NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
14
Figure 13
Facing
1.
Combustible wall (such as drywall panels) must be installed fl ush
with the fi replace. It may not project in front of and on the fi replace
(i.e. the steel facade of the fi replace (
see
Figure 13
)
.
2.
Decorative frame made of combustible material cannot project in
front of and on the fi replace steel front, in the space delimited by
the width of the unit (38") and a height of 54" from the base of the
appliance (
see
Figure 15
)
.
3.
Non-combustible materials such as brick, stone or ceramic tile may
project in front of and onto the fi replace facing (
see
Figure 14
)
.
2" x 3" MIN.
*
54"
1/2" GYPSUMBOARD
SPACER
MANTEL
Figure 14
2" x 3" MIN.
SPACER
1/2" GYPSUMBOARD
NON
COMBUSTIBLE
FACING
Figure 15
Combustible cannot project over
or in front of the fi replace
38" (965mm)
54"
(1372mm)
Mantel
The mantel must be installed at least 54" (1372 mm) above the base of
the fi replace (
see
Figure 13
)
.
*NOTE:
Mantel can be reduced to 48" (1219 mm) if the Clean Face Panel
option is installed with the gravity kit.