Figure 17 - Optional Blower Wiring Diagram
INSTALLATION
Continued
HEAT DEFLECTIVE HOOD
INSTALLATION
The factory supplied heat deflective hoods
must be installed inside the fireplace opening
on both sides for the safe operation of the unit
as shown in Figure 18.
1. Remove protective covering from
hoods.
2. Position deflective hood into opening
on one side of the firebox and secure
to the top of the opening using screws
provided.
3. Secure the ends of the hood to the firebox
using two screws (provided) for each
side.
4. Repeat steps 2 and 3 to install hood on
the opposite side of the firebox.
CAUTION: Do not clean hood
with abrasive cleanser. Use only
regular household cleaners and
a smooth cloth.
Figure 18 - Typical Hood Installation
(Both Sides)
2 Screws Each
End of Hood
Corner
Post
Front Hood
(Typical Each Side)
3 Screws
(Top)
INCOMING
120V AC
(FUSE BOX
OR
BREAKER)
BLK
BLK
GRN
GRN
WHT
WHT
FIELD WIRE
GND
CONNECTORS
(NOT SUPPLIED)
VARIABLE
SPEED
CONTROL
BLOWER
RECEPTACLE
ELECTRICAL RATING:
120v, 60Hz, 0.9A
Note:
If any of the original wire must be replaced, it must be
replaced with type TEW minimum 16GA copper wire rated at 105°C