Superior WCT4820WS Скачать руководство пользователя страница 25

(AC) Air-Cooled Chimney System*

 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior

AC Starter Adaptors

One of the following adaptors is required 

if installing an AC chimney system

* AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates 

(climates where temperatures will fall below 32° F / 0° C). 

Description

Cat./Part No.

Starter Section (adaptor), 6”, AC, AC6SB

H3779

Starter 30º Elbow, 6” AC, AC6SB30

H3780

The following outside air kit is required if installing an AC chimney system

Chimney Outside Air Kit (flex, insulation, outside register 

and coupling), ACZI

H1967

Lengths and Misc. Chimney Components 

12” Length, 6” Dia. x 12” Long, AC6L12

H0472

18” Length, 6” Dia. x 12” Long, AC6L18

H0473

36” Length, 6” Dia. x 36” Long, AC6L36

H0474

48” Length, 6” Dia. x 48” Long, AC6L48

H0475

15º Elbow, 6” Dia., AC6E15

H0476

30º Elbow, 6” Dia., AC6E30

H0477

Rain Termination Cap, 6” Dia., AC6CPR

H0478

Spark Arrester Screen (universal spark arrester band), PE

PE

Wall Band, XBM

XBM

Supports

Offset Support, SO

SO

Support Section, AC6SL

H0481

Roof Support, ST

ST

Roof Brace, BS2

BS2

Roof Flashings

Flat Roof Flashing, ACF

H0494

1/12 - 7/12 (5º - 30º), AC Adj. Roof Flashing, FA

H0495

8/12 - 12/12 (30º - 45º), AC Adj. Roof Flashing, FB

H0496

Storm collar, ACFC

H0500

Misc.

Telescopic attic radiation shield, ACRST 

H0498

Firestop, ACBF 

H0485

Radiation Shield, ACRS 

H0486

Attic Radiation Shield, ACRSA 

H0487

Insulated Wall Radiation Shield, 30º, ACRSMI30 

H0489

Tubinox

®

 LL Chimney  Lining System** 

Rigid Stainless Steel Liner For Relining A Masonry Chimney, 6” Diameter 

Listed to ULC-S635M, UL-1777 and ULC-S640M at 2100º F

Description

Cat./Part No.

6” Length, 6” Dia., 6LL6

6LL6

12” Length, 6” Dia., 6LL12

6LL12

24” Length, 6” Dia., 6LL24

6LL24

36” Length, 6” Dia., 6LL36

6LL36

48” Length, 6” Dia., 6LL48

6LL48

Adjustable Length (7” to 11”), 6” Dia., 6L7A

6L7A

Split Base Tee, 6” Dia., 6LT

6LT

Tee Cap, 6” Dia., 6TCS

6TCS

Twist Lock Tee Cap, 6” Dia., 6LTC

6LTC

Elbow 30º, 6” Dia., 6LE30

6LE30

Elbow 45º, 6” Dia., 6LE45

6LE45

Elbow 90º, 6” Dia., 6LE90

6LE90

Rain Termination Cap (regular), 6” Dia., 6LCS

6LCS

Rain Termination Cap (deluxe), 6” Dia., 6LCC

6LCC

Spark Arrester Screen (universal spark arrester band), PE

PE

Supports

Top Support, 6LST

6LST

Support Assembly, 6LSA

6LSA

Interior Support, 6LSB

6LSB

Adaptor Flexible Pipe (male), 6LAAM

6LAAM

Adaptor Flexible Pipe (female), 6LAAF

6LAAF

Stainless Steel Flex - five (5) feet Long, 6LLFLEX

6LLFLEX

Adjustable Insulated Wall Radiation Shield 6” - 12”, 6LRSMI

6LRSMI

Adaptors to Masonry Chimney

Masonry Chimney Adaptor, 45º, BISUMA 
(for use with 

Tubinox

 liner) CANADA ONLY

BISUMA

Masonry Chimney Adaptor, 30º, BISUMA30 
(for use with 

Tubinox

 liner)

BISUMA30

SECURITY CHIMNEYS™ - PARTS AND COMPONENTS LISTS

The components listed below must be ordered from Security Chimneys International™.  Contact your Security Chimneys Distributor or Dealer for ordering 

information.  

Security Chimneys International Limited
2125 Monterey, Laval, quebec
Canada, H7L 3T6
securitychimneys.com

450-973-9999
1-800-361-4909 (USA)
1-800-667-3387 (Canada)

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

7B26ZE90

Elbow 45º, 8” dia., 7B26ZE45

7B26ZE45

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

7B26ZLA

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

7B26ZL2A

Wall radiation shield, 8” I.D., 7B26ZR

7B26ZR

Black grill with support, 7B30ZO

7B30ZO

Brass grill (for 7B30ZK), 7B30ZGB

7B30ZGB

Length one (1) feet, 8KL1

8KL1

Length two (2) feet, 8KL2

8KL2

Length three (3) feet, 8KL3

8KL3

Length four (4) feet, 8KL4

8KL4

Length five (5) feet, 8KL5

8KL5

**  

Alternate brand rigid stainless liner or stainless flex may be substituted but 

must be listed to UL-1777 for US application and ULC-S635 for existing 

masonry or ULC-S640M for new masonry applications in Canada. The steel 

rigid or flex liner must be rated at 2100º F (1100º C).

25

Содержание WCT4820WS

Страница 1: ... Cert No 537 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Hot Do not touch The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli ance Severe burns may result Carefully supervise children in the same room as appliance If small children are present in the home it is recommended that this appliance be fitted with an...

Страница 2: ...e unat tended while it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operation nor are we respon sible for inadequate system draft caused by mechanical systems general construction conditions inadequate chimney heights adverse ...

Страница 3: ... fireplace installation consult the local authorities to obtain your buildingpermitandcheckyourlocalbuilding codes Installthefireplaceonlyasdescribed in these instructions and using only IHP components This fireplace has been tested for CAN ULC S610 M87 and ANSI UL 127 under report number 3011202 It has also been tested for EPA 40 C F R Part 60 section 60 532 b Certificate number 537 The WCT4820WS...

Страница 4: ...of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Hardwoods are preferred to softwoods since the energy content of wood is relative to its density Hardwoods will result in a longer burning fire and less fre quent refueling A moisture content of 15 to 20 seasoned is recommended Wood that has been cut and split and let to dry under a ...

Страница 5: ...dtoprovidesmoke free operation Occasionally there may be a smallamountofsmokinguponlightingthefire until the chimney heats up but this should not continue If the fireplace continues to smoke it is probably for one of the following reasons A Negative pressure in the house As the fire burns air goes up the chimney This air must be replaced through leakage intothehouseorthroughtheoutsideairduct When ...

Страница 6: ...o ensure that sparks and hot embers coming out of the chimney are not igniting the roof 6 Do not use the fireplace again until your chimney and fireplace have been inspected by a qualified chimney sweep or a Fire Department Inspector What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less than...

Страница 7: ...amic baffle 7 Remove the rear ceramic baffle To install the new refractories follow the above steps in reverse DOOR INSTALLATION The door must be installed only when the installation of the WCT4820WS fireplace is completed All you have to do is fit the male part of the hinge already on the door to the female part which is on the fireplace To remove the door simply pull the door up from the hinges ...

Страница 8: ...nal support is needed The WCT4820WS fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from the base of the appliance to the ceiling is required Whenselectingthelocation thechimneyoutlet positionandthedirectionofthewindareimpor tant factor affecting the chimney performance To allow a ma...

Страница 9: ...he fireplace mustbecoveredwithanon combustiblemate rial tile marble stone etc SeeFigures7and8 Cold climate INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performance of the appliance will vary depending upon the level of insulation house design how the appliance is operated etc If this fireplace is being installed in a cold climate it is especially important to seal...

Страница 10: ...nsions specifications colors and pricesaresubjecttochangeordiscontinu ance without notice All framing dimensions calculated for 1 2 dry wall at the fireplace face If sheathing the chase or finishing with other thickness materials calculations will need to be made Thefireplacemustnotbeincontactwith any insulation or loose filling material Cover the insulation with Drywall panels around the fireplac...

Страница 11: ...sed To Cover Chase Opening 8 Level 8 2 4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE Itisrecommendedthatthechase wallsandfloorbeinsulatedinthesame manner using the same insulation as the rest of the building below the attic SEE NOTE Nailing Flanges Four nailing flanges are provided to secure the fireplace to the floor see Figure 11 Bend the nailing flanges down so...

Страница 12: ...rd of the WCT4820WS fireplace not flush it will be necessary to purchase two adjustable lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom as the fireplace or one or both of the outlets can be installed in adjacent or upper rooms Installing the ducts at different elevations will tend to exhaust more heat out of the higher outlet Figure 15 Frame Gril...

Страница 13: ...t and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of the WCT4820WS fireplace allow the connection of insulated flexible pipe which enables you to heat adjacent rooms up to 50 feet from the fireplace The ducting system must be installed as de scribed below A Fix the adaptor at the back and ...

Страница 14: ...from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exhaust fumes gas meters and other vents E The duct and register may be installed above or below floor level The following components are required Outside air kit UZI includes 4 inch flex that goes up to ten 10 feet long 4 Adaptor for fir...

Страница 15: ...el WCT4820WS may be installed only with Security Chimneys International Ltd 6 diameter chimney systems 3 A chimney venting a fireplace shall not vent any other appliance 4 The minimum chimney height is 12 feet 3 7 m In altitude add 18 450 mm to the chimney for every 2 000 feet 600 m above sea level 5 All chimney installations must include at least one support The maximum length of chimney that can...

Страница 16: ...h roofing pitch see Figures 24 and 25 For sloping roofs place the flashing under the upper and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt supplied Finally seal the joint between the stormcollarandthechimney usingsilicone caulking 7 Install the chimney cap Once the chimney cap...

Страница 17: ...b bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop See Figure 23a 6 A support ST or SO must be used on the first 15 section 5 m 7 Continue with the regular installation AC Chimney 1 Install the first elbow Turn it in the required direction...

Страница 18: ...1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm 107 3 8 2727 mm 30 A 9 3 8 238 mm 12 3 8 314 mm 21 3 8 543 27 3 8 695 mm 32 5 8 829 mm 35 5 8 905 mm 44 5 8 1134 mm 50 5 8 1286 mm B 25 3 4 654 mm 31 787 mm 46 1 2 1181 mm 57 1448 mm 66 1676 mm 71 1 4 18...

Страница 19: ...1 1 8 x 30 3 4 45º 283 mm x 518 mm 11 1 8 x 20 3 8 S2100 HT6000 AC 6 dia 30º 327 mm x 881 mm 12 7 8 x 34 11 16 30º 380 mm x 972 mm 15 x 38 1 4 Table 5 Figure 30 Drywall Insulated Wall Insulated Wall Radiation Shield Figure 28 Offset Chimney Installation Figure 29 Insulated Wall Radiation Shield Support Straps ACRS Chimney AC Starter Section Straps Rain Cap Collar Roof Flashing Offset Support Frami...

Страница 20: ...with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY OFFSET SUPPORT ROOF SUPPORT ASHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m S2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNEY CHASE AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part of a building...

Страница 21: ...t Firestop Tubinox or Projet SS Stainless Steel Liner Insulated Length Masonry Chimney New or Existing Tubinox or Projet SS Liner Must Slide at Least 2 Inside Length 6 8 Available from Security Chimneys NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 21 INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION WARNING Before starting the installation the masonry chimney must be inspected by a qualified chimn...

Страница 22: ...able length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 Optional installation accessories uNot tested under EPA certification If installed this appliance no longer qualifies for EPA certification Check with local authorities having jurisdiction for requirements in your area vNot for sale in the US Fireplace Kits Descri...

Страница 23: ... PR SR2218 1 Snap disc blower VTU Bracket secondary air tube PR SR2214 Hinge assembly fireplace and door PR SR2395UL Door handle rod and mechanism PR SR2118 Door handle and brass cap PR SR2325 Door handle brass cap POIGNE002 Gasket door 73 5 8 dia PR SR1823G Gasket glass 69 5 16 dia PR SR1685D Blower 250 CFM for central forced air kit BISZY BISZY Blower variable speed control with decorative wall ...

Страница 24: ...teel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6L12 18 length 6 Dia 6L18 6L18 24 length 6 Dia 6L24 6L24 36 length 6 Dia 6L36 6L36 48 length 6 Dia 6L48 6L48 Adjustable Length 12 6 Dia 6LA 6LA 15º elbow 6 Dia 6E15 6E15 30º elbow 6 Dia 6E30 6E30 Rain Termi...

Страница 25: ...48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7A Split Base Tee 6 Dia 6LT 6LT Tee Cap 6 Dia 6TCS 6TCS Twist Lock Tee Cap 6 Dia 6LTC 6LTC Elbow 30º 6 Dia 6LE30 6LE30 Elbow 45º 6 Dia 6LE45 6LE45 Elbow 90º 6 Dia 6LE90 6LE90 Rain Termination Cap regular 6 Dia 6LCS 6LCS Rain Termination Cap deluxe 6 Dia 6LCC 6LCC Spark Arrester Screen universal spark arrester band PE PE Supports Top Support 6LST 6LST...

Страница 26: ...26 NOTES ...

Страница 27: ...normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cau...

Страница 28: ...rts See Page 23 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The d...