![Superior SD23 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/superior/sd23/sd23_operators-manual_1402933002.webp)
IMPORTANT:
This manual contains specific cautionary statements relative to worker safety. Read this manual
thoroughly and follow as directed. It is impossible to list all the hazards of dust control
equipment. All persons involved with the equipment or systems should be instructed how to
operate in a safe manner.
CAUTIONS:
Avoid mixing combustible materials, such as buffing lint, paper, and wood with dust generated
from grinding ferrous metals due to the potential fire hazard caused by sparks in the table.
Under no conditions should cigarettes or any other burning object be put into the table.
All users of Superior Downdraft equipment should comply with all National and Local Fire
Codes and/or other appropriate codes when determining the location and operation of dust
control equipment.
This table is not suited for applications where explosion potential is present. Consult the Factory
to determine if there is a risk.
SPECIFICATIONS:
INPUT VOLTAGE: 120V 60Hz 1 Phase 208 / 230V 60Hz 3 Phase / 460V 60Hz 3 Phase
MAXIMUM CURRENT: 3HP 120V 24.6: Amps
3HP 208V: 7.8 Amps
,
230V: 8.6 Amps 460V: 4.3 Amps
5HP 208V: 13 Amps 230V: 12 Amps 460V: 6 Amps
MOTOR:
3HP 1 Phase 3450 RPM TEFC (SD34 ONLY) 3HP 3 Phase 3450 RPM TEFC (SD34 ONLY) 5HP 3Phase
3450RPM TEFC (SD46 ONLY) 7.5 HP 3Phase 3450RPM TEFC (SD48 ONLY)
AIR REQUIREMENTS:
1.1 SCFM at 80psi per second of cleaning pulse.
Minimum air line is 3/4”
Air Pressure regulated 80 – 90 psi.
Clean, dry, compressed air at the correct pressure is required for the cleaning system to
operate correctly. It is recommended that a pressure regulator and coalescing filter be
installed between the compressed air source and the inlet to the table.