background image

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  CARE AND OPERATION INSTRUCTIONS

13

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

       WARNING 

Any safety screen or guard 

removed for servicing the appli-

ance must be replaced prior to 

operating the appliance.

       AVERTISSEMENT 

Tout écran ou protecteur retiré 

pour permettre l’entretien de 

l’appareil doit être remis en 

place avant de mettre l’appareil 

en marche.

       WARNING 

Do not operate appliance with 

the glass front removed, cracked 

or broken.

Front Glass Enclosure Panel Removal 

and Installation

To install the front glass door assembly, 

proceed as follows:

1.

 Retrieve the glass door assembly. Visually 

inspect the gasket on the backside of the 

panel. The gasket surface must be clean, 

free of irregularities and seated firmly.

2. 

Position the door frame in front of the firebox 

opening and engage the bottom flange over 

the rail at the bottom of the firebox opening.

3. 

Swing the door up and back. Ensure the 

gasket seats evenly as the door draws shut. 

Engage the nut insert and fasten with two 

screws to secure the door.

4. 

Install the door modesty shield on top flange 

glass door as follows: grab the door modesty 

shield with both hands, with the open hem 

going down and engage it with the upper lip 

of the glass door frame by pushing it all the 

way down. Make sure the installed shield is 

firmly in place.

5. 

With the firescreen hanging on the screen rod, 

drop in the right side of the rod to the right 

modesty panel. Then drop in the left side of 

the rod through the slot of the left modesty 

panel. Make sure that the rod is supported 

by the bracket in the center of the fireplace.

WHEN INSTALLING THE GLASS DOOR, 

SECURELY TIGHTEN THE LATCH SCREWS 

- SEE THE FIRST WARNING ON THIS PAGE.

When installing the glass door, ensure the 

spacing on both sides are equal.

Figure 9 - Front Glass Enclosure 

Panel

Top Flange Glass Door

Frame Assembly

Glass Door Latch (2)

Latch 

Screws

Firebox Floor

Glass Door Assembly

       WARNING 

• When  reinstalling  the  glass 

door, the door latch screws 

must be securely tightened 

to prevent the glass door 

from falling out, which could 

potentially cause damage and 

possible injury.

• Do not attempt to substitute the 

materials used on this door, 

or replace cracked or broken 

glass. 

• Handle this glass with extreme 

care! Glass is susceptible to 

damage - Do not scratch or 

handle roughly while reinstall-

ing the glass door frame.

• The  glass  door  of  this  appli-

ance must only be replaced 

as a complete unit as provided 

by the manufacturer. Do not 

attempt to replace broken, 

cracked or chipped glass sepa-

rately. 

• Do  not  attempt  to  touch  the 

front enclosure glass with your 

hands while the fireplace is in 

use.

       AVERTISSEMENT 

Ne pas utiliser l'appareil si le 

panneau frontal en verre n'est 

pas en place, est craqué ou 

brisé. 

Only doors certified with the appliance 

shall be used.

Seules des portes certifiées pour cet 

appareil doivent être utilisées.

WARNING: DO NOT abuse glass door by 

striking or slamming shut.

These are direct-vent appliances. They are 

designed to operate only when the front glass 

enclosure panel is installed. Generally the front 

glass enclosure panel should not be removed 

except to gain access to the components within 

the firebox. 

Removing Glass Enclosure Panel

(see 

Figure 9)

To remove the firescreens, lift up the center of 

the rod to disengage it from the center bracket, 

bend down at center, hold left side with hand 

until it disengages from left side, being careful 

not to scratch paint. Slowly remove the rod 

from the right side.

Remove the door modesty shield from the top 

flange glass door by pulling it up firmly with 

both hands until it is disengaged. Using a phillips 

screwdriver, unfasten two (2) screws located 

at the top of the glass frame.

Tilt the glass frame at the top away from the 

unit. Lift it carefully off the bottom door track 

and set the door aside, protecting it from 

inadvertent damage.

Содержание 40 Signature series

Страница 1: ...REN TO TOUCH GLASS UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D Y TOUCHER NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any...

Страница 2: ...tion 7 BTU Input 7 Gas Pressure Requirements 7 Orifice Sizes 7 Burn In Period 7 Operation and Care of Your Appliance 8 Gas Controls Control Compartment Access 8 Appliance Operation 8 Purge Cycle 8 Remote Control System 9 Lighting the Appliance 11 Power Vent Operation 11 Maintenance 12 Front Glass Enclosure Panel Removal Installation 13 Log Volcanic Stone and Glowing Ember Placement 14 Burner Adjus...

Страница 3: ...oir Page 5 Lisez la section Informations importantes relatives à la sécurité Page 4 Toutes les parties de votre foyer Innovative Hearth Products deviennent EXTRÊMEMENTCHAUDES Instale una malla o barrera física para evitar el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves Ver los detalles a la izquierda para ordenar un SAFETY GUARD GRATIS para su chimenea Siga las instru...

Страница 4: ...dultes peuvent subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaud...

Страница 5: ... les traces de graisse ou d huile Collez l étiquette sur la surface de la plaque du récepteur mural qui contrôle le foyer Figure A Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 2 Repérezlatélécommandeetnettoyez lasoigneuse ment pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur le boîtier de la télécommande Figure B Choisiss...

Страница 6: ... fireplaces are designed as decorative appliances and are not intended for use as area heaters They must not be equipped with wall thermostats or remote controls with thermostat functions CAUTION Hotwhileinoperation Donot touch Severe Burns may result Keep children clothing furniture gasoline and other liquids having flammable vapors away ATTENTION L appareil est chaud lorsqu il fonctionne Ne pas ...

Страница 7: ...CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR Flame breadth height and width will diminish 4 for every 1 000 feet of altitude Input BTU HR Natural Gas Model No Input BTU Hr 40 in 26 500 42 000 45 in 35 000 48 000 Table 1 BTU Input The BTU Input for these appliances is shown in Table 1 Gas Pressure Requirements Tables 2 and 3 show the appliances gas pressure requirements I...

Страница 8: ... others may be susceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraientêtresurveillésétroitementlorsqu ilssetrou ve...

Страница 9: ...to the gas valve coil and the appliance main burner turns on A single beep from the receiverwillconfirmreceptionofthecommand Turn OFF the Appliance Press the ON OFF Key on the transmitter The transmitterLCDdisplaywillonlyshowtheroom temperature and icon At the same time the receiver disconnects the gas valve coil and the appliance burner turns off A single beep from thereceiverconfirmsreceptionoft...

Страница 10: ...transmitter are low or depleted the appliance can be turned on manually by sliding the ON REMOTE OFF slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Transmission Set Point Temp Level State Flame On Child Safety Lock Out Low Battery Alarm Room Temperature Maximum Level Indica...

Страница 11: ...ing and pilot will light 4 Burner should light after a few seconds To turn ON the appliance with the remote transmitter 1 ManuallyslidetheON REMOTE OFFswitch totheREMOTEposition thenpresstheON OFF key on the transmitter 2 Blower should start immediately 3 Igniter starts sparking and pilot will light 4 Burner should light after a few seconds To Turn OFF 1 ManuallyslidetheON REMOTE OFFswitch to the ...

Страница 12: ...50 mix of white vinegar water Gas fireplace stove glass cleaner Inspect Glass Gasket Visuallyinspectthegasketonthebacksideofthe glassenclosurepanels Thegasketsurfacemust be clean free of irregularities and seated firmly Clean Control Compartment Keepcontrolcompartmentcleanbyvacuuming or brushing at least twice a year More frequent cleaning may be required due to excessive lint from carpeting beddi...

Страница 13: ...osure Panel Top Flange Glass Door Frame Assembly Glass Door Latch 2 Latch Screws Firebox Floor Glass Door Assembly WARNING When reinstalling the glass door the door latch screws must be securely tightened to prevent the glass door from falling out which could potentially cause damage and possible injury Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass Hand...

Страница 14: ...andpreventsooting Whenpositionedproperly as shown twigs will be positioned between flame peaks and will not impinge any flames WARNING DO NOT attempt to install the logs until the appliance installation has been completed the gas line connected and tested for leaks and the initial burner operation has been checked out The size and position of the log set was engi neered to give the appliance a saf...

Страница 15: ...Grate And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Align Hole At Bottom Of Log 5 Over The Pin On Log 2 6 5 7 2 Figure 16 Placing Logs 5 6 and 7 Engage Log 6 With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate Engage Log 7 With ...

Страница 16: ... termination Sooting is caused by incomplete combustionintheflamesandlackofcombustion air entering the air shutter opening To achieve a warm yellow orange flame with an orange body that does not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning to ensure that the flames are no...

Страница 17: ...o adjust the flame move the adjustment air shutter located on the lower venturi back or forward to increase or reduce the air shutter opening respectively Position the air shut ter to the factory setting as shown in Table 8 Allow the burner to operate for at least 15 minutes Observe the flame continuously If it appearsweakorsootyaspreviouslydescribed adjusttheairshutteruntiltheflameappearance is a...

Страница 18: ...is system please contact your dealer or distributor Innovative Hearth Products 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at www superiorfireplaces US com PRODUCT REFERENCE INFORMATION We recommend that you record the important reference information about your fireplace in the space provided below Please call Innovative Hearth Products for the phonenumberofyournearestInnovativeHearth...

Страница 19: ...mic and porcelain panels of the side and rear walls The ceramicpanelshavebrick likefeaturesinrelief Andiron Door Kit The andiron kit attaches to the grate assembly without the use of hardware Firebox Accessories Cat No Model Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers Ceramic and Porcelain Firebox Liner Kits Model Cat No Model Descr...

Страница 20: ...Screen Panel Kits These screen panel kits create a barrier to prevent direct contact with the hot glass The screen panel affixes directly to the front glass enclosure panel Log Set Cat No Description F1719 Aged Oak Logs Barrier Screen Kits Cat No Model Description H4805 BSK40 40 Barrier Screen H4806 BSK45 45 Barrier Screen Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40IN 2 40 Scre...

Страница 21: ...ese instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the fl...

Страница 22: ...tape suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du récepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour sélectionner ON 11 Si applicable Ajustez le thermostat sur la télécommande à l ajustement désiré 12 Si l appareil ne se met pas en marche suivez les instructions intitulées Comment couper l admission de gaz de l appareil et appelez un technicien qualifié ou le...

Страница 23: ...g exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this manual Replace Glowing Embers Homeowner Qualified Service Technician Remove old ember materials rockwool and vacuum the ember placement area Place new embers per instructions o...

Страница 24: ...n immediately goes out Gas is not reaching the fireplace Check the gas supply and gas shutoff valves call a service technician if required Loose wires to the valve or ignition module Check the gas supply and gas shutoff valves call a service technician if required Pilot flame is not engulfing the sensor Call a service technician Obstructed vent system Call a service technician Log and glass soot F...

Страница 25: ...e No Yes Check Position of Pilot Is Orifice Blocked No Replace Ignition Module No Does the Pilot Flame Cover the Flame Rod Is the Sensor Wire in Good Condition Is There Continuity to Ground from the Pilot Burner No Replace Control Module Does Pressure Switch Open During Operation Yes No Replace Ignition Module Yes Is Vent Partially Blocked Is There Water Dirt in Hose to Pressure Switch Are Hose Co...

Страница 26: ...9 1 10 Screen H1427 2 H1169 2 11 Gasket Access Plate H1452 1 H1452 1 12 Gas Line Tubing H2283 1 H2284 1 13 Connector Male H2285 1 H2285 1 14 Orifice Natural Gas H7924 1 H8141 1 15 Bag of Glowing Embers 88L53 1 88L53 1 16 Grate Assembly Traditional only H4907 1 H4907 1 17 Gas Line Flexible Connection 93L32 1 93L32 1 18 Modesty Panel Right Side H3371 1 H3372 1 19 Modesty Panel Left Side H3373 1 H337...

Страница 27: ...RODUCTS POWER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN CARE AND OPERATION INSTRUCTIONS 27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 23 15 21 22 7 17 13 12 6 8 11 10 9 5 1 4 16 3 20 19 18 25 24 14 Replacement Parts ...

Страница 28: ...8 H7375 Wrapper Top 1 19 H7373 Wrapper 1 20 H7374 Wrapper Bottom 1 21 H7377 Junction Box 1 22 H7379 Diverter Front 1 23 H7380 Diverter Back 1 24 H7376 Wrapper Cover 1 25 H7381 Wire Mesh 1 24 18 19 17 16 15 14 8 25 22 23 21 1 4 20 7 5 2 6 3 Printed in U S A 2013 Innovative Hearth Products LLC P N 506010 12 Rev NC 12 2013 Innovative Hearth Products reserves the right to make changes at any time with...

Отзывы: