background image

Printed in U.S.A. © 2007 by LENNOX HEARTH PRODUCTS

P/N  725,041M  REV.  A  02/2008

REPLACEMENT PARTS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

The manufacturer reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.

1110 West Taft Avenue
Orange, CA  92865

Models 36

Models 42

No.

DESCRIPTION

Part No.

Qty.

Part No.

Qty.

Gas Fireplace Assembly

1.

Firescreen

161136

2

161108

2

2.

Rod, Screen

88L95

2

88L95

2

3.

Refractory, Side

LB-96795

2

LB-96798

2

4.

Refractory, Rear

LB-96796

1

LB-96799

1

5.

Refractory Base

LB-96794

1

LB-96797

1

6.

Grate

87L20

1

87L21

1

3

4

5

2

1

6

6

3

4

5

Models 36

Models 42

Содержание 36" and 42" Wood Burning Fireplaces BC-36/42

Страница 1: ...e service from your Superior fireplace system Keep this document in a safe place for future reference Before you start your first fire read this Care and Operations Manual carefully to be sure you und...

Страница 2: ...windows located near the fireplace Avoid using combustible flowing window treatments such as curtains on nearby windows that are of sufficient length to be blown in front of an open flame when the win...

Страница 3: ...e The higher the density the more potential heat output 4 4 8 Standard Cord of Wood Figure 1 6 Most wood needs to be seasoned 9 to 12 months to reduce the moisture content and produce good steady fire...

Страница 4: ...ack 39 SOFTWOODS DENSITY Bald cypress 46 Cedar 31 47 Douglas Fir 46 50 Fir 32 43 Hemlock 40 45 Larch Western 52 Pine 39 59 Redwood 35 40 Spruce 35 41 Tamarack 53 Figure 4 CAUTION IF A SMOKING CONDITIO...

Страница 5: ...laces but must not be operated if the complete system is not in stalled See Figure 5 and refer to Figure 2 If you have reason to believe that you do not have a complete outside combustion system conta...

Страница 6: ...y below free of excessive ashes The fire needs plenty of air movement around the logs 5 If smoking occurs an hour or two after lighting the fire perhaps your well insulated house is too airtight and t...

Страница 7: ...ides a forced air circulation feature for your appliance When installing the FBK 100 Blower Kit a Blower Switch Kit Model FUBSK is required This switch kit allows for a unit mounted blower switch to b...

Страница 8: ...discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 Models 36 Models 42 No DESCRIPTION Part No Qty Part No Qty G...

Отзывы: