background image

4 | 

  

• Before beginning, please read these instructions completely and
  carefully.
• DO NOT remove  permanently  affixed  labels,  warnings,  or 

plates from product.This may void the warranty. 

•  All local and national codes and ordinances must be observed. 
  Installation must conform with local codes or in the absence of 

codes, the National Fuel Gas Code ANSIZ223.1 INFPA54.

• The installer must leave these instructions with the consumer 

who  should  retain  for  local  inspector’s  use  and  for  future 
reference.

In Canada: Installation must be in accordance with the current 
CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. 
Electrical  installation  must  be  in  accordance  with  the  current 
CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.

In Massachusetts:  All  gas  products  must  be  installed  by  a 
“Massachusetts” licensed plumber or gasfitter. A “T” type handle 
manual  valve  must  be  installed  in  the  gas  supply  line  to  the 
appliance.

An air curtain or other overhead range hood which operates by 
blowing a downward airflow onto the range, shall not be used 
with a gas range.

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual 
and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. 
This symbol alerts you to hazards that can kill or hurt 
you and others.

All safety messages will be preceded by the safety alert symbol 
and the word“DANGER,” “WARNING” or “CAUTION.”
These words mean:

 

 

DANGER

 

Hazards or unsafe practices which WILL result in severe 
personal injury or death.
 

 

 

WARNING

 

Hazards or unsafe practices which COULD result in 
severe personal injury or death.

 

 

CAUTION

 

Hazards or unsafe practices which COULD result in 
minor personal injury or property damage. 

All  safety  messages  will  identify  the  hazard,  tell  you  how  to 

reduce the chance of injury, and tell you what can happen if the 
instructions are not followed.

A GFI shall be used if required by NFPA-70 (National 
Electric Code), federal/state/local laws, or local 
ordinances.
•  The required use of a GFI is normally related to the location 

of a receptacle with respect to any significant sources of water 
or moisture.

•  SUPERIORE  will NOT warranty any problems resulting from 

GFI outlets which are not installed properly or do not meet 
the requirements below.

If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT 

recommended)

•  Used  with  permanent  wiring  only  (temporary  or  portable 

wiring NOT recommended)

• On a dedicated circuit (no other receptacles, switches or loads 

in the circuit)

•  Connected  to  a  standard  breaker  of  appropriate  size  (GFI 

breaker of the same size NOT recommended)

• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 

standard

•  In  good  condition  and  free  from  any  loose-fitting  gaskets  (if 

applicable in outdoor situations)

•  Protected from moisture (water, steam, high humidity) as much 

as reasonably possible.

 

 

WARNING

 

To prevent possible damage to cabinets and cabinet finishes, use 
only materials and finishes that will not discolor or delaminate 
and  will  withstand  temperatures  up  to  194°F  (90°C).  Heat 
resistant adhesive must be used if the product is to be installed in 
laminated cabinetry.  Check with your builder or cabinet supplier 
to make sure that the materials meet these requirements.

Warnings & Important Safety Instructions  

Содержание R***241 Series

Страница 1: ...Installation manual for all 24 30 36 and 48 ranges...

Страница 2: ...of this or any other appliance WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier...

Страница 3: ...Electrical Gas Requirements Gas Requirements General Information Installation Door Removal Leg Installation Adjustments Alignments Anit tip Device Installation Connecting Gas Electrical Final Preparat...

Страница 4: ...ING Hazards or unsafe practices which COULD result in severe personal injury or death CAUTION Hazards or unsafe practices which COULD result in minor personal injury or property damage All safety mess...

Страница 5: ...PA 70 latest edition WARNING MOVING HAZARD To avoid risk of severe personal injury this appliance requires two or more personnel while handling and moving Possible use of appliance moving devices is r...

Страница 6: ...ERIORE Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 23 7 8 23 2 2 3 16 35 7 8 min 37 5 16 max 1 3 8 Di...

Страница 7: ...2 25 2 2 1 1 2 5 Gas 33 1 11 32 2 6 8 1 3 8 23 7 8 29 7 8 3 8 Electricity 2 1 8 5 5 9 16 35 7 8 min 37 5 16 max 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min 4 1 4 max 2 2...

Страница 8: ...UPERIORE Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 29 7 8 23 2 2 3 16 35 7 8 min 37 5 16 max 1 3 8 Dime...

Страница 9: ...25 2 2 1 1 2 5 Gas 33 1 11 32 2 6 8 1 3 8 29 7 8 29 7 8 3 8 Electricity 2 1 8 5 5 9 16 35 7 8 min 37 5 16 max 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min 4 1 4 max 2 27...

Страница 10: ...Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 35 7 8 min 37 5 16 max 35 7 8 23 2 33 2 3 16 1 3 8 36 SUPERIORE Ranges Di...

Страница 11: ...2 2 33 35 7 8 2 1 8 25 2 2 Gas 1 3 8 35 7 8 Electricity 5 5 9 16 1 1 2 5 1 11 32 2 6 8 3 8 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min 4 1 4 max 2 27 64 1 3 8 1 3 8 36 S...

Страница 12: ...es are equipped with spacer on the back 25 64 to prevent over heating of the wall Dimensions Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent...

Страница 13: ...PERIORE Ranges Dimensions 2 4 33 47 7 8 2 1 8 25 2 2 Gas 1 3 8 47 7 8 Electricity 5 5 9 16 1 1 2 5 1 11 32 2 6 8 3 8 2 3 8 4 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min...

Страница 14: ...es 135 8000 82 8000 Feeding 120 V 60 Hz 130 W Feeding dual fuel s c ranges 120 V 240 60 Hz Interior dimensions 2413 64 x 1957 64 x 2031 64 Only on mod 361 2 burners on mod 361 1 burner on mod 362 Spec...

Страница 15: ...rior dimensions 283 4 x 1957 64 x 2031 64 Specifications Technical data Burners injectors and volume Range Mod R 482 Methane 4 LPG 10 By pass Burners Inj W BTU h Inj W BTU h W BTU h Small burner 92 36...

Страница 16: ...cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above the range must be a minimum of 42 106 7 cm above the range cooking...

Страница 17: ...information These dimensions provide for safe and efficient operation of the hood Important There must be a minimum of 6 15 2 cm clearance from rear of range to a combustible wall Clearances from non...

Страница 18: ...y Manual shut off valve This installer supplied valve must be installed in the gas service line before the appliance in the gas stream and in a location where it can be reached quickly in the event of...

Страница 19: ...below to assemble the pressure regulator 3 Screw the assembled pressure regulator on the range like shown on picture below Pay attention to the vertical alignement of the same pressure regulator 4 Sc...

Страница 20: ...st not be connected to the power and or gas lines 1 Remove the main back cover unscrewing the two screws 2 Remove the gas regulator back cover unscrewing the single screw 3 Fit the elbow on the regula...

Страница 21: ...setting The conversion is not completed if all 6 steps have not been concluded properly Before performing the gas conversion locate the package containing the replacement nozzle shipped with every ra...

Страница 22: ...rinted on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners STEP3 FORALL GASRANGESONL Y MAINOVENBURNER To replace the nozzles of the main oven burne...

Страница 23: ...or 10 mm sochet wrench to unscrew the nozzle Replace the nozzle using the conversion set supplied with the range or by a Tecno authorized parts warehouse Each nozzle has a number indicating its flow d...

Страница 24: ...alve Using a small size slotted screwdriver locate the By pass screw valve on the valve body and turn it to the right or left until the burner flame is adjusted to desired minimum 4 Make sure that the...

Страница 25: ...rvice Center before continuing operation Failure to do so can result in damage to the oven or surrounding cabinets Moving Handling and Unpacking Remove and discard all packing materials including card...

Страница 26: ...st be done by your dealer a qualified licensed plumber or certified gas installer 1 2 3 Door Removal 1 Open the door completely Place the pins supplied with unit in pin hole For personal safety ONLY u...

Страница 27: ...d on the lower part of the appliance Lower the range gently to keep any undue strain from legs and mounting hardware If possible use a pallet or lift jack instead of tilting the unit NOTE please insta...

Страница 28: ...y regulating the feet until you reach the desired cooktop height Fix the components B to the ground according to widthY see below chart 24 30 36 48 Y 22 9 16 28 35 64 34 17 32 46 17 32 Insert the comp...

Страница 29: ...lumber or gas service company Burner caps are packed in styrofoam top pack with the grates Place burner on top of range Place burner grate on top of burner cap and grate support All stainless steel bo...

Страница 30: ...For all gas ranges only OFF Closed position from MIN to MAX 300 500 F Oven temperatures Broil Broil For all gas ranges only Griddle OFF Closed position from 1 to 7 positions Griddle temperatures For...

Страница 31: ...te to CUSTOMERCARE TECNOSPA IT Record the information indicated below You will need it if service is ever required The model and serial number can be found by looking in the last page of this booklet...

Страница 32: ...de or regulation 5 Damages due to failure in following the manufacturer s recommended care cleaning and maintenance instructions in particular damages to the oven and or the worktop if they have not b...

Страница 33: ...33 Electric diagram 24 30 4 burners all gas ranges...

Страница 34: ...34 Electric diagram 36 6 burners all gas ranges...

Страница 35: ...35 Electric diagram 36 4 burners and griddle all gas ranges...

Страница 36: ...36 Electric diagram 48 4 induction areas electric griddle and 2 gas burners...

Страница 37: ...37 Electric diagram 48 6 gas burners and electric griddle all gas ranges...

Страница 38: ...38 Electric diagram 30 4 burners dual fuel s c ranges Worktop Oven...

Страница 39: ...39 Electric diagram 36 6 burners dual fuel s c ranges Worktop Oven...

Страница 40: ...40 Electric diagram 48 6 burners and electric griddle dual fuel s c ranges Worktop Main Oven...

Страница 41: ...ck AWG 18 Blu e A WG18 White AWG 18 Blu e AWG18 White 1 2 3 4 L1 N AWG18 White AWG18 Green TERMOSTAT SIGNAL LAMP R T TOP HEATING ELEMENT BROILER HEATING ELEMENT R Bottom BOTTOM HEATING ELEMENT THERMAL...

Страница 42: ...42 Electric diagram 30 36 48 dual fuel s c ranges Oven...

Страница 43: ...1 42044 Gualtieri RE Italy T 39 0522 222 161 tecnogassuperiore tecnospa it appliances are proudly designed and handcrafted in Gualtieri Italy Tecnogas Tecnogas Superiore and Superiore are registered t...

Страница 44: ...superiore us superiore ca 461308626 rev 002 10 2017...

Отзывы: