A gas line or gas log lighter may be installed for the purpose of 

installing a vented or vent-free decorative gas appliance incorporat-

ing an automatic shutoff device and complying with the Standard 

for Decorative Gas Appliances for Installation in Vented Fireplaces, 

ANSI Z21.60 or American Gas Association draft requirements for 

Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 

dated August, 1993.
If  you  wish  to  install  an  unvented  (vent-free)  gas  log  set,  only 

unvented gas log sets which have been found to comply with the 

standard for unvented room heaters, ANSI Z21.11.2 are to be installed 

in this fireplace.
Gas line hook up should be done by your supplier or a qualified 

service person.

Note:

 Before you proceed, make sure your gas supply is turned off.

Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located above refractory hearth floor. Knockout indentation must 

be firmly tapped with any solid object, such as a 1/2" dowel, until 

it is released. Remove fragmented portions of refractory (see 

Figure 21).

2.  Remove gas line cover plate located on either side of fireplace and 

pull out insulation from gas line conduit sleeve. Save insulation 

for reuse.

3.  Run a 1/2" black iron gas line into fireplace through rear at 

gas line conduit sleeve (if using a raised platform, add height). 

Provide sufficient gas line into fireplace chamber for fitting 

connection (see Figure 22).

  Note: Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 

refractory cement or commercial furnace cement. Install gas 

appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 

ensuring that gas valve is on, apply soap and water 

solution to all connections and joints. Bubbles forming 

show a leak. Correct all leaks at once. DO NOT USE 

AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

Note: 

An IHP hood must be installed when using an unvented gas 

log set (see Accessories on page 18).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

Figure 22 - Gas Line Installation

OPTIONAL GAS LINE INSTALLATION

Figure 21 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

Содержание Merit WCT2036WS

Страница 1: ...papers This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to A...

Страница 2: ...warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component...

Страница 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxi...

Страница 4: ...5 21 125 0 TO BOTTOM OUTSIDE AIR LEFT SIDE ONLY TOP SPACERS 0 75 AIR SPACE BACK AND SIDES HEARTH EXTENSION 52 X 16 12 EACH SIDE NOT LESS THAN 14 TO PERPENDICULAR SIDEWALL 1 AIRSPACE TO COMBUSTIBLE COM...

Страница 5: ...and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be...

Страница 6: ...Drawing Not To Scale Safe Zone For Projection of Combustible Materials Combustible Material 12 Min 9 Min Fireplace Opening Top of Louvered Opening FIREBOX SAFE ZONE Figure 5 Side Mantel Clearance Top...

Страница 7: ...rical Cover Plate and Electrical Bushing Fireplace Chassis Ground To Power Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 7 Outsid...

Страница 8: ...first with lanced side up Outer pipe section can then be installed over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter Wire...

Страница 9: ...w 6 Max 6 Max 6 Max 6 Max 6 Max 6 Max Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Ceiling Support Pipe 12S 8DM Return Elbow Figure 10 Ceiling Support Pipe 12S 8DM 2 Min Straps Straps Str...

Страница 10: ...codes When double wall pipe passes through a framed opening into an attic space firestop must be placed into an attic floor as shown in Figure 13 Figure 12 Firestop Spacer with Living Space Above Cei...

Страница 11: ...snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney Pipe Wate...

Страница 12: ...ve shroud is to be installed contact manufacturer for specifications 24 Min 24 Min 18 Min Typ Figure 18 Multiple Chase Installation 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 10...

Страница 13: ...ement Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soa...

Страница 14: ...s and warranty informa tion please refer to your homeowner s guide or contact your dealer GLASS DOORS Glass doors are optional with this fireplace When fireplace is in operation doors must be fully op...

Страница 15: ...periorfireplaces US com REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product...

Страница 16: ...ww Superiorfireplaces US com 126628 01A 16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 29 19 2...

Страница 17: ...e Brick Liner 1 14 106972 01 Bottom Brick Liner 1 15 106973 01 Front Bottom Brick Liner 1 16 21198 Blower Access Plate 1 17 20027 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20...

Страница 18: ...24 8HT 36 8DM 36 8HT 48 8DM 48 8HT ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM 30 OFFSET AND RETURN 30E 8DM 30E HT ADJUSTABLE HOOD Antique Brass Finish GA6053 Black Painted Finish GA6050 Req...

Страница 19: ...RTT 8DM RTT 8HT RTTL 8DM AND RTTL 8HT ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RLTT 8DM RLTT 8HT SQUARE TOP TERMINATION WITH LOUVERS ET...

Страница 20: ...s specifica tions prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126628 01 Rev A 10 2013 P126...

Отзывы: