VENTING INSTALLATION

Continued

FIRESTOP SPACERS (FS-10)

Firestop spacers are required at each point 

where the chimney penetrates a floor space. 

Their  purpose  is  to  establish  and  maintain 

the required clearance between the chimney 

and the combustible materials. When the pipe 

passes through a framed opening into a living 

space above, the firestop must be placed onto 

the ceiling from below as shown in Figure 12.

They also provide complete separation from 

one floor space to another or attic space as 

required by most codes. When the double wall 

pipe passes through a framed opening into an 

attic space, the firestop must be placed into an 

attic floor as shown in Figure 13.

Figure 12 - Firestop Spacer with Living 

Space Above Ceiling

Figure 13 - Firestop Spacer with Attic 

Space Above Ceiling

Existing 

Ceiling 

Frame

Firestop 

Spacer

Screws or 

Staples 

(Min. of 8)

Firestop 

Spacer

Screws or Staples 

(Min. of 8)

PENETRATING ROOF

To maintain a 2" clearance to the pipe on a 

roof with a pitch, a rectangular opening must 

be cut.

1.  Determine center point through which pipe 

will penetrate roof.

2.  Determine  center  point  of  roof.  Pitch  is 

distance the roof drops over a given span, 

usually 12". A 6/12 pitch means that roof 

drops 6" for each 12" measured horizon-

tally down from roof rafters.

3.  Use roof opening chart (Figure 14, page 

10) to determine correct opening length 

and flashing required.

4.  Remove shingles around opening mea

-

sured. Cut out this section.

Existing 

Ceiling 

Frame

Figure 11 - Typical Offset Terminations

Return 

Elbow

Offset 

Elbow

Return 

Elbow

Offset 

Elbow

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

Return 

Elbow

Offset 

Elbow

Offset 

Elbow

Return 

Elbow

A

B

C

Offset 

Elbow

Ceiling 

Support Pipe

12S-12DM

Return 

Elbow

Содержание WRT4842RH

Страница 1: ...ome USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other g...

Страница 2: ...ireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS fireplace and its components are safe when installed according to this installation manual Unless you use IHP compon...

Страница 3: ...O COMBUSTIBLE MATERIAL ON FACE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 66 X 20 2 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL 42 23 1 2 25 1 8 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17...

Страница 4: ...MATERIAL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0 TO BOTTOM OUTSIDE AIR 11 2 AIR SPACE BACK AND SIDES GAS LINE KNOCKOUTS 12 EACH SIDE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENS...

Страница 5: ...into consideration the following guidelines 1 The location must allow for proper clear ances see Figures 5 and 6 2 Consider a location where fireplace will not be affected by drafts air conditioning...

Страница 6: ...igure 5 WARNING Hearthextension is to be installed only as shown in Figure 4 MANTELS Amantel may be installed if desired see Figure 6 Woodwork such as wood trims mantels or any other combustible mater...

Страница 7: ...ons Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air In...

Страница 8: ...outer pipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upwa...

Страница 9: ...ing Figure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a...

Страница 10: ...OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashi...

Страница 11: ...n 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 18 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In a...

Страница 12: ...ry They should be positioned a distance apart as shown in Figure 20 4 Install rear refractory panel This panel has a top and bottom To determine which is which match up the pattern on the rear panel w...

Страница 13: ...d pull out insula tion from gas line conduit sleeve Save insulation for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve if usingaraisedp...

Страница 14: ...urning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the National Fuel Gas Code ANSI 7223NFPA 54 latest edition If you wish to install an unvented vent free gas log se...

Страница 15: ...al posi tion making sure top pins slide into door track Door is installed when top door pin snaps into spring clip 2 Repeat step 1 for remaining door If you find doors do not close properly or do not...

Страница 16: ...place and glass door retain their beauty and function properly Both the flue damper and glass doors mustbefullyopenedbeforestartingfire Thiswill provide sufficient combustion air and maintain safe tem...

Страница 17: ...ARTH PROD UCTS Homeowner s Guide included with your fireplace for proper fire building technique and ash removal procedures These fueling guide lines must be followed in order to achieve maximum emiss...

Страница 18: ...ified models are cleaner and pollute less than those models that have not met this emissions level Exposure to smoke has been associated with respiratory illness and other health problems Models that...

Страница 19: ...EPLACEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace part...

Страница 20: ...www SuperiorFireplaces US com 126604 01A 20 PARTS 42 AND 50 MODELS 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Страница 21: ...1 19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Scree...

Страница 22: ...www SuperiorFireplaces US com 126604 01A 22 PARTS MODELS 42 AND 50 Picture may vary from actual 1 2 5 3 4 6 6...

Страница 23: ...125833 01 Left Stacked 42 Natural White 1 125836 02 Left Herringbone 42 Red 1 125836 01 Left Herringbone 42 Natural White 1 125839 02 Left Stacked 50 Red 1 125839 01 Left Stacked 50 Natural White 1 1...

Страница 24: ...tinum BDG42B 42 Brushed Brass BD50 50 Black BD50P 50 Platinum BD50B 50 Brushed Brass DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND...

Страница 25: ...0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM COLLAR SC2 1 FIRESTOP SP...

Страница 26: ...cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance...

Страница 27: ...rmal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Страница 28: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Страница 29: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 30: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 32: ...126604 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126604 01...

Отзывы: