reboot Configure data policy Specify the data policy settings on ALL the DIMMs First fast refresh state Disabled or Enabled Depending on the settings of the following feature Enable Disable first fas...

Страница 117: ...pe of the new region then set the desired sizes Create goal config for Use this feature to select target to create goal configuration The options are Platform and Socket Reserved Enter a value 0 100 t...

Страница 118: ...pace has been created it is displayed here NamespaceID Name Health Status 0x00000101 Healthy Use this feature to display details for or modify selected namespace View details for or modify selected na...

Страница 119: ...a block translation table BTT Capacity input The options are Remaining and Manual Set this feature to Remaining to use the maxi mum available capacity Set this feature to Manual to enter the capacity...

Страница 120: ...led to enable the diagnostics procedure for this DIMM The options are Dis abled and Enabled Additional DIMMs are listed if detected Config diagnostics Select Enabled to enable the platform configurati...

Страница 121: ...and UID Capacity units This feature is to modify the default units for displaying capacities Use auto x1024 or Auto_10 x1000 to automatically select the best format The options are Auto Auto_10 B MB M...

Страница 122: ...sistent Memory DIMM 41 Controller Healthy Additional controllers are listed if detected Intel R DCPMM 1 0 0 3380 HII Driver Healthy Controller 665c5c98 Child 0 Healthy Intel R 10GbE Driver 7 0 19 x64...

Страница 123: ...e SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing Settings Erase Event Log If No is selected data stored in the event log will not be erased...

Страница 124: ...nd Disabled MECI The Multiple Event Count Increment MECI counter counts the number of occurrences that a duplicate event must happen before the MECI counter is incremented This is a numeric value The...

Страница 125: ...firmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Disabled and Enabled Erasing Settings...

Страница 126: ...to Yes the following items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static i...

Страница 127: ...led If the item above is set to Enabled the following items will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP addr...

Страница 128: ...sword Press Enter to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup fo...

Страница 129: ...Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Enroll all Factory Default Keys Select Yes to install all default secure keys set by the m...

Страница 130: ...idden Signatures Forbidden Signature Database DBX contains forbidden certificates and digital signa tures Select Set New to load the DBX from the manufacturer s defaults Select Append to add the DBX f...

Страница 131: ...e EFI boot support The options are Disabled and Enabled FIXED BOOT ORDER Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from to...

Страница 132: ...ture to remove a pre defined boot device from which the system will boot during startup The options are Select one to Delete and UEFI Built in EFI Shell UEFI Application Boot Priorities This feature a...

Страница 133: ...s and Exit from the Exit menu and press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will reset reboot the s...

Страница 134: ...em stability but not for maximum performance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the...

Страница 135: ...corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No m...

Страница 136: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 137: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 138: ...rken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan...

Страница 139: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 140: ...ntes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l ins...

Страница 141: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 142: ...kabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment W...

Страница 143: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 144: ...o a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 145: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 146: ...t aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...

Страница 147: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 148: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...

Страница 149: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 150: ...nale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accor...

Страница 151: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 152: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...

Страница 153: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 154: ...ur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...

Страница 155: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 156: ...support SAS with an optional add on card two are hybrid ports that can support NVMe additional cables required Two SuperDOM Disk on Module headers PCI Expansion Slots Two PCIe x16 full height full le...

Страница 157: ...4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU and Delegated Directive EU 2015...

Страница 158: ...age The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the syste...

Страница 159: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...

Страница 160: ...e if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed...

Страница 161: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 162: ...interrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power...

Страница 163: ...urpose you can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2...

Страница 164: ...ystem remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellanous tab then the Tro...

Страница 165: ...pid Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise I...

Страница 166: ...r JRK1 The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd pa...

Страница 167: ...2 1029U T VMD Config for PStack0 not needed 6019U TN4 2029U T 2029U E1C 2029UZ T 6029U T 6029U E1C 6029UZ T VMD Config for PStack0 VMD Config for PStack0 1029U TN10 VMD Config for PStack1 VMD Config f...

Страница 168: ...F 2 BIOS VMD Setting Examples for Ultra Servers For 2029U TN24R4T populated with 24 U 2 NVMe drives CPU1 Configuration CPU2 Configuration CPU2 Configuration CPU1 Configuration For 2029U TR or 2029U E1...

Страница 169: ...ID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAID is required select Enable RAID spanned over VMD Controller as shown in Figure F 4 12 Sel...

Страница 170: ...the device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article...

Отзывы: