Superior BRT2032TMN Скачать руководство пользователя страница 16

SuperiorFireplaces.us.com

126745-01E

16

COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)
The outside air kit may be installed on the left side of the fireplace 

only. The vent can be installed through the outside wall or a ventilated 

crawl space. The handle to operate the damper door for the outside 

air inlet will be located inside the left “screen pocket” of the firebox 

(see Figure 28). Pull the handle to open or push to close.

 CAUTION: Air inlet ducts are not to terminate in 

attic space.

FIREPLACE INSTALLATION 

Continued

INSTALLING OPTIONAL GLASS DOOR ACCESSORY

 CAUTION: Use only glass doors certified for use 

with this appliance.

NOTE: Assistance with installation may be needed as glass doors 

are heavy.
These B-vent fireplaces are approved for use with optional bi-fold glass 

doors (see Accessories, Page 23). The glass panels may be ordered 

and installed anytime after the fireplace installation is complete.
Follow these steps to install left and right panels:
1.  With handle at the bottom, completely fold panel on its hinges.
2.  With handle facing center of firebox opening, insert lower pivot pin on 

glass door panel into hole in pivot plate on bottom edge of fireplace 

opening (see Figure 30).

3.  Keeping folded door tilted, slide upper two pins into the guide 

track found under upper facial edge of firebox opening.

4.  Tilt door assembly fully vertical until outer pivot pin snaps into 

mounting hole in upper spring clip (see Figure 30).

5.  Once top and bottom pins are secured, unfold door into closed 

position.

6.  Repeat process for opposite door assembly.

APPLIANCE ENCLOSURE
Before finishing enclosure around appliance, inspect all joints around 

outer surround. Any gaps between nailing flanges and framing should 

be sealed with noncombustible insulation or caulking (see Figure 29).
If appliance is mounted on a raised platform, it must be a continuous 

surface and not on blocks without a solid surface. This will prevent 

the entry of cold air by means of conduction through the total bot-

tom of the appliance.

7.  To adjust doors, slide them partially open. Using a screwdriver, 

loosen the hold-down screws in spring clip (see Figure 31, Page 

17) and pivot plate.

8.  Close both doors until evenly joined at the middle and note gap 

at outer edges of face.

9.  Reopen one door at a time and retighten upper and lower hold-

down screws.

10. Repeat process until both doors are evenly joined, spaced and 

working freely.

Figure 28 - Air Kit Handle Location

Air Kit 

Handle

Screen 

Pocket

Figure 29 - Sealing Between Appliance and Framing

Side 

Framing

Side 

Framing

Caulk Here

Pack Insulation

Figure 30 - Installing Optional Glass Door

Spring Clip

Insert Pin Into 

Spring Clip

Insert Bottom 

Pivot Pin 

Into Pivot 

Plate and 

Swing Door 

Into Vertical 

Position

Pivot 

Plate

Slide Top Pin Into 

Door Track

Содержание BRT2032TMN

Страница 1: ...I VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchez aucaninterrupteur Nepasvousservir des t l phones se trouvant dans le b timent o vous trouvez Sortez imm diatement de b timen...

Страница 2: ...so contains information that will enable you to obtain replacement parts or optional accessory items when needed Keep it with your other important papers State of Massachusetts The installation must b...

Страница 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Страница 4: ...ater installation The appliance and it s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 p...

Страница 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Страница 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Страница 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Страница 8: ...o cover any openings Prepare the incom ing gas line with Teflon tape or pipe joint compound and hookup incoming gas line to flexible gas line PRE INSTALLATION PREPARATION Continued NOTE If 1 2 NPT bla...

Страница 9: ...uirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M R Sections 4 00 through 8 00 Installation and repair must be done by a plumber or gas fitter lic...

Страница 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Страница 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Страница 12: ...e s gas sup ply system You may consider installing an extra gas shutoff valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a w...

Страница 13: ...nstallation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected and corrected Do no...

Страница 14: ...nder the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TMN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers see Figur...

Страница 15: ...top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fingers...

Страница 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Страница 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Страница 18: ...ndicator Gas Control Knob Pilot Adjustment Screw LIGHTING INSTRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be prese...

Страница 19: ...l knob to ON position Slide the selector switch to the REMOTE position NOTE Burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn burner on an...

Страница 20: ...ce off see To Turn Off Gas to Appliance Page 19 see Troubleshooting Page 21 Figure 36 Typical Flame Pattern BRT2332TMN BRT2532TMN Models BRT2032TMN Model WARNING Installation and repair should be done...

Страница 21: ...ossible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories Page 23 1 Check wiring...

Страница 22: ...tween control valve and burner 2 Gas leak See Warning statement at top of Page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive...

Страница 23: ...ete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time...

Страница 24: ...ces us com 126745 01E 24 PARTS MODEL BRT2032TMN 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 36 14 12 13 23 16 31 32 20 32 38 39 40 40 4 34 35 21 17 8 10 18 5 5 2 22 1 3 37 42 11 11 9 CATALOG NO MODEL F...

Страница 25: ...21 RP108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4373 Grate Assembly 1 24 J4308 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Pro...

Страница 26: ...6 PARTS BRT2332TMN AND BRT2532TMN MODELS 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 18 14 12 13 23 10 36 9 36 35 16 31 32 20 32 38 39 40 40 4 34 21 17 8 46 45 44 2 22 1 3 44 11 37 42 5 5 CATALOG NO MO...

Страница 27: ...108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4299 Grate Assembly 1 24 J4236 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Propane...

Страница 28: ...2 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on Page 23 of this manual KEY NO PART NO...

Страница 29: ...4 5 KEY NO PART NO DESCRIPTION QTY J4307 Log Set 1 J4339 Rear Log 1 2 J4338 Front Right Log 1 3 J4245 Front Left Log 1 4 J4244 Top Y Log 1 5 J4242 Top Log 1 WIRING DIAGRAM DO NOT CONNECT RED REPLACE F...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 32: ...ts Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126745 01 Rev E 02 2018 1769 East Lawrence Street Russellville AL 35654 SuperiorFi...