Superior VRT2536WS Скачать руководство пользователя страница 1

42" x 24" and 36" x 24" 
Universal Vent-Free Fireboxes
P/N  900853-00  REV. B  06/2017  

MODELS

UNIVERSAL VENT-FREE FIREBOX

INSTALLATION AND 
OPERATION INSTRUCTIONS

VRT2536WS

VRT2542WS

Due to high temperatures, the appliance should be located out 
of traffi c and away from furniture or draperies.

Do not place clothing or other materials on or near this appliance.

IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS 
COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM 
HEATERS.

FOR USE ONLY WITH A LISTED GAS-FIRED 
UNVENTED DECORATIVE ROOM HEATER NOT TO 
EXCEED 40,000 BTU/H.

DO NOT BUILD A WOOD FIRE.

WARNING: IMPROPER INSTALLATION, ADJUST-
MENT, ALTERATION, SERVICE OR MAINTENANCE 
CAN CAUSE INJURY OR PROPERTY DAMAGE. 
REFER TO THIS MANUAL. FOR ASSISTANCE OR 
ADDITIONAL INFORMATION CONSULT A QUALI-
FIED INSTALLER, SERVICE AGENCY OR THE GAS 
SUPPLIER.

Carefully review the instructions supplied with 
the decorative type unvented room heater for the 
minimum fi replace size requirement.  
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX 
UNLESS THIS FIREBOX MEETS THE MINIMUM 
DIMENSIONS   REQUIRED FOR THE INSTALLATIONS.

THIS IS A VENT-FREE GAS-FIRED HEATER ENCLO-
SURE.  IT USES AIR (OXYGEN) FROM THE ROOM 
IN WHICH IT IS INSTALLED. PROVISIONS FOR 
ADEQUATE COMBUSTION AND VENTILATION AIR 
MUST BE PROVIDED.  REFER TO COMBUSTION 
AND VENTILATION AIR SECTION, 

PAGES 3 AND 4

.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

FOR YOUR SAFETY:  Do not store or use gasoline 
or other fl ammables or liquids in the vicinity of 
this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

•  DO NOT light any appliance.
•  DO NOT touch any electrical switches.
•  Do not use any phone in your building.
•  Immediately call your gas supplier from a
    neighbor’s phone. Follow your gas suppliers 
 instructions.
•  If your gas supplier cannot be reached, call
  the fi re department.

Installation and service must be performed by 
a qualifi ed installer, service agency or the gas 
supplier.

WARNING: If the information in this manual is 
not followed exactly, a fi re or explosion may 
result causing property damage, personal injury 
or loss of life.

In the Commonwealth of Massachusetts:

  Installation must be performed by a licensed plumber or 

gas fi tter;

•  See Table of Contents for location of additional Common-

wealth of Massachusetts requirements.

US

Report No. F14-168

P900853-00

Содержание VRT2536WS

Страница 1: ...IONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED REFER TO COMBUSTI...

Страница 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...EGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2appr...

Страница 4: ...the maximum BTU Hr the space can support with the actual amount of BTU Hr used _________ BTU Hr max the space can support _________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the s...

Страница 5: ...ree firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WARNING D...

Страница 6: ...her on the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and right clearances are determined when facing the front of the firebox Fo...

Страница 7: ...ltile etc ametal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance Models VRT2536WS and VRT2542WS WITH Hood Installed Hood is required on all instal...

Страница 8: ...owever and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be instal...

Страница 9: ...rface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the fireb...

Страница 10: ...2542WS 130 lbs 24 Cu Ft Fireplace Dimensions Model No A B C D E F G H J K L M N P Q VRT2536WS 36 914 24 610 41 3 4 1061 37 1 4 946 23 1 2 597 20 508 3 76 7 3 8 187 15 7 8 403 7 1 2 190 12 305 1 3 8 35...

Страница 11: ...frames as shown in Figure 11 Install three screws as shown in Figure 11 Make sure hood is level and secure Step 3 Reinstall screen and rod assemblies see Figure 10 Framing Dimensions Opening VRT2536W...

Страница 12: ...Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE An ON OFF Wall Switch is used with the FBK 100 kit field provided or sold separately order...

Страница 13: ...see Figure 16 Step3 Looselytieaknotinthepowercordtotakeupslack seeFigure19 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seate...

Страница 14: ...se Figure 19 Figure 20 Figure 21 Loose knot in power cord to take up slack Firebox floor Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched...

Страница 15: ...l Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Volca...

Страница 16: ...Blower Variable Speed w wall mounted switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I...

Страница 17: ...can be found on the page Normally all parts should be ordered through your distributor or dealer Parts will be shipped at prevailing prices at time of order NEVERUSESUBSTITUTEMATERIALS USEOFNON APPROV...

Страница 18: ...____________________________________________ _____________________________________________________ _____________________________________________________ _______________________________________________...

Страница 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 20: ...make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information NO...

Отзывы: