OPTIONAL EQUIPMENT

Blower Kits

The 

FBK-100 Blower Kits

 are used when 

a wall-mounted ON/OFF blower switch is 
desired, and the 

FBK-200 Blower Kits

 are 

used when a wall-mounted variable speed 
blower control (rheostat) is desired.  A 

Junction 

Box / Electrical Kit 

 is also required to install 

these kits (purchased separately - see 

Page 15

)

.

The blower is installed beneath the fi rebox.  
Room air is drawn in through the side slots 
of the fi replace, heated as it passes across the 
fi rebox, and discharged through the upper area 
of the fi rebox opening. 

The installation instructions for installing these 
blower kits are on 

Pages 12 through 14

.  Also 

see the installation instructions provided with 
the blower kits (Form #750028M).   For electrical 
requirements, refer to 

Figures 12, 13 and 14.

If the blower kit is to be installed at the time of 
installation or at a later date, the main power 
supply must be installed at the time of instal-
lation.  

This will require that the electrical 

connections must be made BEFORE the fi rebox 
is framed and enclosed in the fi nished walls.  

Route a 3-wire, 120 VAC, 60 Hz, 1 ph power 
supply and connect to electrical receptacle wires 
and wall switch or rheostat.

Grounded

to Appliance

Blower Motor

Motor Plug

Receptacle

120V

Appliance Junction Box

120V, 60HZ, 
1PH BLOWER 
CONTROL CIRCUIT 
WIRING

Junction 
Box

Factory Wired

Blower

Tab
Intact

Plug blower
into this 
receptacle

Ground - Green

* Wall-mounted ON/
OFF Blower Switch
or Variable Speed 
Control Switch.

Ground

HOT SIDE OF 
RECEPTACLE

*An ON/OFF Wall Switch is used with the FBK-100 kit 
(fi eld provided or sold separately - order P/N 85L87); A 
Variable Speed Control (provided) is used with the FBK-
200 kit.  The installation of these kits also require a 
Junction Box / Electrical Kit, not included. See 

Page 

15

 for ordering information.

NOTE: If any of the original wire as supplied must 
be replaced, it must be replaced with type AWM 105 
degree C - 14 gage wire. 

Neutral - White

120 V

AC Black

Green
Ground
Screw

NEUTRAL 
SIDE OF
RECEPTACLE

Black

Field Wired

Figure 14

Blower

* Junction Box

Bend blower mounting 
tabs up to secure 
blower in place

 

* Electrical Outlet

Tie a loose knot in power 
cord to take up slack

Top View

Figure 13

Figure 12

NOTE: 

If any of the original wire as supplied must 

be replaced, it must be replaced with type AWM 
105 degree C - 14 gage wire. 

* The Junction Box / Electrical Kit is not included. 
See 

Page 15

 for ordering information.

Figure 11

Hood

Side View

       

IMPORTANT

The 

Ground Lead 

  must be connected 

to the green screw (located on the 
junction box). Failure to do this 
could result in an electrical short or 
shock injury.    

The appliance must be electrically 
grounded in accordance with local 
codes or, in the absence of local 
codes, the national electrical code, 
ANSI/NFPA 70-latest edition. (In 
Canada, the current CSA C22.1 
Canadian Electrical Code).

       

CAUTION

Electrical connections should 
only be performed by a qualifi ed, 
licensed electrician. Main power 
must be off when connecting to 
main electrical power supply or 
performing service.

Содержание VRT2536WS

Страница 1: ...IONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED REFER TO COMBUSTI...

Страница 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...EGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2appr...

Страница 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used _________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the s...

Страница 5: ...ree firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WARNING D...

Страница 6: ...her on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and right clearances are determined when facing the front of the firebox Fo...

Страница 7: ...ltile etc ametal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance Models VRT2536WS and VRT2542WS WITH Hood Installed Hood is required on all instal...

Страница 8: ...owever and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be instal...

Страница 9: ...rface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the fireb...

Страница 10: ...2542WS 130 lbs 24 Cu Ft Fireplace Dimensions Model No A B C D E F G H J K L M N P Q VRT2536WS 36 914 24 610 41 3 4 1061 37 1 4 946 23 1 2 597 20 508 3 76 7 3 8 187 15 7 8 403 7 1 2 190 12 305 1 3 8 35...

Страница 11: ...frames as shown in Figure 11 Install three screws as shown in Figure 11 Make sure hood is level and secure Step 3 Reinstall screen and rod assemblies see Figure 10 Framing Dimensions Opening VRT2536W...

Страница 12: ...Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order...

Страница 13: ...see Figure 16 Step3 Looselytieaknotinthepowercordtotakeupslack seeFigure19 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seate...

Страница 14: ...se Figure 19 Figure 20 Figure 21 Loose knot in power cord to take up slack Firebox floor Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched...

Страница 15: ...l Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Volca...

Страница 16: ...Blower Variable Speed w wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I...

Страница 17: ...can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing prices at time of order NEVERUSESUBSTITUTEMATERIALS USEOFNON APPROV...

Страница 18: ...____________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________...

Страница 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Отзывы: