Superior SSDV-35 Series Скачать руководство пользователя страница 3

3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

CONGRATULATIONS!

In selecting this SUPERIOR Direct-Vent Gas Appliance you have chosen the fi nest and 
most dependable fi replace to be found anywhere.  A beautiful, prestigious, alternative 
to a wood burning fi replace.  Welcome to a Family of tens of thousands of satisfi ed 
SUPERIOR Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay 
special attention to the safety instructions provided in this manual.  The Homeowner's 
Care and Operation Instructions included here will assure that you have many years of 
dependable and enjoyable service from your SUPERIOR product.

The Electronic appliances have an electronic 
intermittent pilot system provides safe, effi cient 
operation. External electrical power is required 
to operate these appliances.

These appliances comply with National Safety 
Standards and are tested and listed by Omni-Test 
Laboratories (Report No. 116-F-29-5) to ANSI 
Z21.88b-2003 (in Canada, CSA-2.33b-2003), 
and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas fi replace heaters.

The Installation must conform to local codes 
or, in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
54-latest edition, or the Natural Gas and 
Propane Installation Code, CSA B149.1-latest 
edition.  The appliance, when installed, must 
be electrically grounded in accordance with 
local codes or, in the absence of local codes, 
the latest edition of the National Electrical Code, 
ANSI/NFPA 70, or the Canadian Electrical Code, 
CSA C22.1 - latest editions.

GENERAL INFORMATION

Note: 

Installation and repair should be per-

formed by a qualifi ed service person. The 
appliance should be inspected annually by a 
qualifi ed professional service technician. More 
frequent inspections and cleanings may be 
required due to excessive lint from carpeting, 
bedding material, etc.

It is imperative that the control compartment, 
burners and circulating air passage ways of  
appliance be kept clean.

S'assurer que le brùleur et le compartiment des 
commandes sont propres.  Voir les instructions 
d'installation et d'utilisation qui accompagnent 
l'appareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front openings of the appliance.

These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels or combination of fuels will degrade the 
performance of this system and may be dan-
gerous.

 Input (BTU) Manually-Modulated Gas 

Valves (millivolt models)

NATURAL GAS

Models

Input Rate

(BTU / HR)

SSDV-3530CNM

23,000 high

17,500 low

SSDV-4035CNM

29,000 high

21,500 low

Table 1

 Input (BTU) Manually-Modulated Gas 

Valves (millivolt models)

PROPANE GAS

if  unit was fi eld converted 

Models

Input Rate

(BTU / HR)

SSDV-3530CPM

23,000 high

17,500 low

SSDV-4035CPM

29,000 high

22,500 low

Table 2

Electronic Models with Fixed Rate Gas Valve

Natural and Propane Gas

Model Series

Input Rate

(BTU / HR)

SSDV-3530

23,000 

SSDV-4035

29,000 

Table 3

TABLE OF CONTENTS

Safety & Warning Information ..........Page  2
Introduction ......................................Page  3
General Information ..........................Page  3
Gas Controls Access .........................Page  4
Operation / Care of Your Appliance ...Page  5
Variable Flame Adjustment ................Page  5
Maintenance ......................................Page 

6

Front Glass Enclosure Panel,
  Removal and Installation .................Page  7
Install  Volcanic Stone,
Embers & Logs .................................Page  8
Burner Flame Appearance & Sooting Page  11
Burner Flame Adjustments ................Page  11
Millivolt Appliance Checkout .............Page  12
Electronic Appliance Checkout ..........Page  12
Wiring Diagrams ...............................Page  13
Warranty ...........................................Page  13
Product Reference Information .........Page  13
Accessory Components ....................Page  14
Lighting Instructions – Millivolt ........Page  17
Lighting Instructions – Electronic .....Page  19
Maintenance Schedule ......................Page  21
Troubleshooting Guide – Millivolt .....Page  22
Troubleshooting Guide – Electronic ..Page  22
Replacement Parts List .....................Page  24

INTRODUCTION

The Fireplace models covered in this manual 
are Direct-Vent sealed combustion gas fi replace 
heaters designed for residential application.  
Direct-Vent appliances operate with the com-
bustion chamber completely isolated from the 
indoor environment.  All air for combustion is 
brought in from the outside and  exhaust gases 
are vented through the same direct vent, co-axial 
(intake/exhaust) vent system.

The Millivolt appliances have a millivolt gas 
control valve with piezo ignition system provides 
safe, effi cient operation. If any optional acces-
sories which require electrical power are being 
installed, the electrical power must be provided 
at the time of appliance installation.

These fi replaces are designed as supplemen-
tal heaters. Therefore, it is advisable to have 
an alternate heat source when installed in a 
dwelling.

These appliances are designed to operate on 
natural gas or propane gas only. The use of 
other fuels or combination of fuels will degrade 
the performance of this system and may be 
dangerous.

Millivolt Models - BTU Input

Millivolt  models come standard with the manu-
ally-modulated gas valve; fl ame appearance and 
heat output can be controlled at the gas valve. 
The BTU Input for millivolt models is shown in 

Tables 1 & 2

:

Electronic Models - 

Electronic models have a fi xed rate gas valve.
The BTU Input for electronic models is shown 
in 

Table 3:

Содержание SSDV-35 Series

Страница 1: ...ONMAYRESULTCAUSINGPROPERTYDAMAGE PERSONAL INJURY OR LOSS OF LIFE POUR VOTRE S CURIT Ne pas entreposer ni utiliser d essence ni d autre vapeurs ou liquides inflammables dans le voisinage de cet apparei...

Страница 2: ...is manual For assistance or additional information consult a qualified installer service agency or the gas supplier SAFETY WARNIING INFORMATION WARNING Thesefireplacesareventedheat ers Do not burn woo...

Страница 3: ...Manually Modulated Gas Valves millivolt models NATURAL GAS Models Input Rate BTU HR SSDV 3530CNM 23 000 high 17 500 low SSDV 4035CNM 29 000 high 21 500 low Table 1 Input BTU Manually Modulated Gas Val...

Страница 4: ...may take a few hours or a few days KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTO...

Страница 5: ...neywell Millivolt Gas Valve Figure 5 O N OFF P I L OT L O H I OFF ON OFF ON Figure 3 Optional Blower OFF ON Rocker Switch SIT Millivolt Gas Valve Gas Outlet Gas Inlet Pilot Adjustment Screw Terminals...

Страница 6: ...rer see Page 24 for ordering information Re Install Embers Logs and Volcanic Stone Carefully follow placement instructions on Pages 8 to 10 All logs should fit onto cor responding pins and or log stop...

Страница 7: ...iance checkout and adjust ment period a potential safety hazard exists EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposedflamesorhotsurfaces Alsonote that while t...

Страница 8: ...per combustion could occur and result in soot and or excessive production of carbon monoxide CO a colorless odorless toxic gas INSTALL VOLCANIC STONE GLOWING EMBERS AND LOGS 1 Remove front glass enclo...

Страница 9: ...nhere 1through5 andpertheinstructionsonPage8 A Notch Notch 2 C 3 Notchesonbottomoflog C fitsover2locatingbrackets Topforkonlog B fitsintonotchonlog A B A 4 D A 5 Topforkonlog D fitsintonotchonlog A Pl...

Страница 10: ...1through5 andpertheinstructionson Page8 D A 4 A Bottomoflog B restsonsubfloor B Topforkonlog D fitsintonotchonlog A asshown Topforkonlog B fitsintonotchonlog A as shown 1 Place Embers and Volcanic St...

Страница 11: ...ance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your i...

Страница 12: ...couple Thermopile Pilot Nozzels SIT MILLIVOLT PILOT ASSEMBLY 3 8 Min 9 mm Igniter Rod Hood Proper Pilot Flame Appearance Figure 13 Proper Pilot Flame Appearance Thermocouple Thermopile Pilot Nozzels 3...

Страница 13: ...ttacheddirectlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type A...

Страница 14: ...ontrol transmitter The Model RCL T Deluxe remote control system is installed in the same manner as the standard system may be operated with electronic and mil livolt systems with either natural gas or...

Страница 15: ...These kits can be retrofitted to previously installed appliances ref Form 750 166M Door Frame Kits A decorative door frame kit is available for use with these appliances It is designed to attach dire...

Страница 16: ...the touch up paint kit TPK C ref Form 504 216M PA I N T ref Form 750 147M 4 Piece Trim Kit Cat No ModelNo Description 96K17 TK35PB4 35 4 Piece Finish Trim Kit Polished Brass SSDV 3530 96K18 TK40PB4 40...

Страница 17: ...in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair may result in a fire...

Страница 18: ...un commutateur lectrique Ne vous servez d aucun t l phone dans votre difice Appelezimm diatementvotrecompagniedegazenutilisantlet l phone du voisin S il vous est impossible de contacter votre compagni...

Страница 19: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 20: ...pour faire inspecter l appareil et remplacer toute pi cedusyst meder glageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mu...

Страница 21: ...eral runs too many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualif...

Страница 22: ...itch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote...

Страница 23: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 24: ...ls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 14 Gas Valve SIT 43K07 1 88J53 1 15 Piezo Igniter 91K94 1 91K94 1 16 Pilot Assembly 69L17 1 69L18 1 17 Pilot Generator 60J79 1 60J79 1...

Страница 25: ...25 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS DIAGRAMS 7 1 2 11 12 15 14 6 21 13 3 17 20 18 16 19 4 26 27 28 29 25 24 32 31 34 30 22 33 23 8 5 9 10...

Страница 26: ...26 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 28: ...reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace...

Отзывы: