NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

7

Figure 12

White
(Supply)

Black
(Supply)

Bipolar
Terminal
Screw

Blower
(Lower)
Outlet

Black
Wire

Mating
Connectors

Red Wire

120 Vac
 60 Hz

Blower Wiring Diagram

}

OFF/ON Blower

Wall Switch

To Fuse or
Circuit Breaker

120V

AC

60Hz

Fireplace
Junction Box

Black

White

Receptacle

Ground Wire
Connection

Note:  Supply wires may be alternatively connected to the outlet using the screw terminals,
however the black supply wire must be ganged wired to the same terminal that the pre-wired black
wire is attached to and the white supply wire must be connected to the opposite side of the outlet.

Step 5. Installing the Optional Remote Wall
Switch (VF4000-CMN/P models only) – 
The
millivolt system comes from the factory wired
as shown in 

Figure 10.  Select a convenient

location for the remote wall switch and connect
the wiring to the appliance (

Figure 11 ).

CAUTION:  DO NOT CONNECT THE OPTIONAL
REMOTE SWITCH TO A 120V POWER SUPPLY.

Note: The optional rocker switch is mounted to
the appliance and wired in the same way as the
remote wall switch.

Figure 11

Step 6. Installing the Optional Forced Air
Blower Kit Wiring –
 A receptacle plate is
provided for the installation of the FAB-1100
forced air blower kit (optional).  Electrical
power must be provided to this plate to oper-
ate the blower.

Route a 3-wire, 120Vac power line with con-
trol switch to the lower left front corner of the
appliance. Supply wires are to be connected to
the outlet as shown in 

Figure 12, ensuring that

the polarity (as determined by the colors of the
wires) is exactly as shown.  The black and red
wire loop must be left intact, with the mating
connectors connected.

Figure 10

VF4000-CMN/P Series

Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it
must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

* For Rocker or ON/OFF Wall Switch Attachment Only.

*

*

From Thermocouple

VF4000-CMN/P Series

Optional Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it
must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

Optional ON/OFF

Wall Switch/Rocker Switch

Factory Wired

Field Wired

*

* For Rocker Switch Attachment Only.

*

From Thermocouple

A. Light the appliance (refer to safety and
lighting instructions on pages 14 and 16).

B. Brush all joints and connections with the
gas leak test solution to check for leaks. If
bubbles are formed, or gas odor is detected,
turn the gas control knob to the “OFF” posi-
tion.  Either tighten or refasten the leaking
connection and retest as described above.

C. When the gas lines are tested and leak free,
be sure to rinse off the leak testing solution.

D. When the gas lines are tested and leak free,
observe the individual tongues of flame on the
burner. Make sure all ports are open and
producing flame evenly across the burner. If
any ports are blocked, or partially blocked,
clean out the ports.

An external regulator must be used on all pro-
pane (L.P.G.) heaters, in addition to the regula-
tor fitted to the heater, to reduce the supply tank
pressure to 13" w.c. (maximum).

WARNING: CONNECTING DIRECTLY TO
AN UNREGULATED PROPANE TANK CAN
CAUSE AN EXPLOSION.

Содержание VF4000-CHN-2 and

Страница 1: ...IREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATIONS This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and...

Страница 2: ...e page 9 Optional Equipment page 10 Forced Air Kit page 10 Operation and Care page 11 Cleaning and Servicing page 11 Replacement Parts page 11 Accessories Components page 12 Appliance Specifications p...

Страница 3: ...ft 3 per 1 000 BTU Hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicat ing directly with the space in which the appli ances are installed through...

Страница 4: ...above these appliances should be positioned just above the appliance top spacers The minimum height from the base of the VF4000 to the underside of com bustible materials used to construct a utility s...

Страница 5: ...Thefollowingstepsrepresentthenormal sequence of installation Each installation is unique however and might require a different sequence CAUTION HEATERSCREATEWARMAIRCUR RENTS THESE CURRENTS MOVE HEAT...

Страница 6: ...canresultincorrosionovertime Never use an open flame to check for leaks Figure 4 37 940mm 15 1 2 394mm Outside Wall Back Wall of Chase Enclosure Including Finishing Materials If Any Figure 5 37 940mm...

Страница 7: ...gure 12 ensuring that the polarity as determined by the colors of the wires is exactly as shown The black and red wire loop must be left intact with the mating connectors connected Figure 10 VF4000 CM...

Страница 8: ...hejunctionbox cover plate Failure to do so will prevent the appliance from operating The appliance must be electrically grounded in accordance with local codes or in the absence of local codes the Nat...

Страница 9: ...d 16 Note Instructions are also found on the pull out panel located on the bottom surface of the appliance Figure 16 Figure 18 Standard Manual Version Shown After setting the logs into position as des...

Страница 10: ...ive illustrations The appliances covered in this manual are heater rated and produce a great deal of heat Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater op...

Страница 11: ...it should be installed along with the appliance Refer to Figure 11 andStep5fordetailedinstallationinstructions Rocker Switch Kit An optional rocker switch kit can be installed directly on VF4000 CMN P...

Страница 12: ...as Flex Line Kit FFGC Refractory Liner Kit VF5RLK Decorative Volcanic Stone FDVS Wood Surround Wall SUR 5PW Wood Surround Corner SUR 5PC Brass Louver Kit BRLK 5C BSK 5 Brass Surround Kit BRLK CS Squar...

Страница 13: ...940 mm 36 914 mm 30 762 mm 31 1 2 800 mm 15 381 mm Front View Left Side View Right Side View Opposite Gas Line Opening J Box Opening 8 203 mm 3 3 4 95 mm 3 1 2 89 mm Top View 27 686 mm 36 914 mm 15 1...

Страница 14: ...e failure detector from shutting off the gas while the probe is warming up 10 Release the control knob while turning counterclockwise to the HI or LOW Position If the knob does not pop out when releas...

Страница 15: ...E DIAGRAMS ILLUSTRATION NOT TO SCALE 15 Figure 22 Pilot Location Figure 23 Pilot Turn Control Knob to OFF Position Figure 24 Turn Control Knob to IGN Position O F F I G N L O W H I O F F I G N L O W H...

Страница 16: ...STOP Read the safety information above on this page 2 Access left side louver 3 Turn remote wall switch to OFF 4 Verify main line shut off valve is open 5 Push in gas control knob slightly and turn c...

Страница 17: ...orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation SFC recommends running the heater with excess ventilation for the first few hours Turn control knob to LO...

Страница 18: ...0345 1 110344 1 Pilot Propane LPG 110341 1 901915 1 4 Regulator Natural 110351 1 903218 1 Regulator Propane LPG 110352 1 112081 1 5 Front Burner 110281 1 110281 1 6 Rear Burner Natural 113301 1 113301...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS 9 10 15 14 4 7 6 5 12 1 12 13 13 2 8 3 CH Models CM Models CH Models CM Models SIT Valve Shown 11...

Страница 20: ...03590 REV N 12 2007 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult...