Superior WRT4826WH Скачать руководство пользователя страница 14

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

14

Figure 13

Facing

1.

   Combustible wall (such as drywall panels) must be installed fl ush 

with the fi replace.  It may not project in front of and on the fi replace 
(i.e. the steel facade of the fi replace (

see 

Figure 13

)

.

2.

  Decorative frame made of combustible material cannot project in 

front of and on the fi replace steel front, in the space delimited by 
the width of the unit (38") and a height of 54" from the base of the 
appliance (

see 

Figure 15

)

.

3.

  Non-combustible materials such as brick, stone or ceramic tile may 

project in front of and onto the fi replace facing (

see 

Figure 14

)

.

2" x 3" MIN.

*

54"

1/2" GYPSUMBOARD

SPACER

MANTEL

Figure 14

2" x 3" MIN.

SPACER

1/2" GYPSUMBOARD

NON

COMBUSTIBLE

FACING

Figure 15

Combustible cannot project over 
or in front of the fi replace

38" (965mm)

54"

(1372mm)

Mantel

The mantel must be installed at least 54" (1372 mm) above the base of 
the fi replace (

see 

Figure 13

)

*NOTE:

  Mantel can be reduced to 48" (1219 mm) if the Clean Face Panel 

option is installed with the gravity kit.

Содержание WRT4826WH

Страница 1: ...ith an adjustable safety gate or barrier screen Wood Burning Fireplaces P N 900085 00 REV B 06 2016 WRT4826WH WRT4826WH This installation manual will enable you to obtain a safe efficient and dependab...

Страница 2: ...structionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING TheWRT4826WHfireplacemust be installed with an outside...

Страница 3: ...18 ACBI Chimney Installation Instructions Page 19 Offset Chimney Installation Page 20 Angled Wall Radiation Shield Page 21 Chimney Support Installation Page 22 Chimney Chase And Multiple Terminations...

Страница 4: ...tering the combustor have to be higher than 500 F 260 C That is why the unit is equipped with a by pass damper that allows the draft air to by pass the catalytic combustor Opening the by pass damper c...

Страница 5: ...ors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the WRT4826WH fireplace with the air control opened to produce a hot fire fo...

Страница 6: ...including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a man...

Страница 7: ...c tionsinthismanual orifthecatalyticelement is deactivated or removed Creosote When wood is burned slowly it produces tar and other organic vapors which combine with expelledmoisturetoformablackdeposi...

Страница 8: ...e combustor in a partially open and partially closed position after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause...

Страница 9: ...s deep in your firebox andwhenthefirehasburneddownand cooled removeexcessashes Leaveanashbed approximately1inchdeeponthefireboxbottom to help maintain a hot charcoal bed Remove ashes only when the fir...

Страница 10: ...e 9 Figure 8 Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO PEEL CAUTION DONOTALLOWWINDOWCLEANER TO GET IN CONTACT WITH DOOR GASKET OR PAINT ON FACADE OR...

Страница 11: ...The WRT4826WH fireplace may be installed directly on a combustible floor The supplied safetymetalstripmustbepositionedasfollows One half under the front of the fireplace and the otherhalfmustextendon...

Страница 12: ...llustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allf...

Страница 13: ...bustibles around chimney components required NOTE Blown or fill type insulation materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcod...

Страница 14: ...t 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Figure 14...

Страница 15: ...68 1727 mm Maximum length See Figure 17 The height of the louver must be measured fromthebaseoftheWRT4826WHfireplace to the middle point of the louver When installing the double outlet system the hota...

Страница 16: ...the hot air ducts to a central heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for...

Страница 17: ...he basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other...

Страница 18: ...tional Ltd 7 diameter chimney systems models ACBI or ASHT or S2100 or DuraVent model DuraTech DTC chimney systems NOTE Use of ACBI chimney with these fireplaces require the use of a starter section us...

Страница 19: ...20 feet and at the roof level installauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 22 4 Puttheroofflashing...

Страница 20: ...h together It is recommended to use three 3 metalscrews Ifpenetratingawall use a wall radiation shield 3 Use another elbow to turn the chimney vertically ACBI Lock it to the chimney Fastenthestrapsatt...

Страница 21: ...8 mm Chimney 7 Elbow Deviation Length ONE LENGTH BETWEEN ELBOWS TWO LENGTHS BETWEEN ELBOWS 8 12 18 24 36 48 8 36 12 48 18 48 24 48 36 48 Secure Temp ASHT DuraTech DTC 15 Deviation 3 5 16 84 mm 4 5 16...

Страница 22: ...lightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2...

Страница 23: ...e ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry ch...

Страница 24: ...mney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES Projet Nova Temp HT6000 is equivalent to S2100 Projet Nova Temp HT61...

Страница 25: ...adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF Thermopile gauge and label replacement J8004 CLEARANCE TO COMBUSTIBLES The following clearances m...

Страница 26: ...alling ACBI Chimney Starter Section w Air Intake 7 Dia ACBI7SBA ACBI7SBA Offset Starter Section 30 7 Dia ACBI7SBA30 ACBI7SBA30 Outside Air Kit The following components are required if installing ACBI...

Страница 27: ...R Storm Collar 7FC 7FC DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Len...

Страница 28: ...ry Chimney Masonry Chimney Adaptor 45 BISPMA CANADA ONLY BISPMA 30 Adaptor for Masonry Chimney BISPMA30 BISPMA30 SECURITY CHIMNEYS PARTS AND COMPONENTS LISTS The components listed below must be ordere...

Страница 29: ...use with approved fuels listed in the Operation Manual provided with the product This includes burning such replace fuels as wood and natural or propane gas Fuel products with abnormal burning charac...

Страница 30: ...PARTS See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shippe...

Отзывы: