Installation
900004-00, 04/2014
Innovative Hearth Products
Superior™ DRT2000 and DRC2000 Direct-Vent Gas Fireplaces
40
19.
Install the Hood
NOTE:
All models must have a hood installed prior to operation.
1.
Install the hood by sliding it into the slots on the lower edge of the cabinet top.
NOTE:
To install the non-combustible finish material flush with the top of the hood, the hood must be installed
before installing the finish material. If finish material is installed flush with the top edge of the hood, the hood cannot
be removed.
NOTE:
To install the hood after installing the non-combustible finish material over the black surface above the
fireplace opening, the bottom edge of the finish material must be 5/8” above the top edge of the hood to allow
clearance for installation and removal of the hood.
20.
Reinstall the Included Barrier
WARNING
Reinstall any barrier removed before operating the fireplace. The barrier is designed
to reduce the risk of burns from hot glass. Do not operate the fireplace without the
barrier installed.
NOTE:
All models must have a barrier installed prior to operation.
1.
Open the control compartment door (
Page 50
).
2.
Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood.
3.
Slide the barrier bottom down into the slots below the glass door, securing it in place.
21.
Install the Finishing Materials
1.
Complete finished interior wall.
NOTE:
To install the fireplace facing flush with the finished wall, position framework to accommodate the thickness
of the finished wall.
Figure 41: Combustible Wall Framing
Top Of
Appliance
3”
(76 mm)
This Area
Must Remain
Clear of
Combustible
Materials
1” Min.
(25 mm)
3” Clearance
Minimum
Hood
Combustible
Material May
Touch The
Appliance
Top
Stand Off
Must Be Bent
To Vertical
Position
Combustible
Finished Wall
Materials
NOTE:
See
Cold Climate Insulation on Page 9
and
Vent Termination Clearances on Page 11
.
22.
Attach the Safety-in-Operation Warning Labels
1.
Attach the furnished safety instruction labels at all fireplace operation and control points (
Page 41
).
NOTE:
The installer MUST ensure these warnings are properly attached during installation. The warning labels are a
critical means of informing consumers of safe operation practices.